APC BVX2200LI-IN

APC 2200VA Line Interactive UPS BVX2200LI-IN User Manual

Model: BVX2200LI-IN

1. Ifihan

This manual provides essential instructions for the safe and efficient use of your APC 2200VA Line Interactive UPS, model BVX2200LI-IN. Please read this manual thoroughly before installation and operation to ensure proper functionality and to prevent damage to the unit or connected equipment. Keep this manual for future reference.

Iwaju view of the APC 2200VA Line Interactive UPS BVX2200LI-IN

olusin 1: Iwaju view of the APC 2200VA Line Interactive UPS BVX2200LI-IN. This image displays the front panel of the UPS, featuring the power button, status indicators, and a USB charging port.

2. Alaye Aabo

Observe the following safety precautions to reduce the risk of electric shock, fire, or injury:

3. Eto ati fifi sori

3.1 Unpacking ati ayewo

Carefully unpack the UPS and inspect it for any shipping damage. If any damage is found, notify the carrier and your dealer. The package should contain the UPS unit and this user manual.

3.2 batiri Asopọ

Before initial use, the internal battery must be connected. Refer to the diagram below for detailed steps:

Diagram showing steps to connect the battery connector for APC UPS

Figure 2: BVX Start-up Settings - Battery Connection. This diagram illustrates the four steps to properly connect the internal battery: pull, rotate, push, and lock the yellow battery connector into its seating.

  1. Pull the battery connector from its seating.
  2. Rotate the battery connector.
  3. Push the battery connector into the slot until it locks in position.
  4. Once locked, the battery connector is ready-to-use.

3.3 Connecting to Power and Devices

Connect the UPS power cord directly into a wall outlet. Note that this UPS requires a 3-pin 16A adapter or a 16A 3-pin power outlet due to its larger plug size. Connect your computer, monitor, router, and other critical electronic devices to the outlets on the rear of the UPS.

Ẹyìn view of the APC 2200VA Line Interactive UPS showing power outlets and connections

olusin 3: Ẹyìn view of the APC 2200VA Line Interactive UPS. This image shows the back panel of the UPS, including multiple power outlets for connecting devices, the input power cord, and the battery connector port.

4. Isẹ

4.1 Títẹ̀ sí UPS

Press the POWER ON/OFF button on the front panel to turn on the UPS. The green Power ON LED will illuminate, confirming that the UPS is operational and providing protection.

The UPS battery charges to full capacity during the first 24 hours while connected to utility power. The UPS will charge the battery whether it is turned on or off. Do not expect the battery to provide its full rated backup time during this initial charging period.

4.2 Pa UPS

Press and hold the POWER ON/OFF button for more than 2 seconds to turn off the UPS. A 2-second delay is incorporated to prevent accidental power-off.

4.3 Aifọwọyi VoltagIlana (AVR)

The Line Interactive UPS features Automatic Voltage Regulation (AVR). This function automatically corrects minor voltage fluctuations (sags and surges) without switching to battery power, thereby preserving battery life and ensuring a stable power supply to connected devices.

4.4 Okun gbigba agbara USB

The front panel includes a USB charging port (5V 2A) for convenient charging of mobile devices, even during a power outage when the UPS is operating on battery power.

APC UPS charging a smartphone on a desk next to a computer

Figure 4: UPS with USB Charging. This image shows the APC UPS on a desk, with a smartphone connected to its front USB port for charging, demonstrating its utility for mobile devices.

5. Itọju

5.1 batiri Itọju

The UPS contains a sealed lead-acid battery with an average expected life of 5 years under normal operating conditions. Factors such as frequent power outages, high temperatures, and deep discharges can reduce battery life. It is recommended to periodically test the UPS by simulating a power outage to ensure the battery is functioning correctly.

5.2 Ninu

To clean the exterior of the UPS, disconnect it from the power source and use a soft, dry cloth. Do not use liquid or aerosol cleaners, as they may contain flammable substances or cause electrical shock.

5.3 Ayika Awọn ipo

Operate the UPS in a clean, dry, and well-ventilated area. Avoid placing it near windows or in environments with high humidity, extreme temperatures, or direct sunlight, as these conditions can negatively impact performance and battery longevity.

6. Laasigbotitusita

If the UPS is not operating correctly, consult the following table for common issues and solutions:

IsoroOwun to le FaOjutu
UPS ko ni tan.Batiri ko sopọ tabi gba silẹ.Ensure the internal battery connector is fully seated. Plug the UPS into a wall outlet and allow it to charge for at least 24 hours.
Akoko afẹyinti kukuru.Battery not fully charged or nearing end of life. Overloaded UPS.Allow the UPS to charge for 24 hours. Reduce the load on the UPS. If the battery is old, consider replacement.
Continuous beeping with no lights.Indicates a potential battery failure or critical internal fault.Disconnect all loads and turn off the UPS. Contact APC customer support for assistance.
UPS not providing power to outlets.Circuit breaker tripped. UPS is off.Check the circuit breaker on the rear of the UPS and reset if tripped. Ensure the UPS is turned on.

7. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
BrandAPC
Nọmba awoṣeBVX2200LI-IN
Agbara2200VA
IruLine Interactive Soke
Iṣagbewọle Voltage2200 Volts (Orúkọ)
Batiri IruAcid Lead ti a ti di
Igba agbara BatiriWákàtí mẹ́jọ (sí 90% agbára)
Apapọ batiri Lifeọdun meji 5
Awọn iwọn Ọja (LxWxH)14 x 39 x 19 cm
Iwọn Nkan12.2 kg
Fọọmù ifosiweweAgbeko
Àwọ̀Dudu
Ilu isenbaleChina

Note: While the specifications list "Rack" form factor, the product images and typical usage for this model suggest a tower form factor.

8. Atilẹyin ọja ati Support

This APC UPS is manufactured by Schneider Electric. For detailed warranty information, product registration, and technical support, please visit the official APC by Schneider Electric webojula tabi kan si wọn onibara iṣẹ Eka.

When contacting support, please have your model number (BVX2200LI-IN) and serial number ready. Be aware that customer support availability may vary, and it is advisable to check their operating hours for prompt assistance.

Manufacturer: APC, SCHNEIDER ELECTRIC, 1,2.3,4 BUILDINC WORKSHOP, HENGCHANCRONC INDUSl'RIAL PARK, SHILONC COMMUNIl'Y STIIYAN 51'RI'I]T. BAOAN DISTRICT' SHENZFIEN. CHINA 5 I 8I08