Irawọ 025191

Ìwé Ìtọ́sọ́nà Olùlò Pọ́ọ̀ǹpù Adágún Oníṣẹ́-giga Star 025191

Awoṣe: 025191

Ọrọ Iṣaaju

Star 025191 High Performance Pool Pump, a black pump unit with a clear strainer lid and various connection ports.

Aworan: Star 025191 High Performance Pool Pump. This image displays the complete pool pump unit, highlighting its compact design and key components like the motor, pump housing, and transparent strainer lid.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Star 025191 High Performance Pool Pump. This pump is designed for use with in-ground or above-ground swimming pools up to 53,000 gallons, ensuring water clarity and hygiene. Please read this manual thoroughly before installation and operation.

The Star 025191 pump features a 1.5 HP single-speed motor, factory-wired for 230 Volts, and is constructed from corrosion-resistant thermoplastic for durability. It delivers a high volume flow rate of up to 110 GPM at 20’ TDH for efficient water circulation to filtration systems.

Awọn Itọsọna Aabo pataki

Nigbati o ba nfi sori ẹrọ ati lilo ohun elo itanna yii, awọn iṣọra aabo ipilẹ yẹ ki o tẹle nigbagbogbo, pẹlu atẹle naa:

  • Ka ati tẹle gbogbo awọn ilana.
  • IJAMBA: Risk of electrical shock. Connect only to a grounded receptacle protected by a ground-fault circuit interrupter (GFCI).
  • IKILO: Lati dinku eewu ipalara, ma ṣe gba awọn ọmọde laaye lati lo ọja yii.
  • IKILO: This pump is for permanent installation only. Do not use with storable pools.
  • Rí i dájú pé ìpèsè iná mànàmáná náà bá ìwọ̀n píńpù náà mutage requirements (115V or 230V). The pump is factory-wired for 230V.
  • All wiring must be performed by a qualified electrician and comply with local codes and regulations.
  • Always disconnect power to the pump before servicing or performing maintenance.
  • Do not operate the pump if it has been damaged in any way.
  • Keep all connections dry and away from water.

Package Awọn akoonu

Rí i dájú pé gbogbo àwọn èròjà wà nínú àpò náà kí o tó bẹ̀rẹ̀ sí í fi sori ẹ̀rọ náà.

Diagram showing the pool pump and its included accessories: two 2-inch slip union adapters, two 1.5-inch slip union adapters, and two couplings.

Aworan: Package Contents Diagram. This illustration details the main pump unit (A) and the included connection accessories: 2-inch slip union adapters (B), 1.5-inch slip union adapters (C), and couplings (D).

Awọn irinše to wa
NkanApejuweOpoiye
AStar 025191 Pool Pump1
B2" Slip Union Adapters2
C1.5" Slip Union Adapters2
DAwọn akojọpọ2

Eto ati fifi sori

Proper installation is crucial for the pump's performance and longevity. Refer to the installation diagram and follow these steps carefully.

1. Aye Yiyan

  • Install the pump as close to the pool as possible to minimize friction loss from long suction lines.
  • Ensure the pump is installed on a firm, level base that can support its weight and prevent vibration.
  • Provide adequate ventilation around the motor for cooling.
  • Protect the pump from excessive moisture and direct sunlight.

2. Plumbing Awọn isopọ

The pump is designed to connect to either 1.5-inch or 2-inch pipe using the included slip union adapters and couplings.

  1. Apply thread sealant to all threaded connections to ensure a watertight seal.
  2. Connect the appropriate slip union adapters (1.5" or 2") to the pump's inlet and outlet ports.
  3. Use the couplings to connect the pump to your existing pool plumbing. Ensure all connections are tight to prevent air leaks, especially on the suction side.
Diagram illustrating the installation of a pool pump with an in-ground pool, showing connections to the skimmer and return lines, and a performance table.

Aworan: Installation Diagram and Performance Data. This image provides a visual guide for connecting the pump to an in-ground pool system and includes a table detailing the pump's flow rate (GPM) at various Total Dynamic Head (TDH) levels.

3. Itanna Awọn isopọ

The Star 025191 pump is factory-wired for 230 Volts. If your electrical supply is 115 Volts, consult a qualified electrician for proper rewiring. The pump includes a 3 ft pigtail cord with ring terminals for connection.

  • Ensure the power supply is disconnected at the circuit breaker before making any electrical connections.
  • Connect the pump's pigtail cord to a dedicated circuit protected by a Ground-Fault Circuit Interrupter (GFCI).
  • All electrical connections must comply with national and local electrical codes.

Awọn ilana Iṣiṣẹ

1. Ṣíṣe àtúnṣe Pọ́ọ̀pù

Before starting the pump for the first time, or after the pump has been drained, it must be primed.

  1. Ensure the pool water level is adequate.
  2. Ṣí gbogbo àwọn fáfà ìfàmọ́ra àti ìpadàsẹ́yìn nínú ètò píìmù adágún.
  3. Remove the transparent strainer cover and fill the strainer basket housing with water until it overflows.
  4. Replace the strainer cover, ensuring it is securely tightened to prevent air leaks.
  5. Turn on the power to the pump. The pump should begin to draw water and expel air from the return lines.
  6. If the pump does not prime within 5 minutes, turn it off, re-prime, and check for air leaks in the suction line.

2. Isẹ deede

  • Once primed, the pump will operate continuously, circulating water through your filtration system.
  • Monitor the pressure gauge on your filter (if applicable) to ensure it is within the normal operating range. An unusually high pressure reading may indicate a dirty filter or blockage.
  • Regularly check the transparent strainer cover to see if the basket needs cleaning.

Itoju

Regular maintenance ensures optimal performance and extends the life of your pool pump.

1. Cleaning the Strainer Basket

The large strainer basket is designed to collect debris before it reaches the pump impeller. The transparent cover allows for easy visual inspection.

  1. Turn off the pump and disconnect power at the circuit breaker.
  2. Rotate the transparent strainer cover counter-clockwise to remove it.
  3. Gbe agbọn strainer jade ki o si ofo eyikeyi idoti ti a gba.
  4. Fi omi ṣan agbọn naa daradara.
  5. Inspect the O-ring on the strainer cover for cracks or wear. Replace if necessary.
  6. Place the clean basket back into the housing, ensuring it is seated correctly.
  7. Replace the strainer cover, tightening it clockwise until snug. Do not overtighten.
  8. Re-prime the pump as described in the "Operating Instructions" section.

2. Igba otutu

If you live in an area where temperatures drop below freezing, proper winterization is essential to prevent damage.

  • Pa fifa naa ki o si ge agbara kuro.
  • Drain all water from the pump by removing the drain plugs (if applicable) or by disconnecting plumbing.
  • Store the pump in a dry, protected area, or cover it securely if it must remain outdoors.

Laasigbotitusita

This section addresses common issues you might encounter with your pool pump. For problems not listed here, contact customer support.

IsoroOwun to le FaOjutu
Pump ko bẹrẹNo power; tripped circuit breaker/GFCI; faulty motor.Check power supply; reset breaker/GFCI; consult electrician.
Pump runs but does not prime or moves little waterAir leak in suction line; low water level; clogged strainer basket; closed valves.Check all connections for leaks; ensure adequate pool water level; clean strainer basket; open all valves.
Ariwo pupọ tabi gbigbọnAir leak; cavitation; worn bearings; debris in impeller.Check for air leaks; ensure proper water flow; contact service for worn parts.
Omi jijo lati fifaLoose connections; worn O-rings/seals; cracked housing.Tighten connections; replace O-rings/seals; contact service for housing damage.

Awọn pato

Detailed technical specifications for the Star 025191 High Performance Pool Pump.

Diagram showing the dimensions of the pool pump in inches, along with a table of specifications including weight, motor HP, Hertz, Volts, TagAmp, Phase, Discharge Size, Flow, Impeller Type, Cord Length, Cord Type, and Thermal Protection.

Aworan: Product Dimensions and Specifications. This image provides a detailed technical drawing with key dimensions of the pump and a table summarizing its electrical and performance characteristics.

SipesifikesonuIye
Nọmba awoṣe025191
Agbara ẹṣin (HP)1.5 HP
Motor IruIyara Nikan
Voltage115/230V (Factory wired for 230V)
Ipele1
Oṣuwọn Sisan (O pọju)110 GPM @ 20' TDH (6,000 GPH)
Ohun eloCorrosion-resistant Thermoplastic
Iwon Ifijiṣẹ1.5" or 2" (adapters included)
Okun Gigun3 ft pigtail with ring terminals
Gbona IdaaboboBẹẹni
Ìwò Mefa26.5" x 9.45" x 12.6"
IwọnIsunmọ 50 lbs (22.6 kg)
UPC054757100056

Atilẹyin ọja

The Star 025191 High Performance Pool Pump is covered by a 1-odun lopin atilẹyin ọja láti ọjọ́ tí a rà á. Àtìlẹ́yìn yìí bo àwọn àbùkù nínú àwọn ohun èlò àti iṣẹ́ ọwọ́ lábẹ́ lílo àti iṣẹ́ déédéé.

For warranty claims or to understand the full terms and conditions, please refer to the warranty card included with your product or contact Star Water Systems customer support.

Note: This product is not available for shipment to California.

Onibara Support

For technical assistance, replacement parts, or warranty inquiries, please contact Star Water Systems customer support.

  • Webojula: www.starwatersystems.com (Eksample ọna asopọ, ọna asopọ gangan le yatọ)
  • Foonu: Tọkasi apoti ọja rẹ tabi ti olupese webaaye fun awọn nọmba olubasọrọ lọwọlọwọ.

When contacting support, please have your model number (025191) and date of purchase readily available.

Awọn iwe aṣẹ ti o jọmọ - 025191

Ṣaajuview STAR Capella 2HCX Lifted Parts Manual - Comprehensive Component Guide
Detailed parts manual for the STAR Capella 2HCX Lifted utility vehicle. Find part numbers, descriptions, and specifications for all components, organized by system.
Ṣaajuview Star Two Sided Grills GX10, GX14, GX20 Series: Installation and Operation Manual
Comprehensive installation, operation, maintenance, and safety instructions for Star Two Sided Grills models GX10, GX14, and GX20 series. Includes electrical specifications, troubleshooting, and warranty information.
Ṣaajuview اطلاعات و بیانیه موافقت برای فرایند جهت‌دهی شغلی KAoA-STAR
راهنمای جامع برنامه KAoA-STAR برای جهت‌دهی شغلي DANsh‌آموزان BA NYAZAI نحوه اشتراک‌گذاری اطلاعات و فرم رضایت‌نامه والدین.
Ṣaajuview STAR Paragon Inflatable Kayak kika Ilana
Itọsọna igbese-nipasẹ-igbesẹ lori bi o ṣe le ṣe pọ daradara ati fipamọ STAR Paragon rẹ kayak inflatable fun gbigbe ati ibi ipamọ rọrun.
Ṣaajuview Montageanleitung für Star Waschbeckenunterschrank X9T Q5 705
Detaillierte Montageanleitung für den Star Waschbeckenunterschrank, Modell X9T Q5 705. Enthält Schritt-für-Schritt-Anweisungen, Teileliste ati wichtige Sicherheitshinweise fun fifi sori ẹrọ erfolgreiche.
Ṣaajuview Ìtọ́sọ́nà Ìṣètò Rọrùn Star mC-Print3: Sísopọ̀ mọ́ Àwọn Ẹ̀rọ
This guide provides step-by-step instructions for setting up the Star mC-Print3 printer. It covers checking supplied accessories, downloading the mC-Print3 utility, and connecting the printer to iOS, Android, Mac, Linux, and Windows devices via Bluetooth, USB, or Wired LAN. Includes troubleshooting tips and rear cover installation.