ÀRÒPỌ̀ TMT460012

ÀRỌ̀ ÌTỌ́WỌ́ OLÙṢE MÍMẸ́TA TMT460012 NÍPA Ọ̀PỌ̀ ONÍṢẸ́

Àwòṣe: TMT460012

Àmì Ìdámọ̀ràn: ÀRÒPỌ̀

1. Alaye Aabo

Read and understand all safety information and operating instructions before using this multimeter. Failure to follow these instructions may result in electric shock, fire, or damage to the meter.

  • Rí i dájú pé multimeter náà wà ní ipò tó dára àti pé àwọn ìdánwò kò bàjẹ́ kí o tó lò ó.
  • Maṣe lo diẹ sii ju iwọn voltage, which is 600V for this device, between the terminals or between any terminal and ground.
  • Lo iṣọra nigbati o ba n ṣiṣẹ pẹlu voltages loke 30V AC RMS, 42V tente oke, tabi 60V DC. Awọn wọnyi ni voltages duro a mọnamọna ewu.
  • Máa yọ àwọn ìtọ́sọ́nà ìdánwò kúrò nínú àyíká náà kí o tó yí àwọn iṣẹ́ padà.
  • Rọpo batiri naa lẹsẹkẹsẹ nigbati ifihan batiri kekere ba han lati rii daju pe o peye.
  • Do not operate the meter with the case open or if the battery cover is not securely closed.
  • This device is rated for CAT III 600V. Adhere to appropriate safety standards for the measurement category.

2. Ọja Ipariview

The TOTAL Digital Multimeter TMT460012 is a compact, hand-powered device designed for measuring various electrical parameters including DC/AC voltage, DC current, resistance, and continuity. It features a clear digital display and a rotary switch for easy function selection.

TOTAL Digital Multimeter TMT460012 with display, rotary switch, and input jacks.
Aworan yii ṣe afihan iwaju view of the TOTAL Digital Multimeter TMT460012. It features a digital LCD screen at the top, a large central rotary switch for function selection, and three input jacks at the bottom for probe connections. The 'HOLD' button is visible on the right side. The device is blue and grey.

2.1 irinše

  • Ifihan LCD: Ó ń fi àwọn ìkà àti àwọn àmì hàn.
  • Yiyipada Iṣẹ Rotary: Used to select the desired measurement function (e.g., V~, V=, A=, Ω, Continuity).
  • Awọn Jacks ti nwọle:
    • COM (Wọpọ): Fún ìtọ́wò dúdú (òdì).
    • VΩmA: Fún ìdarí ìdánwò pupa (rere) nígbà tí a bá ń wọn ìyókù voltage, resistance, or small currents (mA).
    • 10A: For the red (positive) test lead when measuring high currents (up to 10A). This input is fused.
  • Bọtini Dimu: Didi kika lọwọlọwọ lori ifihan.
  • Awọn itọsọna Idanwo: (Not pictured, but included with the device) Used to connect the multimeter to the circuit under test.

3. Eto

3.1 Fifi sori batiri

The TOTAL TMT460012 multimeter requires two AAA batteries for operation. To install or replace batteries:

  1. Rii daju pe multimeter ti wa ni pipa.
  2. Wa ideri iyẹwu batiri ni ẹhin ẹyọ naa.
  3. Use a screwdriver to remove the screw(s) securing the cover.
  4. Fara yọ ideri kuro.
  5. Fi awọn batiri AAA meji sii, ki o si kiyesi polarity ti o tọ (+ ati -) gẹgẹ bi a ti fihan ninu yara naa.
  6. Rọpo ideri ibi ipamọ batiri naa ki o si fi skru(s) so o mọ.

3.2 Àwọn Ìwádìí Ìdánwò Tó Sopọ̀

To prepare the multimeter for measurements:

  1. Fi dudu igbeyewo asiwaju sinu COM (wọpọ) jack.
  2. Fi asiwaju igbeyewo pupa sinu VΩmA jack for most measurements (voltage, resistance, continuity, small current).
  3. For high current measurements (up to 10A), insert the red test lead into the 10A jaki.

4. Awọn ilana Iṣiṣẹ

Always ensure the correct function is selected and test leads are connected to the appropriate jacks before making any measurements.

4.1 Idiwon DC Voltage (V=)

  1. Ṣeto iyipada iyipo si DC Vol ti o fẹtage range (e.g., 200m, 2, 20, 200, 600V). If the voltage is unknown, start with the highest range and decrease as needed.
  2. So dudu igbeyewo asiwaju si awọn COM jack ati idanwo pupa si asiwaju VΩmA jaki.
  3. Connect the test probes in parallel across the component or circuit to be measured.
  4. Ka voltage iye lori ifihan LCD.

4.2 Iwọn AC Voltage (V~)

  1. Ṣeto iyipada iyipo si AC Vol ti o fẹtagibi tí a lè lo agbára iná (fún àpẹẹrẹ, 200, 600V).
  2. So dudu igbeyewo asiwaju si awọn COM jack ati idanwo pupa si asiwaju VΩmA jaki.
  3. So awọn idanwo idanwo pọ ni afiwe kọja AC voltage orisun.
  4. Ka voltage iye lori ifihan LCD.

4.3 Ìwọ̀n Àìdádúró (Ω)

  1. Rii daju pe iyika naa ti ni agbara ṣaaju idiwọn resistance.
  2. Set the rotary switch to the desired Resistance range (e.g., 200, 2k, 20k, 200k, 2M, 20MΩ).
  3. So dudu igbeyewo asiwaju si awọn COM jack ati idanwo pupa si asiwaju VΩmA jaki.
  4. So àwọn ìwádìí ìdánwò pọ̀ mọ́ ara ẹ̀rọ tí a fẹ́ wọn resistance rẹ̀.
  5. Read the resistance value on the LCD display. An 'OL' reading indicates an open circuit or a resistance higher than the selected range.

4.4 Igbeyewo Ilọsiwaju

  1. Rí i dájú pé ẹ̀rọ náà kò ní agbára púpọ̀.
  2. Set the rotary switch to the continuity function (often indicated by a buzzer icon).
  3. So dudu igbeyewo asiwaju si awọn COM jack ati idanwo pupa si asiwaju VΩmA jaki.
  4. Connect the test probes across the component or wire.
  5. Tí ìtẹ̀síwájú bá wà (ìdènà díẹ̀), mita náà yóò mú ìró ohùn tí a lè gbọ́ jáde.

4.5 Wiwọn Okun DC (A=)

Iṣọra: Never connect the multimeter in parallel for current measurement. Always connect it in series with the load.

  1. Ensure the circuit is de-energized before connecting the meter.
  2. Set the rotary switch to the desired DC Current range (e.g., 200m, 10A).
  3. For currents up to 200mA, connect the black test lead to the COM jack ati idanwo pupa si asiwaju VΩmA jaki.
  4. For currents up to 10A, connect the black test lead to the COM jack ati idanwo pupa si asiwaju 10A jaki.
  5. Open the circuit where the current is to be measured and connect the multimeter in series.
  6. Apply power to the circuit and read the current value on the LCD display.

5. Itọju

5.1 Ninu

Lati nu multimeter, nu ọran naa pẹlu ipolowoamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun tí ó ń yọ́ omi. Rí i dájú pé mita náà gbẹ pátápátá kí o tó lò ó.

5.2 Batiri Rirọpo

Refer to Section 3.1 for detailed instructions on battery replacement. Always use fresh AAA batteries.

5.3 Fiusi Rirọpo

If the 10A current measurement function stops working, the fuse may need replacement. This should only be performed by qualified personnel.

  1. Ensure the multimeter is turned OFF and all test leads are disconnected.
  2. Open the battery compartment cover (refer to Section 3.1).
  3. Locate the fuse(s) inside the compartment.
  4. Carefully remove the old fuse and replace it with a new fuse of the exact same type and rating (e.g., F10A/250V for the 10A range).
  5. Rọpo ideri iyẹwu batiri ki o ni aabo.

6. Laasigbotitusita

  • Kò sí ìfihàn tàbí ìfihàn tí kò dúdú: Ṣayẹwo fifi sori batiri ki o rọpo awọn batiri ti o ba jẹ dandan.
  • 'OL' (Overload) reading: The measured value exceeds the selected range. Select a higher range or check for an open circuit in resistance mode.
  • Awọn kika ti ko tọ: Ensure test leads are properly connected, the correct function is selected, and batteries are not low.
  • No current reading on 10A range: Check and replace the fuse if blown (refer to Section 5.3).

7. Awọn pato

OlupeseLapapọ
Nọmba apakanTMT460012
Iwọn Nkan200 g
Ọja Mefa15 x 8 x 5 cm
Awọn batiriAwọn batiri AAA 2 nilo
Àwọ̀Buluu
AraIwapọ
Agbara Orisun OriṣiAgbara Ọwọ
O pọju Ṣiṣẹ Voltage600 Volts
Awọn iru wiwọnVoltmeter, Ohmmeter, Ammeter

8. Atilẹyin ọja ati Support

For warranty information or technical support, please refer to the product packaging or contact TOTAL customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Awọn iwe aṣẹ ti o jọmọ - TMT460012

Ṣaajuview ÀRỌ̀PỌ̀ TMT460011 Oní-nọ́mbà Oní-nọ́mbà CAT III 600V Ìwé Ìtọ́sọ́nà Ọjà
Ìwé ìtọ́ni olùlò àti àwọn ìlànà ìmọ̀-ẹ̀rọ fún TOTAL TMT460011 Digital Multimeter. Ó ní àwọn ìlànà ààbò, àwọn ìlànà ìṣiṣẹ́, àwọn àlàyé ìwọ̀n, àwọn ìlànà ìṣedéédé, àti àwọn ìlànà ìtọ́jú fún ẹ̀rọ CAT III 600V yìí.
Ṣaajuview Lapapọ Aspirator Blower Ọja Afowoyi - Awọn awoṣe TB2086, UTB2086, ati diẹ sii
Itọsọna ọja osise fun TOTAL Aspirator Blower. Pẹlu awọn ilana aabo alaye, awọn ilana ṣiṣe, awọn alaye imọ-ẹrọ, ati awọn itọnisọna itọju fun awọn awoṣe TB2086, UTB2086, TB2086-4, TB2086-6, TB2086-8, TB2086-9, ati TB2086S. Kọ ẹkọ bii o ṣe le lo ohun elo agbara TOTAL rẹ lailewu ati imunadoko.
Ṣaajuview Àpapọ̀ Ìwé Ìtọ́sọ́nà Olùlò àti Àwọn Ìlànà Ìyípadà Ìtẹ̀sí Àdánidá
Ìwé ìtọ́ni tó péye nípa lílo àti àwọn ìlànà ìmọ̀ ẹ̀rọ fún TOTAL automatic pressure switches, títí kan àwọn àpẹẹrẹ TWPS101, UTWPS101, TWPS1012, TWPS102, àti UTWPS102. Ó ní ààbò, fífi sori ẹrọ, iṣẹ́, ìtọ́jú, àti ìṣòro.
Ṣaajuview Àpapọ̀ Ìwé Ìtọ́sọ́nà Olùlò fún Ìyípadà Ìtẹ̀sí Àdánidá fún TWPS101, UTWPS101, TWPS1012, TWPS102, UTWPS102
Ìwé ìtọ́ni olùlò yìí pèsè ìwífún pípéye fún TOTAL automatic pressure switches, pẹ̀lú àwọn ìlànà ààbò, àwọn ìlànà fífi sori ẹrọ, àwọn ìlànà ìṣiṣẹ́, àwọn ìlànà ìmọ̀-ẹ̀rọ, àti àwọn ìmọ̀ràn lórí ìṣòro fún àwọn àwòṣe TWPS101, UTWPS101, TWPS1012, TWPS102, àti UTWPS102.
Ṣaajuview Lapapọ TMT47504 Цифров Мултицет - Ръководство за Потребителя
Открийте TOTAL TMT47504 – високопроизводителен цифров мултицет, проектиран за яснота и лесна употреба. Този уред е идеален за професионалисти, ентусиасти и домашни потребители надеждни измервания.
Ṣaajuview Lapapọ TMT47504 Цифров Мултицет - Ръководство за Употреба
Пълно ръководство за употреба на TOTAL TMT47504 цифров мултицет, включващо инструкци за безопасност, спецификации и поддръжка.