1. Ifihan
This manual provides detailed instructions for the safe and effective use of your KAIWEETS HT206B Clamp Meter and KAIWEETS KM100 Digital Multimeter. Please read this manual thoroughly before operation and retain it for future reference.
2. Alaye Aabo
WARNING: Always observe safety precautions when working with electrical circuits to prevent personal injury or damage to the meter.
- The HT206B meets safety standard IEC 61010-1, CAT III 600V. The KM100 has passed CE and RoHS certifications and is IEC rated CAT III 600V.
- Both devices feature anti-burn protection with double fuses and overload protection on all ranges (KM100).
- Ensure the rotary switch is set to the correct test range before making measurements.
- Ma ṣe gbiyanju lati wiwọn voltagawọn iṣan omi tabi awọn sisan omi ti o kọja awọn opin ti o pọju ti a sọ.
- Ṣe àyẹ̀wò àwọn ìdánwò ìdánwò fún ìbàjẹ́ kí o tó lò ó ní gbogbo ìgbà. Má ṣe lò ó tí ìdènà bá bàjẹ́.
- Nigbati idiwon lọwọlọwọ pẹlu clamp meter, only clamp the live wire, not the entire power cord.
3. Ọja Ipariview
3.1 KAIWEETS HT206B Clamp Mita

Figure 1: KAIWEETS HT206B Clamp Mita ati awọn ẹya ẹrọ ti o wa pẹlu.
The KAIWEETS HT206B is a True-RMS clamp meter designed for accurate measurements on non-linear loads. It is suitable for various applications in labs, factories, and households.
Awọn ẹya pataki:
- Awọn Agbara Iwọn: AC Current, AC/DC Voltage, Frequency, Duty Cycle, Resistance, Capacitance, Diode, Continuity, and Temperature.
- Two-color Backlit LCD Display: The screen turns red to warn of high voltage (>80V) or high current (>3A).
- Ina filaṣi LED: For illumination in dimly lit areas.
- Non-Olubasọrọ Voltage (NCV) Iwari: For detecting live wires without direct contact.
- Tiipa Aifọwọyi: A máa pa agbára lẹ́yìn ìṣẹ́jú márùn-ún tí a kò bá ṣiṣẹ́ láti fi pa batiri mọ́.
- Itọkasi Batiri Kekere: Àwọn ìkìlọ̀ nígbà tí àwọn bátírì bá nílò àyípadà.

Figure 2: HT206B Clamp Meter feature highlights.

Figure 3: NCV and Hold functions on the HT206B.
3.2 KAIWEETS KM100 Digital Multimeter

Figure 4: KAIWEETS KM100 Digital Multimeter and included accessories.
The KAIWEETS KM100 is a multi-function digital multimeter designed for safety and accuracy in various electrical tests, including household, automotive, and industrial applications.
Awọn ẹya pataki:
- Awọn Agbara Iwọn: AC/DC Voltage, DC Current, Resistance, Continuity, and Diode Measurement. Note: This model cannot test AC current.
- Iṣẹ ina ẹhin: Improves visibility in dark conditions.
- Iṣe idaduro: Locks the displayed measurement value for easy recording.
- Iduro Atilẹyin: Flexible and stable, adjustable up to 90°.
- Aabo: CAT III 600V, CE and RoHS certified, with anti-burn double fuses and overload protection.
4. Eto
4.1 Fifi sori batiri
Both the HT206B and KM100 require AAA batteries for operation.
- Wa ideri iyẹwu batiri ni ẹhin ẹrọ naa.
- Use a screwdriver (if necessary) to open the cover.
- Insert 2 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment. (For KM100, batteries are typically pre-installed).
- Rọpo ideri iyẹwu batiri ki o ni aabo.
4.2 So awọn itọsọna idanwo ati Thermocouple pọ
For most measurements, test leads are required. For temperature measurements with the HT206B, the K-Type thermocouple is used.
- Insert the red test lead into the "VΩmA" or "+" input jack.
- Insert the black test lead into the "COM" or "-" input jack.
- For HT206B temperature measurement, connect the K-Type thermocouple to the designated temperature input ports, observing polarity.
5. Awọn ilana Iṣiṣẹ
5.1 Gbogbogbo isẹ
- Turn the rotary switch to the desired measurement function.
- Connect the test leads or clamp the conductor as appropriate for the measurement.
- Ka iye wiwọn lori ifihan LCD.
- To turn off the device, rotate the switch to the "OFF" position. The HT206B also features automatic shutdown after 15 minutes of inactivity.
5.2 KAIWEETS HT206B Specific Operations
- AC Odiwọn lọwọlọwọ: Rotate the switch to the AC Current range (e.g., 6/60A or 600A). Open the clamp jaw and enclose only the live wire of the circuit. Ensure the jaw is fully closed.
- Bọ́tìnì. Press the "FUNC." button to switch between secondary functions within a range, such as AC and DC voltage, or different frequency/duty cycle modes.
- NCV (Non-Kan si Voltage) Iwari: Rotate the switch to the NCV position. Bring the top of the clamp meter near the conductor. The meter will beep and the NCV indicator will light up if AC voltage ti ri.
- Iṣe DIMU: Press the "MAX/MIN" button briefly to activate the data hold function, freezing the current reading on the display. Press again to release.
- Iwọn iwọn otutu: Connect the K-Type thermocouple. Rotate the switch to the temperature function (°C/°F). Insert the thermocouple probe into the substance or area to be measured.

Figure 5: HT206B temperature measurement applications.
5.3 KAIWEETS KM100 Specific Operations
- VoltagÌwọ̀n e (AC/DC): Rotate the switch to the desired AC V or DC V range. Connect test leads in parallel to the circuit.
- Diwọn DC lọwọlọwọ: Rotate the switch to the DC A range. Connect test leads in series with the circuit. Caution: Do not attempt to measure AC current with the KM100.
- Iwọn Atako: Rotate the switch to the Ω range. Connect test leads across the component to be measured. Ensure the circuit is de-energized.
- Idanwo Ilọsiwaju: Rotate the switch to the continuity/diode position. Connect test leads across the circuit or component. A continuous beep indicates continuity.

Figure 6: KM100 Continuity Test.

Figure 7: KM100 DC Voltage Idiwon.
6. Itọju
6.1 Ninu
Nu mita naa casing pẹlu ipolowoamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun tí ó ń yọ́ omi. Rí i dájú pé mita náà gbẹ kí o tó lò ó.
6.2 Batiri Rirọpo
Tí àmì bá hàn lórí ìbòjú, yí àwọn bátìrì padà kíákíá láti rí i dájú pé àwọn ìkà náà péye. Wo Apá 4.1 fún ìtọ́ni lórí bí a ṣe ń fi bátìrì sí.
6.3 Ibi ipamọ
When not in use for extended periods, remove the batteries to prevent leakage. Store the meters and accessories in their carrying cases in a cool, dry place, away from direct sunlight and extreme temperatures.

Figure 8: KM100 stored in its carrying case.
7. Laasigbotitusita
- Ko si Ifihan/Ifihan Arun: Ṣàyẹ̀wò ipele batiri kí o sì pààrọ̀ rẹ̀ tí ó bá pọndandan. Rí i dájú pé àwọn batiri náà wà níbẹ̀ pẹ̀lú polarity tó tọ́.
- Awọn kika ti ko tọ:
- Ensure the rotary switch is set to the correct measurement function and range.
- Rí i dájú pé àwọn ìtọ́wò ìdánwò ti so pọ̀ dáadáa àti pé wọn kò bàjẹ́.
- Fun clamp meter, ensure the jaw is fully closed around a single conductor for current measurement.
- For resistance or continuity, ensure the circuit is de-energized.
- Mita ko dahun: Pa mita naa ki o si tun tan-an. Ti iṣoro naa ba n tẹsiwaju, fi awọn batiri pada.
8. Awọn pato
8.1 KAIWEETS HT206B Clamp Mita
| Wiwọn | Ibiti o | Yiye |
|---|---|---|
| AC Lọwọlọwọ | 6A/60A/600A | ± (2.5%+5) |
| AC Voltage | 6V/60V/600V | ± (1.0%+5) |
| DC Voltage | 600mV/6V/60V/600V | ± (0.5%+5) |
| Atako | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ | ± (1.0%+5) |
| Agbara | 10nF/100nF/1μF/10μF/100μF/1mF/10mF/100mF | ± (4.0%+5) |
| Igbohunsafẹfẹ / ojuse ọmọ | 10Hz to 10MHz | ± (1.0%+3) |
| Iwọn otutu | -4°F si 1832°F (-20°C si 1000°C) | ± (2.5%+5) |
| Awọn iṣiro ifihan | 6000 Awọn iṣiro | |
| Aabo Rating | CAT III 600V, CE, RoHS, IEC 61010-1 | |
| Orisun agbara | 2 x AAA batiri | |
8.2 KAIWEETS KM100 Digital Multimeter
| Wiwọn | Ibiti o | Yiye |
|---|---|---|
| AC Voltage | 20V/200V/600V | ± (1.0%+5) |
| DC Voltage | 200mV/2V/20V/200V/600V | ± (1.0%+5) |
| DC Lọwọlọwọ | 20mA/200mA/10A | ± (1.5%+5) |
| Atako | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ | ± (1.2%+5) |
| Aabo Rating | CAT III 600V, CE, RoHS | |
| Orisun agbara | 2 x Awọn batiri AAA (ti a ti fi sii tẹlẹ) | |
9. Atilẹyin ọja ati Support
KAIWEETS products are designed and manufactured to high-quality standards. Both the HT206B and KM100 are CE and RoHS certified, indicating compliance with European safety, health, and environmental protection requirements.
For specific warranty information or technical support, please refer to the warranty card included with your product or contact KAIWEETS customer service directly through their official channels.