1. Ifihan
This manual provides essential information for the installation, operation, and maintenance of your Daikin ARXC35C ATXC35C Inverter Air Conditioner. Please read this manual thoroughly before using the unit to ensure proper function and to prevent damage or injury. Keep this manual for future reference.
2. Alaye Aabo
Always observe the following safety precautions to reduce the risk of electric shock, fire, or injury.
- Fifi sori Ọjọgbọn: Installation, relocation, and maintenance of this unit must be performed by a qualified service technician. Improper installation can lead to electric shock, fire, or water leakage.
- Aabo Itanna: Ensure the power supply matches the unit's specifications. Do not operate with wet hands. Never attempt to repair or modify the unit yourself.
- Imudani firiji: The unit uses R32 refrigerant. This refrigerant is mildly flammable. Ensure proper ventilation during installation and servicing. Do not puncture or burn the refrigerant circuit.
- Awọn ọmọde ati Awọn eeyan Alailagbara: Ohun elo yii le ṣee lo nipasẹ awọn ọmọde ti o jẹ ọdun 8 ati ju bẹẹ lọ ati awọn eniyan ti o dinku ti ara, ifarako tabi awọn agbara ọpọlọ tabi aini iriri ati imọ ti wọn ba ti fun wọn ni abojuto tabi itọnisọna nipa lilo ohun elo ni ọna ailewu ati loye awọn eewu ti o kan. . Awọn ọmọde ko gbọdọ ṣere pẹlu ohun elo naa. Ninu ati itọju olumulo ko le ṣe nipasẹ awọn ọmọde laisi abojuto.
- Iyọkuro: Ṣe ìpamọ́ tó yẹ ní àyíká àwọn ẹ̀rọ inú ilé àti lóde kí afẹ́fẹ́ má baà máa lọ dáadáa àti kí a máa tọ́jú rẹ̀.
3. Ọja Ipariview
The Daikin ARXC35C ATXC35C is a split-system air conditioner designed for efficient cooling and heating. It consists of an indoor unit (ARXC35C) and an outdoor unit (ATXC35C).
Indoor Unit (ARXC35C)

Figure 3.1: Daikin ARXC35C Indoor Unit. This image shows the white, sleek indoor unit of the Daikin air conditioner, typically mounted high on a wall, with its front panel closed.
Outdoor Unit (ATXC35C)

Figure 3.2: Daikin ATXC35C Outdoor Unit. This image displays the beige-colored outdoor unit with a large fan grille, typically placed outside the building, responsible for heat exchange.
4. Eto ati fifi sori
Installation of the Daikin ARXC35C ATXC35C air conditioner requires specialized tools and knowledge. It is mandatory to have the unit installed by a certified HVAC professional to ensure safety, optimal performance, and warranty validity.
Awọn ero fifi sori ẹrọ bọtini:
- Ibi: Choose a location for both indoor and outdoor units that allows for proper airflow, minimal obstruction, and easy access for maintenance. Avoid direct sunlight or heat sources for the outdoor unit.
- Asopọmọra itanna: Rii daju pe Circuit agbara pataki kan wa pẹlu vol to yẹtage (240V) and circuit breaker protection is available.
- Pipa omi firiji: The unit comes pre-charged with R32 refrigerant for up to 7 meters of piping. For longer runs, additional refrigerant must be added by a professional.
- Sisan omi: Dídá omi tó yẹ fún omi tó ń dì omi láti inú ẹ̀rọ inú ilé ṣe pàtàkì láti dènà ìbàjẹ́ omi.
Refer to the detailed installation manual provided with the unit for specific instructions, diagrams, and safety warnings for installers.
5. Awọn ilana Iṣiṣẹ
Your Daikin ARXC35C ATXC35C air conditioner is controlled via a wireless remote control (not pictured). Familiarize yourself with the remote control's buttons and display.
Isẹ ipilẹ:
- Titan/Apapa: Tẹ awọn TAN/PA bọtini lati bẹrẹ tabi da kuro.
- Aṣayan Ipo: Lo awọn MODE bọtini lati yiyi nipasẹ awọn ipo iṣẹ:
- Itura: Fun itutu agbaiye yara.
- gbigbona: Fun alapapo yara naa (iṣẹ fifa ooru).
- FAN: Circulates air lai itutu tabi alapapo.
- GBE: Dehumidifies the room.
- LATIO: Laifọwọyi yan itutu agbaiye tabi alapapo da lori iwọn otutu yara.
- Atunṣe iwọn otutu: Lo awọn TẸMP▲ / ▼ awọn bọtini lati ṣeto iwọn otutu ti o fẹ.
- Iyara Olufẹ: Tẹ awọn FAN bọtini lati ṣatunṣe awọn àìpẹ iyara (Aifọwọyi, Low, Alabọde, Ga).
- Wiwa: Lo awọn WIPE button to adjust the airflow direction.
- Iṣẹ Aago: Set the unit to turn on or off automatically at specified times using the Aago ON/PA awọn bọtini.
Awọn ẹya pataki:
- Imọ ọna ẹrọ oluyipada: The inverter compressor adjusts its speed to maintain a stable temperature, leading to energy savings and quieter operation.
- Ipo Alagbara: Pese itutu agbaiye tabi alapapo fun igba diẹ.
- Ipo aje: Reduces power consumption for energy-efficient operation.
- Isẹ idakẹjẹ: Selectable fan settings for reduced noise levels.
6. Itọju
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always turn off the power supply to the unit before performing any maintenance.
Itọju olumulo:
- Fifọ Afẹfẹ: Clean the air filters every two weeks or more frequently depending on usage and air quality. Open the front panel of the indoor unit, remove the filters, wash them with water, dry thoroughly, and reinsert.
- Ìmọ́tótó Ìta Ẹ̀yà: Wipe the indoor and outdoor unit exteriors with a soft, damp cloth. Do not use harsh detergents, solvents, or abrasive cleaners.
Itọju Ọjọgbọn:
It is recommended to have a qualified technician perform a comprehensive service check at least once a year. This includes:
- Checking refrigerant levels and leaks.
- Cleaning the outdoor unit coils.
- Ṣiṣayẹwo awọn asopọ itanna.
- Checking drainage system.
7. Laasigbotitusita
Ṣaaju ki o to kan si iṣẹ, tunview awọn oran ti o wọpọ wọnyi ati awọn solusan ti o pọju wọn.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹka ko ṣiṣẹ | No power; Remote control batteries low; Timer set to OFF. | Check power supply/circuit breaker; Replace remote batteries; Cancel timer setting. |
| Insufficient itutu / alapapo | Dirty air filters; Doors/windows open; Temperature setting incorrect; Obstruction to airflow. | Clean air filters; Close doors/windows; Adjust temperature; Remove obstructions. |
| Ariwo ti ko wọpọ | Àwọn ẹ̀yà ara tí ó rọ̀; Ẹyọ kan kò ní ìpele; Àwọn ohùn ìṣiṣẹ́ déédé (fún àpẹẹrẹ, ìṣàn omi inú fìríìjì). | Check for loose parts (contact professional); Ensure unit is level; If noise is excessive or unusual, contact service. |
| Omi jijo lati inu ile kuro | Clogged sisan okun; Aibojumu fifi sori. | Contact a qualified technician to inspect and clear the drain hose or re-evaluate installation. |
If the problem persists after attempting these solutions, or if an error code appears on the display, contact a qualified Daikin service technician for assistance. Do not attempt to repair the unit yourself.
8. Awọn pato
The following table outlines the key technical specifications for the Daikin ARXC35C ATXC35C air conditioner.
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | Daikin |
| Nọmba awoṣe | ARXC35C (Indoor), ATXC35C (Outdoor) |
| Agbara Itutu | 12000 BTU |
| Energy Efficiency (Cooling) | A++ |
| Energy Efficiency (Heating) | A+ |
| Iru Refrigerant | R32 |
| Voltage | 240 folti |
| Wattage | 3530 W |
| Ọna fifi sori ẹrọ | Pin System |
| Pataki Awọn ẹya ara ẹrọ | Inverter konpireso |
| Package Mefa | 92 x 83 x 35 cm |
| Iwọn Nkan | 40.3 kg |
| SEER (Ipin Iṣiṣẹ Agbara Igbala) | 5 |
9. Atilẹyin ọja ati Support
Your Daikin ARXC35C ATXC35C air conditioner is covered by a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and retailer. Please refer to the warranty card included with your product or contact your point of purchase for detailed information.
For technical support, service requests, or inquiries regarding your unit, please contact Daikin customer service or an authorized Daikin service center. Ensure you have your model number (ARXC35C ATXC35C) and purchase details available when contacting support.
You can find contact information for Daikin support on their official website or through your local Daikin distributor.