1. Ifihan
This manual provides essential instructions for the safe installation, operation, and maintenance of your Wayne WST33 1/3 HP Submersible Thermoplastic Sump Pump. Please read this manual thoroughly before installation and retain it for future reference. Proper installation and adherence to these guidelines will ensure optimal performance and longevity of your sump pump.
2. Alaye Aabo
IKILO: Ikuna lati tẹle awọn ilana aabo wọnyi le ja si mọnamọna, ina, ipalara nla, tabi iku.
- Máa yọ agbára kúrò nínú píńpù kí o tó ṣe iṣẹ́ tàbí ìtọ́jú èyíkéyìí.
- Ensure the pump is connected to a properly grounded 120V AC GFCI (Ground Fault Circuit Interrupter) protected outlet.
- Ma ṣe ṣiṣẹ fifa soke pẹlu okun ti o bajẹ tabi plug.
- Do not use this pump for flammable or corrosive liquids. It is designed for water only.
- Keep hands and feet clear of the pump inlet and discharge openings when the pump is connected to power.
- Ma ṣe gbe fifa soke nipasẹ okun agbara rẹ.
- Ensure the sump basin is free of debris that could obstruct the pump or float switch.
3. Ọja Ipariview
The Wayne WST33 is a robust 1/3 HP submersible sump pump constructed from reinforced thermoplastic, designed for reliable water removal in sump applications. It features a piggyback tether float switch for automatic or manual operation and a unique top suction design to minimize clogging.
Awọn ẹya pataki:
- Agbara ẹṣin: 1/3 HP oil-filled motor.
- Ikole: Reinforced thermoplastic for durability.
- Yiyi leefofo loju omi: Piggyback tether float switch for automatic or manual control.
- Idena Clog: Unique top suction design reduces clogging and prevents air lock.
- Sisọ silẹ: 1.5-inch NPT discharge for standard plumbing connections.
- Okun Agbara: 8-foot waterproof power cord.
- Iṣiṣẹ: Energy-efficient operation with a maximum flow rate of 3000 GPH.

Figure 1: Wayne WST33 Submersible Sump Pump. This image displays the black, reinforced thermoplastic pump unit with its integrated handle, power cord, and piggyback tether float switch. The base of the pump shows the intake screen and the threaded discharge port.
4. Eto ati fifi sori
The WST33 sump pump is designed for straightforward installation, typically completed within 15 minutes. Follow these steps for proper setup:
- Sump Basin Igbaradi: Rii daju pe sump rẹ basin has a minimum diameter of 14 inches to accommodate the pump and allow for proper float switch operation. Clean the basin of any debris, gravel, or sediment.
- Ipo ti fifa soke naa: Gbe fifa soke sori oju ilẹ ti o lagbara, ti o tẹẹrẹ ni isalẹ sump basin. Avoid placing it directly on dirt or gravel, which could lead to clogging.
- Asopọ Paipu Isunjade: Connect a 1-1/2 inch NPT discharge pipe to the pump's outlet. It is recommended to use a check valve (not included) in the discharge line to prevent water from flowing back into the sump basin nígbà tí pọ́ọ̀ǹpù bá pa.
- Àtúnṣe Ìyípadà Lílefó: The piggyback tether float switch controls the pump's automatic operation. Adjust the tether length to achieve the desired ON and OFF levels. The recommended ON level is 14 inches and the OFF level is 7 inches. Ensure the float switch can move freely without obstruction by the pump, basin walls, or piping.
- Asopọ agbara: Plug the pump's 8-foot waterproof power cord into a dedicated 120V AC GFCI-protected electrical outlet. Do not use extension cords.
- Iṣiṣẹ Idanwo: Kún omi náà basin with water to verify the pump turns on and off correctly at the desired levels. Observe the discharge flow and ensure no leaks are present.
5. Isẹ
The Wayne WST33 sump pump can operate in two modes: automatic or manual, controlled by its piggyback tether float switch.
Isẹ aladaaṣe:
For automatic operation, plug the pump's power cord into the piggyback plug, and then plug the piggyback plug into the GFCI-protected outlet. The pump will automatically turn on when the water level rises to the float switch's ON level (approximately 14 inches) and turn off when the water level drops to the OFF level (approximately 7 inches).
Isẹ afọwọṣe:
To operate the pump manually, unplug the pump's power cord from the piggyback plug and plug the pump's power cord directly into the GFCI-protected outlet. The pump will run continuously until unplugged. Use manual operation for quick water removal or testing, but do not leave unattended for extended periods.
The unique top suction design helps prevent air lock conditions, ensuring consistent pumping performance.
6. Itọju
Regular maintenance ensures the efficient and reliable operation of your sump pump. Always disconnect power before performing any maintenance.
- Inspect Sump Basin: Lojoojumọ ṣayẹwo sump basin for accumulated debris, silt, or gravel. Clean the basin as needed to prevent pump obstruction.
- Ṣàyẹ̀wò Yíyípadà Líle: Ensure the float switch moves freely and is not obstructed by wires, pipes, or the basin walls. Manually lift the float to verify the pump activates.
- Ṣe ayẹwo Impeller: While the pump's top suction design reduces clogging, occasionally inspect the intake screen and impeller for any lodged debris. Clear any obstructions carefully.
- Ayẹwo okun agbara: Ṣe àyẹ̀wò okùn agbára náà fún àwọn àmì ìbàjẹ́, ìfọ́, tàbí ìgé. Rọpò rẹ̀ tí ó bá bàjẹ́.
- Awọn ayẹwo akoko: Perform more thorough checks before heavy rain seasons or after extended periods of inactivity.
7. Laasigbotitusita
If your Wayne WST33 sump pump is not operating as expected, refer to the following troubleshooting guide:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Fifa ko tan. | No power to the pump. Switifu omi ti dina tabi ti ko tọ. Apọju mọto. | Check GFCI outlet, circuit breaker. Ensure power cord is securely plugged in. Clear obstructions around float switch. Test float switch manually. Replace if faulty. Allow motor to cool. Check for impeller obstructions. |
| Fifa gbalaye continuously. | Float switch stuck in ON position. Ṣàyẹ̀wò àtètèjì tí kò ní àbùkù tàbí tí kò ní àbùkù. Continuous water inflow. | Clear obstructions around float switch. Adjust tether length. Replace if faulty. Install or replace check valve in discharge line. Identify and address source of excessive water inflow. |
| Pọ́ọ̀pù náà ń ṣiṣẹ́ ṣùgbọ́n kò yọ omi kúrò. | Discharge pipe clogged or frozen. Impeller dí. Air lock condition. | Inspect and clear discharge pipe. Ensure it's not frozen. Disconnect power, remove pump, and clear impeller/intake screen. The WST33's top suction design minimizes air lock, but ensure the pump is fully submerged and the discharge line is clear. |
| Pump jẹ ariwo pupọ. | Idoti ni impeller. Pump not sitting level. Worn bearings (less common for new pump). | Disconnect power and clear impeller. Ensure pump is on a stable, level surface. Contact customer support if noise persists and pump is new. |
Ti awọn igbesẹ laasigbotitusita ko ba yanju ọran naa, kan si atilẹyin alabara fun iranlọwọ siwaju.
8. Awọn pato
| Awoṣe | WST33 |
| Iru | Automatic Submersible Sump Pump |
| Ohun elo | Plumbing (Sump Water Removal) |
| Agbara ẹṣin | 1/3 HP (0.33 HP) |
| Voltage | 120 V |
| Ampigba | 9.5 A |
| Oṣuwọn Sisan ti o pọju | 3000 Galanu fun Wakati (GPH) |
| Flow Rate @ 10 ft. Head | 2130 GPH |
| Flow Rate @ 5 ft. Head | 2610 GPH |
| Flow Rate @ 15 ft. Head | 1404 GPH |
| Iwon Ifijiṣẹ | 1-1 / 2 inch NPT |
| Agbara Okun Ipari | 8 ẹsẹ |
| Iwọn | 9 iwon |
| Ohun elo ikole | Reinforced Thermoplastic |
| Ohun elo Impeller | Scratch resistant glass reinforced polycarbonate |
| Awọn ifọwọsi | cULus Agency, UL/CSA |
9. Atilẹyin ọja ati Support
Atilẹyin ọja to lopin:
The Wayne WST33 Sump Pump comes with a 2-odun lopin atilẹyin ọja from the date of purchase. This warranty covers defects in material and workmanship under normal use and service. For specific terms and conditions, please refer to the warranty documentation included with your product or contact the manufacturer.
Atilẹyin Onibara:
For technical assistance, warranty claims, or to order replacement parts, please contact Wayne customer support. Have your model number (WST33) and date of purchase ready when contacting support.
Contact information for Wayne customer support can typically be found on the product packaging or the manufacturer's official webojula.