Beckett BK171UL

Beckett BK171UL Condensate Pump with Safety Switch User Manual

Model: BK171UL

1. Ifihan

This manual provides detailed instructions for the installation, operation, and maintenance of the Beckett BK171UL Condensate Pump. This pump is designed for automatic removal of condensate from HVAC equipment, including air conditioners, furnaces, boilers, dehumidifiers, and high-efficiency oil or gas-fired furnaces. It is suitable for condensate water temperatures up to 150°F and acidic condensate.

Beckett BK171UL Condensate Pump

Image 1.1: Beckett BK171UL Condensate Pump, front view.

2. Alaye Aabo

ÌKÌLỌ̀: Ewu Ìjayà Iná mànàmáná. Gé agbára náà kúrò kí o tó ṣiṣẹ́.

  • Ka gbogbo awọn ilana ni pẹkipẹki ṣaaju fifi sori ẹrọ ati ṣiṣẹ.
  • Rii daju pe ipese agbara ibaamu voltage (115V).
  • Ma ṣe ṣiṣẹ fifa soke pẹlu okun ti o bajẹ tabi plug.
  • Do not immerse the pump in water.
  • This pump is designed for indoor use only.
  • Jeki ọwọ kuro ninu gbigbe awọn ẹya lakoko iṣẹ.
  • Rii daju didasilẹ to dara gẹgẹbi awọn koodu itanna agbegbe.
  • The pump is equipped with a safety switch. Ensure it is correctly wired to prevent overflow.

3. Package Awọn akoonu

Daju pe gbogbo awọn paati wa ṣaaju ki o to bẹrẹ fifi sori:

  • Beckett BK171UL Condensate Pump unit
  • 3/8" O.D. barbed check valve
  • Integrated 6-ft grounded power cord
  • Ilana Afowoyi (iwe yii)
Bugbamu view of Beckett BK171UL Condensate Pump components

Aworan 3.1: exploded view showing pump components including cover, check valve, motor, fan, automatic switches, lift-to-test tab, bullseye level, floats, impeller, multi-slot metal mount tabs, 6 ft. grounded power cord, and collection tank.

4. Fifi sori ẹrọ ati Oṣo

4.1 Iṣagbesori fifa soke

The pump features stainless steel multi-slot mounting tabs for secure installation. Ensure the pump is placed on a level surface. Use the integrated bullseye level on the lid to confirm proper horizontal alignment.

Beckett BK171UL Condensate Pump installation features

Image 4.1: Close-up of pump showing bullseye level, twist lock check valve, and lift-to-test tab for easy installation and maintenance.

4.2 Condensate Inlet Connections

The pump is equipped with four 1-1/8-inch diameter inlet holes for connecting condensate drain lines from your HVAC equipment. Connect the drain line(s) to any available inlet(s).

4.3 Discharge Line Connection

Connect a 3/8" I.D. vinyl tubing (not included) to the 3/8" O.D. barbed check valve. The check valve twists to lock into place on the pump, preventing backflow of discharged water. Route the discharge line to an appropriate drain, ensuring it has a continuous downward slope and is free from kinks or obstructions. The pump can lift water up to 17 feet vertically.

4.4 Itanna Asopọ

Plug the 6-ft grounded power cord into a standard 115V electrical outlet. Ensure the outlet is properly grounded and protected by a ground fault circuit interrupter (GFCI) if required by local codes.

4.5 Safety Switch Wiring

The integrated safety switch is designed to shut down the HVAC equipment or trigger an alarm in case of a pump malfunction or high water level, preventing overflow. Consult your HVAC equipment manual for proper wiring of the safety switch. Typically, the safety switch wires are connected in series with the low-voltage thermostat circuit of the HVAC unit.

5. Isẹ

5.1 Automatic On/Off Operation

The Beckett BK171UL pump operates automatically. When condensate water in the collection tank reaches a predetermined level, the pump will activate, remove the water, and then shut off once the water level drops. This automatic cycle ensures efficient condensate removal without constant monitoring.

Beckett BK171UL Condensate Pump performance chart

Image 5.1: Diagram illustrating automatic ON/OFF operation and average performance at various lift heights (e.g., 95 GPH at 5 ft lift, 64 GPH at 10 ft lift, 17 ft shut-off).

5.2 Lift-to-Test Function

A "lift-to-test" tab is provided on the pump lid. Lifting this tab manually raises the float, simulating a high water level and activating the pump. This feature allows for quick testing of the pump's functionality and can also be used to drain the tank for servicing.

6. Itọju

Regular maintenance ensures optimal performance and extends the life of your condensate pump.

  • Ayẹwo oṣooṣu: Visually inspect the pump, inlet, and discharge lines for any blockages, leaks, or damage. Ensure the discharge line is free of kinks.
  • Ìmọ́tótó mẹ́ẹ̀dọ́gbọ̀n:
    1. Disconnect power to the pump and the HVAC unit.
    2. Use the lift-to-test tab to drain the tank, or manually remove any remaining water.
    3. Carefully remove the pump cover.
    4. Clean the collection tank, floats, and impeller area to remove any sludge, debris, or mineral deposits. A mild detergent and soft brush can be used.
    5. Fi omi mímọ́ wẹ gbogbo awọn eroja naa daradara.
    6. Reassemble the pump, ensuring the cover is securely in place.
    7. Reconnect power and test the pump using the lift-to-test tab.
  • Laini Ìtújáde: Periodically check the discharge line for algae or mineral buildup, especially if the pump is handling acidic condensate. Clean or replace the tubing as necessary.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Pump ko ṣiṣẹKo si agbara si fifa sokeCheck power cord connection, circuit breaker, and GFCI.
Float switch stuck or obstructedDisconnect power, remove cover, clean floats and tank.
Pump runs but does not discharge waterDischarge line clogged or kinkedInspect and clear the discharge line. Ensure no kinks.
Check valve obstructedDisconnect power, remove and clean the check valve.
Impeller díDisconnect power, remove cover, clean impeller area.
Fifa gbalaye continuouslySwitifu omi ti di ipo "titan" muDisconnect power, remove cover, clean floats and tank.
Leak in discharge line or check valveInspect all connections and the discharge line for leaks. Tighten or replace as needed.
Pump jẹ alariwoDebris in impeller or motorDisconnect power, remove cover, clean impeller area.
Fifa ko ipeleAdjust pump placement using the bullseye level.

8. Awọn pato

  • Awoṣe: BK171UL
  • Voltage: 115V
  • Maximum Lift: 17 ft
  • Oṣuwọn Sisan: 112 GPH @ 1 ft lift
  • Ampigba: 1.1 Amps
  • Wattage: 60 Wattis
  • Igbohunsafẹfẹ: 60 HZ
  • Agbara Apoti Gbigba: 2.5 mẹẹdogun
  • Asopọ sisilẹ: 3/8" O.D. barbed check valve
  • Awọn isopọ ti nwọle: Four 1-1/8" diameter holes
  • Okun Agbara: 6 ft grounded with plug
  • Maximum Condensate Water Temperature: 150°F
  • Ohun elo: Acrylonitrile Butadiene Styrene (ABS), Ṣiṣu
  • Awọn iwọn (L x W x H): 11.2" x 5.2" x 6.6"
  • Ìwọ̀n Nkan: 3.7 iwon
  • Awọn ẹya Aabo: Integrated safety switch, Thermally protected motor
  • Awọn iwe-ẹri: UL/cUL listed in U.S./Canada
Beckett BK171UL Condensate Pump dimensions

Image 8.1: Dimensions of the Beckett BK171UL Condensate Pump.

9. Atilẹyin ọja ati Support

The Beckett BK171UL Condensate Pump comes with a 3-odun olupese atilẹyin ọja. For warranty claims, technical assistance, or replacement parts, please contact Beckett Corporation customer support. Keep your purchase receipt as proof of purchase.

For further assistance, please refer to the official Beckett Corporation webojula tabi kan si wọn onibara iṣẹ Eka.

Awọn iwe aṣẹ ti o jọmọ - BK171UL

Ṣaajuview Beckett CB22 Pump Condensate Aifọwọyi: Fifi sori ẹrọ, Iṣẹ-ṣiṣe & Itọsọna Aabo
Iwe afọwọkọ oniwun okeerẹ fun Ẹka Condensate Aifọwọyi Beckett CB22. Pẹlu awọn ilana alaye fun fifi sori ẹrọ, iṣẹ ailewu, wiwu, itọju, laasigbotitusita, ati alaye atilẹyin ọja to lopin.
Ṣaajuview Beckett BK17/BK22 Condensate Yiyọ Pump Fi sori ẹrọ ati Itọsọna Itọju
Itọsọna yii pese alaye fifi sori ẹrọ, itọju, ati awọn ilana aabo fun Beckett BK17 ati awọn ifasoke condensate BK22, pẹlu alaye atilẹyin ọja ati awọn pato iṣẹ ṣiṣe.
Ṣaajuview Beckett Automatic Condensate Removal Pump Installation and Operation Manual
This manual provides comprehensive installation, operation, wiring, testing, and troubleshooting guidance for Beckett Automatic Condensate Removal Pumps, including models CL201UL, CL202UL, CL202ULHT, and CL202CE. It details warranty information and maintenance procedures.
Ṣaajuview Beckett AquaSmart 7600 Boiler Control Quick Reference Guide
A concise quick reference guide for the Beckett AquaSmart 7600 Series boiler control, covering technical specifications, installation, basic programming, and wiring diagrams, along with warranty information.
Ṣaajuview Beckett AquaSmart Awoṣe 7600 To ti ni ilọsiwaju Iṣakoso igbomikana fifi sori ati Afowoyi isẹ
Itọsọna okeerẹ fun eto iṣakoso igbomikana Beckett AquaSmart 7600, fifi sori ibora, wiwu, siseto, awọn ẹya bii HeatManager ™, ati laasigbotitusita fun ibugbe ati awọn ohun elo iṣowo ina.
Ṣaajuview Beckett AquaSmart 7610 igbomikana Iṣakoso: ọja Dì & ni pato
Iwe ọja okeerẹ fun Beckett AquaSmart 7610 Iṣakoso igbomikana. Awọn ẹya alaye, awọn anfani, iṣẹ ṣiṣe HeatManager™, atunto alailowaya iyan, alaye pipaṣẹ, awọn aworan onirin, awọn iwọn itanna, awọn pato iwọn otutu, ati awọn iwọn ayika. Pẹlu awọn nọmba apakan fun awọn sensọ ati awọn ẹya ẹrọ.