Pedrollo PKm60220

PERIPHERAL BOOSTER WATER PUMP

Model: PKm60220

Brand: Pedrollo

Ọrọ Iṣaaju

This manual provides essential information for the safe and efficient operation and maintenance of your Pedrollo PKm60 Peripheral Booster Water Pump. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and to prevent injury or damage.

The Pedrollo PKm60 pump is designed for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the pump's materials. It is ideal for domestic use, including water distribution in combination with small pressure sets and for garden and allotment irrigation. For optimal performance and longevity, the pump should be installed in an enclosed environment or at least sheltered from inclement weather.

Alaye Aabo

IKILO: Ikuna lati tẹle awọn ilana aabo wọnyi le ja si mọnamọna, ina, ipalara nla, tabi iku.

Ọja Pariview

The Pedrollo PKm60 is a reliable peripheral booster pump designed for efficient water handling in domestic applications. Its compact design and robust construction ensure long-term performance.

Pedrollo PKm60 Peripheral Booster Water Pump

olusin 1: Iwaju-ẹgbẹ view of the Pedrollo PKm60 Peripheral Booster Water Pump. The pump is blue with a black motor housing and a red pressure relief valve. It features a 1-inch NPT inlet and outlet.

Awọn ẹya pataki:

Eto ati fifi sori

Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a qualified professional.

  1. Ibi: Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures. An enclosed environment is ideal.
  2. Iṣagbesori: Securely mount the pump on a stable, level surface using appropriate fasteners. Ensure there is sufficient space around the pump for ventilation and maintenance access.
  3. Awọn isopọ Pipin:
    • Connect the suction pipe to the pump's inlet (typically marked "IN" or with an arrow pointing towards the pump). Ensure the suction pipe is airtight to prevent air leaks, which can cause the pump to lose prime.
    • Connect the discharge pipe to the pump's outlet (typically marked "OUT" or with an arrow pointing away from the pump).
    • Use appropriate fittings (1 inch NPT) and sealants to ensure leak-free connections. Avoid putting strain on the pump's connections from the piping.
    • Fi àtọwọdá ẹsẹ kan sori ẹrọ kan pẹlu strainer ni opin paipu mimu ni orisun omi lati ṣe idiwọ idoti lati wọ inu fifa soke ati lati ṣetọju nomba.
  4. Asopọmọra itanna:
    • Ensure the power supply matches the pump's requirements (220V 60Hz).
    • Connect the pump to a dedicated circuit protected by a circuit breaker or fuse of appropriate rating.
    • Verify proper grounding to prevent electrical hazards.
  5. Fifi soke fifa soke: Before initial operation, the pump must be primed.
    • Remove the priming plug (usually located on the top of the pump casing).
    • Kun fifa casing patapata pẹlu omi mimọ titi yoo fi ṣàn.
    • Rọpo plug alakoko ni aabo.
    • Open any valves on the suction and discharge lines.

Awọn ilana Iṣiṣẹ

Nígbà tí a bá ti fi sori ẹrọ tí a sì ti ṣe àtúnṣe rẹ̀, fifa omi náà ti ṣetán fún iṣẹ́.

  1. Ibẹrẹ Ibẹrẹ: After priming, connect the pump to the power supply. The pump should start immediately and begin pumping water.
  2. Abojuto:
    • Observe the pump during the first few minutes of operation for any unusual noises, vibrations, or leaks.
    • Check the pressure gauge (if installed) to ensure the pump is operating within its specified working pressure range (6 bar for PK 60).
    • Ensure a steady flow of water. If the pump runs without delivering water, shut it off immediately to prevent damage from dry running. Re-prime the pump.
  3. Ise Tesiwaju: The pump is designed for continuous duty within its specified performance limits. Avoid operating the pump outside these limits.
  4. Paade: To turn off the pump, disconnect it from the power supply. If the pump will be out of use for an extended period, especially in cold weather, follow the winterization procedures in the Maintenance section.

Itoju

Regular maintenance ensures the longevity and efficient operation of your Pedrollo pump.

Laasigbotitusita

This section outlines common issues and their potential solutions. Always disconnect power before troubleshooting.

IsoroOwun to le FaOjutu
Pump ko bẹrẹ.No power, tripped circuit breaker, faulty wiring, seized impeller.Check power supply, reset breaker, inspect wiring (by qualified person), check for obstructions in impeller.
Fifa gbalaye sugbon ko si omi tabi kekere sisan.Pump not primed, air leak in suction line, clogged foot valve/strainer, low water level in source, discharge valve closed.Re-prime pump, check suction line for leaks, clean foot valve/strainer, ensure adequate water in source, open discharge valve.
Fifa jẹ alariwo tabi gbigbọn pupọ.Air in pump/suction line, cavitation, loose mounting, worn bearings.Re-prime pump, check for air leaks, ensure adequate water supply, tighten mounting bolts, contact service for bearing issues.
Yiyi fifa soke tan ati pa nigbagbogbo.Pressure switch malfunction, small leak in system, waterlogged pressure tank (if applicable).Inspect pressure switch, check for leaks in plumbing, inspect pressure tank.

Awọn pato

Detailed technical specifications for the Pedrollo PKm60 Peripheral Booster Water Pump.

ParamitaIye
Nọmba awoṣePKm60220
OlupesePEDROLLO
Olomi IruOmi mimọ
Orisun agbaraAC/DC (220V 60Hz)
Agbara ẹṣin0.5 HP
Oṣuwọn Sisan (O pọju)11 GPM (Gọọnu Fun Iṣẹju kan)
Head (Max)130 ft.
Liquid otutu Range-10 °C si +60 °C
Ambient Temperature (Max)+40 °C (+50 °C for PK 60)
Manometric Suction Lift (Max)8 m
Working Pressure (PK 60)6 igi
Awọn isopọ Inlet/Ijade1 inch x 1 inch NPT
Iwọn Nkan13 iwon
Ọja Mefa12 x 8 x 8 inches
Performance Curves for Pedrollo PKm60 and PKm65 Pumps

Figure 2: Performance curves illustrating the relationship between Head (ft.) and Flow rate (GPM) for Pedrollo PKm60 and PKm65 pumps. The PKm60 curve shows a maximum flow rate of approximately 11 GPM at 20 ft. head and a maximum head of 130 ft. at 0 GPM.

Atilẹyin ọja ati Support

Warranty information for your Pedrollo PKm60 pump is typically provided at the time of purchase or included with the product packaging. Please refer to your purchase documentation for specific warranty terms and conditions.

For technical support, spare parts, or service inquiries, please contact Pedrollo customer service or an authorized Pedrollo dealer. Ensure you have your pump's model number (PKm60220) and serial number (if applicable) ready when contacting support.

Awọn iwe aṣẹ ti o jọmọ - PKm60220

Ṣaajuview Pedrollo PRESFLO MULTI Automatic Control Device - Technical Specifications
Detailed technical specifications, installation guide, and features of the Pedrollo PRESFLO MULTI automatic electronic pressure control device for domestic water supply and pressure boosting.
Ṣaajuview Pedrollo PKm 60® Peripheral Impeller Pump - Technical Specifications and Performance
Detailed information on the Pedrollo PKm 60® peripheral impeller pump, including performance range, application limits, technical specifications, dimensions, and absorption data. Suitable for clean water transfer in domestic applications.
Ṣaajuview Pedrollo PV Series Peripheral Centrifugal Pumps with Brass Pump Body
Technical specifications, performance curves, and dimensions for Pedrollo PV series peripheral centrifugal pumps. Suitable for clean water in industrial applications like cooling and air conditioning. Features brass pump body, various motor options, and compliance with efficiency standards.
Ṣaajuview Pedrollo PKm 60 Electrobomb with Peripheral Impeller - Technical Data
Technical specifications, performance curves, and installation guidelines for the Pedrollo PKm 60 electro-pump with peripheral impeller. Suitable for clean water applications in domestic use.
Ṣaajuview Pedrollo PQ 3000 Peripheral Impeller Pumps - Technical Datasheet
Detailed technical specifications, performance curves, and construction features for the Pedrollo PQ 3000 and PQ 3000-MF peripheral impeller pumps, designed for clean water and industrial applications.
Ṣaajuview Pedrollo PQ Peripheral Impeller Pumps - Technical Specifications and Performance Data
Explore the Pedrollo PQ series of peripheral impeller pumps, designed for clean water applications in domestic and industrial settings. View detailed performance curves, technical specifications, dimensions, construction characteristics, absorption data, and palletization information.