Pedrollo PKM60

Pedrollo PKM60 Peripheral Booster Water Pump Instruction Manual

Model: PKM60

1. Ifihan

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Pedrollo PKM60 Peripheral Booster Water Pump. Please read these instructions carefully before using the pump and retain them for future reference.

The Pedrollo PKM60 pump is designed for use with clean water that does not contain abrasive particles. It is also suitable for liquids that are not chemically aggressive towards the pump's construction materials. Its reliability and ease of use make it ideal for domestic applications, including water distribution in conjunction with small pressure sets and for garden or allotment irrigation.

The pump must be installed in an enclosed environment or at least sheltered from adverse weather conditions to ensure optimal performance and longevity.

2. Alaye Aabo

Nigbagbogbo ṣe akiyesi awọn iṣọra aabo ipilẹ lati dinku eewu ina, mọnamọna, ati ipalara ti ara ẹni.

  • Ensure the power supply matches the pump's specifications (127V, 60Hz).
  • Disconnect power before performing any installation, maintenance, or repair work.
  • Do not operate the pump with flammable or corrosive liquids.
  • Dáàbò bo fifa omi kuro ninu otutu otutu ti o tutu.
  • Rii daju didasilẹ to dara lati ṣe idiwọ mọnamọna.
  • Jeki awọn ọmọde ati awọn oṣiṣẹ laigba aṣẹ kuro ni fifa soke lakoko iṣẹ.

3. Awọn ẹya Ọja

  • Omi Iru: Omi mimọ
  • Nlo: Domestic water supply systems, pressure boosting, irrigation
  • Iwe afọwọkọ: Surface pump
  • Idile: Peripheral pump
  • Iwọn Iṣe: Flow rate up to 11 GPM, Head up to 130 ft.
  • Ibi iwọn otutu olomi: -10 °C si +60 °C

4. Awọn pato

SipesifikesonuẸ̀kúnrẹ́rẹ́
BrandPedrollo
Nọmba awoṣePKM60
Orisun agbaraAC/DC (0.5 HP)
Voltage127V
Igbohunsafẹfẹ60Hz
Oṣuwọn Sisan ti o pọju11 Galonu fun iseju kan (GPM)
O pọju Ori130 ft
O pọju afamora Gbe8 Mita
Ṣiṣẹ Ipa6 igi
Ohun eloIrin Alagbara (awọn paati)
Àwọ̀Buluu
Ọja Mefa12 x 8 x 8 inches
Iwọn Nkan13 iwon
UPC722777873426

5. Eto ati fifi sori

Proper installation is crucial for the pump's performance and longevity. If you are unsure about any steps, consult a qualified professional.

5.1 Ipo

  • Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures.
  • Ensure adequate space around the pump for ventilation and maintenance access.
  • Mount the pump on a stable, level surface to minimize vibration.

5.2 Plumbing Awọn isopọ

  • Use appropriate NPT fittings for inlet and outlet connections.
  • Ensure all connections are watertight to prevent air leaks, which can affect pump performance.
  • Install a foot valve with a strainer on the suction line if drawing water from a well or tank to prevent debris entry and maintain prime.
  • Consider installing isolation valves on both suction and discharge lines for easier maintenance.

5.3 Itanna Asopọ

  • Connect the pump to a dedicated electrical circuit with appropriate overcurrent protection.
  • Rii daju pe ipese agbara voltage and frequency match the pump's requirements (127V, 60Hz).
  • Awọn fifa gbọdọ wa ni ilẹ daradara lati dena awọn eewu itanna.

5.4 Priming fifa soke

Ṣaaju iṣiṣẹ akọkọ, fifa naa gbọdọ wa ni titoju:

  1. Yọ plug priming kuro (nigbagbogbo o wa ni oke fifa soke casing).
  2. Kun fifa casing patapata pẹlu omi mimọ titi yoo fi ṣàn.
  3. Rọpo plug alakoko ni aabo.
  4. Open any discharge valves before starting the pump.
Pedrollo PKM60 Peripheral Booster Water Pump

Nọmba 1: Pedrollo PKM60 Peripheral Booster Water Pump. This image shows the blue pump casing, the motor housing with cooling fins, and the inlet/outlet ports. A small red cap is visible on the pump body, likely indicating a priming or drain point.

6. Awọn ilana Iṣiṣẹ

Once installed and primed, operating the Pedrollo PKM60 pump is straightforward.

  • Bibẹrẹ fifa soke: Ensure all connections are secure and the pump is primed. Turn on the electrical power supply to the pump. The pump should start immediately.
  • Abojuto: Observe the pump during its initial operation for any unusual noises, vibrations, or leaks. Check the pressure gauge (if installed) to ensure proper system pressure.
  • Idaduro fifa soke: Turn off the electrical power supply to the pump.
  • Ṣiṣe gbigbe: Avoid running the pump dry, as this can cause severe damage to the mechanical seal and other components. If the pump runs dry, immediately turn off the power and re-prime it.

7. Itọju

Regular maintenance helps ensure the longevity and efficient operation of your Pedrollo PKM60 pump.

  • Ayẹwo igbagbogbo: Periodically check the pump for any signs of leaks, corrosion, or damage to the casing or electrical connections.
  • Ninu: Keep the pump exterior clean and free from dust and debris to ensure proper motor cooling.
  • Igba otutu: If the pump is exposed to freezing temperatures, drain all water from the pump casing and pipes to prevent damage from ice expansion. Remove the drain plug (if present) and priming plug to facilitate drainage.
  • Igbẹhin ẹrọ: The mechanical seal is a wear item. If persistent leaks occur from the pump shaft area, the seal may need replacement by a qualified technician.

8. Laasigbotitusita

Apá yìí ń sọ̀rọ̀ nípa àwọn ìṣòro tó wọ́pọ̀ tí o lè bá pàdé pẹ̀lú fifa omi rẹ.

IsoroOwun to le FaOjutu
Pump ko bẹrẹNo power supply; tripped circuit breaker; faulty motor.Check power connection and circuit breaker. Consult an electrician if motor is suspected faulty.
Pọ́m̀pù ń ṣiṣẹ́ ṣùgbọ́n omi kò ṣànPump not primed; air leak in suction line; clogged suction line/foot valve; low water level.Re-prime the pump. Check all suction connections for leaks. Clean foot valve/strainer. Ensure adequate water source.
Ìfúnpá omi/ṣíṣàn omi kékeréPartial air leak; partially clogged impeller/pipes; worn impeller; incorrect pipe sizing.Check for air leaks. Inspect and clean impeller/pipes. Consult a technician for impeller wear.
Pump is noisy/vibrates excessivelyAir in pump/suction line; cavitation; loose mounting; worn bearings.Re-prime the pump. Ensure adequate water supply to prevent cavitation. Tighten mounting bolts. Consult a technician for worn bearings.

9. Atilẹyin ọja ati Support

For warranty information, technical support, or spare parts, please contact your authorized Pedrollo dealer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Awọn iwe aṣẹ ti o jọmọ - PKM60

Ṣaajuview Pedrollo PRESFLO MULTI Automatic Control Device - Technical Specifications
Detailed technical specifications, installation guide, and features of the Pedrollo PRESFLO MULTI automatic electronic pressure control device for domestic water supply and pressure boosting.
Ṣaajuview Pedrollo PKm 60® Peripheral Impeller Pump - Technical Specifications and Performance
Detailed information on the Pedrollo PKm 60® peripheral impeller pump, including performance range, application limits, technical specifications, dimensions, and absorption data. Suitable for clean water transfer in domestic applications.
Ṣaajuview Pedrollo STEADYPRES: Variatore Elettronico di Frequenza per Pompe
Manuale completo per il Pedrollo STEADYPRES, un inverter per il controllo di elettropompe. Offre istruzioni dettagliate su installazione, configurazione, funzionamento, gestione allarmi, risoluzione guasti e dati tecnici per ottimizzare la pressione e proteggere la pompa.
Ṣaajuview Pompe Elettrosommergibili Pedrollo: DAVIS, 4-BLOCK, SALI, PRO 100AR - Istruzioni d'Uso
Guida completa alle pompe elettrosommergibili Pedrollo, inclusi i modelli DAVIS, 4-BLOCK, SALI, PRO 100AR, 3SR, 4SR, 4HR, 6SR, 6ST, 6HR, 4PD, 4PS, 6PD, 6PSR. Fornisce dettagli su installazione, uso sicuro, limiti operativi e manutenzione per un efficiente approvvigionamento idrico.
Ṣaajuview Pedrollo TRITUS Submersible Pumps with Grinder: Technical Specifications and Applications
Explore the technical specifications, performance curves, dimensions, and installation guidelines for Pedrollo TRITUS submersible pumps with grinders. Ideal for domestic and civil wastewater management.
Ṣaajuview Pedrollo EP Electronic Protection Device - User Manual & Datasheet
Comprehensive guide to the Pedrollo EP Electronic Protection Device, detailing its features, technical specifications, installation, and operation. Protects pumps from dry running, overcurrent, overvoltage, ati undervoltage. Suitable for domestic use.