1. Ifihan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo 3CRm80 Multi-stage Centrifugal Water Pump. Please read this manual thoroughly before installation and use, and retain it for future reference.
The Pedrollo 3CRm80 is a single-phase, multi-stage centrifugal pump designed for handling clean water and non-aggressive liquids. It is suitable for domestic applications such as water distribution in pressure systems and garden irrigation.
2. Alaye Aabo
Always observe the following safety precautions to prevent personal injury and damage to the pump:
- Ensure the pump is installed in a well-ventilated, enclosed area, protected from adverse weather conditions.
- Verify that the electrical supply matches the pump's voltage requirements (110V or 220V, 60Hz).
- Disconnect power before performing any installation, maintenance, or repair work.
- Do not operate the pump with flammable or corrosive liquids.
- Dáàbò bo fifa omi kuro ninu otutu otutu ti o tutu.
- Ensure proper grounding of the electrical connection.
3. Imọ ni pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awoṣe | 3CRm80 |
| Brand | Pedrollo |
| Iru | Olona-stage Centrifugal Water Pump |
| Agbara | 0.6 HP |
| Voltage | 110V or 220V AC, 60Hz (Single Phase) |
| O pọju Ori | Titi de 120ft (mita 36.5) |
| Oṣuwọn Sisan ti o pọju | Up to 1260 GPH (4769 liters/hour) |
| Iwọn Wiwọle / iṣan | 1 inch x 1 inch |
| Ohun elo | Irin ti ko njepata |
| Iwọn Nkan | 19 poun (isunmọ 8.6 kg) |
| Awọn iwọn (Apapọ) | 18 x 12 x 8 inches (iwọn 45.7 x 30.5 x 20.3 cm) |
| UPC | 722777873303 |

Nọmba 1: Pedrollo 3CRm80 Multi-stage Centrifugal Water Pump. This image displays the pump's stainless steel body and blue motor housing.

Nọmba 2: Performance Curve for Pedrollo CR series pumps. This graph illustrates the relationship between pump head (in meters and feet) and flow rate (in l/min and US g.p.m.) for various models, including the 3CRm80.
4. Eto ati fifi sori
4.1 Ipo
Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures. Ensure sufficient space around the pump for ventilation and maintenance.
4.2 Itanna Asopọ
- The pump operates on single-phase 110V or 220V AC, 60Hz. Verify your power supply matches the pump's requirements.
- Ensure the electrical circuit is protected by a suitable circuit breaker or fuse.
- Connect the pump to a properly grounded electrical outlet.
- The motor includes a thermal overload protector.
4.3 Plumbing Asopọ
- Connect 1-inch pipes to both the inlet and outlet ports of the pump.
- Use appropriate sealants (e.g., PTFE tape) on threaded connections to prevent leaks.
- Rii daju pe gbogbo awọn asopọ ti wa ni ṣinṣin ṣugbọn maṣe mu ju.
- Install a foot valve with a strainer on the suction line if drawing water from a well or tank to prevent debris from entering the pump and to maintain prime.
4.4 Priming fifa soke
Before initial operation, the pump must be primed. Remove the priming plug (usually located on the top of the pump casing) and fill the pump casing completely with clean water until it overflows. Replace the priming plug securely.
5. Awọn ilana Iṣiṣẹ
- Ensure the pump is properly installed and primed.
- Verify all plumbing connections are secure and leak-free.
- Connect the pump to the appropriate electrical power supply.
- Turn on the power. The pump should start operating and begin to move water.
- Monitor the pump for any unusual noises or vibrations during initial operation.
- If the pump fails to deliver water after a short period, turn off the power, re-prime the pump, and check for any obstructions in the suction line.
Awọn ohun elo
The Pedrollo 3CRm80 pump is suitable for:
- Irrigation systems for gardens and allotments.
- Water supply systems for domestic use.
- Integration with small and medium-sized pressure sets.
6. Itọju
Itọju deedee n ṣe idaniloju pe fifa rẹ yoo pẹ to ati pe yoo ṣiṣẹ daradara.
6.1 Gbogbogbo sọwedowo
- Lorekore ṣayẹwo fifa soke fun eyikeyi ami ti n jo, ipata, tabi ibajẹ.
- Ensure all electrical connections are secure and free from moisture.
- Check the suction line strainer (if installed) for blockages and clean as necessary.
6.2 Igba otutu
If the pump is installed in an area subject to freezing temperatures, it must be drained to prevent damage:
- Ge asopọ agbara si fifa soke.
- Open any drain plugs on the pump casing and plumbing lines.
- Jẹ́ kí gbogbo omi gbẹ tán pátápátá.
- Store the pump in a warm, dry place if possible, or ensure it is thoroughly drained and protected from freezing.
7. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ | No power; tripped circuit breaker; motor thermal overload activated. | Check power supply; reset circuit breaker; allow motor to cool down. |
| Pump runs but no water is delivered | Pump not primed; air leak in suction line; clogged suction strainer; insufficient water supply. | Re-prime the pump; check suction line connections; clean strainer; ensure adequate water source. |
| Ìṣàn omi tàbí ìfúnpá tí ó dínkù | Partial blockage in plumbing; worn impeller; air in system. | Inspect and clear plumbing; consult a qualified technician for impeller inspection; re-prime. |
| Ariwo pupọ tabi gbigbọn | Cavitation (air in pump); loose mounting; foreign object in pump. | Ensure pump is fully primed and suction is clear; tighten mounting bolts; disconnect power and inspect pump for obstructions (consult technician if unsure). |
8. Atilẹyin ọja ati Support
For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your authorized Pedrollo dealer. Keep your purchase receipt as proof of purchase.
Protection plans may be available for extended coverage. Please check with your retailer for details on 3-Year or 4-Year protection plans.
Manufacturer: Pedrollo
UPC: 722777873303