Unit UT-306C

Ìwé Ìtọ́sọ́nà Olùlò Thermometer Infrared UT-306C Unit

Model: UT-306C | Brand: Unit

1. Ifihan

The Unit UT-306C Infrared Thermometer is a robust and easy-to-use device designed for non-contact surface temperature measurement. This series is suitable for various applications, including the food industry, machine maintenance, metal processing, cold storage, and other industrial fields.

It features a wide temperature range, selectable Celsius/Fahrenheit units, an EBTN display, auto power-off, and low battery indication.

2. Alaye Aabo

Jọ̀wọ́ ka gbogbo ìkìlọ̀ àti ìtọ́ni ààbò kí o tó lo ọjà yìí dáadáa. Àìtẹ̀lé àwọn ìtọ́ni wọ̀nyí lè yọrí sí ìkọlù iná mànàmáná, iná, tàbí ìpalára ńlá.

2.1 Gbogbogbo Aabo Awọn iṣọra

  • Ma ṣe tọka lesa taara si awọn oju tabi awọn oju ti o tan imọlẹ.
  • Do not use the device in environments with explosive gas, vapor, or dust.
  • Jeki ẹrọ naa kuro ni awọn aaye itanna to lagbara.
  • Ma ṣe gbiyanju lati tunto tabi yi ẹrọ naa pada. Tọkasi gbogbo iṣẹ si oṣiṣẹ oṣiṣẹ.
  • Ensure the battery compartment is securely closed before use.

2.2 Aabo lesa

This device uses a Class 2 laser. Avoid direct eye exposure to the laser beam. The laser power is less than 1mW and the wavelength is 630nm-670nm.

3. Product Components and Display

Familiarize yourself with the main parts of your UT-306C Infrared Thermometer.

Unit UT-306C Infrared Thermometer front view

Nọmba 3.1: Iwaju view of the Unit UT-306C Infrared Thermometer, showing the display, trigger, and function buttons.

Unit UT-306C Infrared Thermometer side view

Nọmba 3.2: Apa view of the Unit UT-306C, highlighting the ergonomic grip and laser aperture.

Unit UT-306C Infrared Thermometer display close-up

Nọmba 3.3: Close-up of the EBTN-LCD display on the UT-306C, showing temperature readings and mode indicators.

3.1 Ifihan Ifihan

The EBTN-LCD display provides clear readings and indicators:

  • HI/LO Alarm: Indicates if the measured temperature is above or below set limits.
  • MU: Shows that the current reading is held on the display.
  • °C/°F: Temperature unit indicator.
  • MAX/MIN/AVG/DIF: Indicates the current measurement mode (Maximum, Minimum, Average, or Difference).
  • Batiri Kekere: Icon appears when battery power is low.

4. Eto

4.1 Fifi sori batiri

  1. Wa ibi ipamọ batiri naa lori ọwọ ti iwọn otutu naa.
  2. Ṣii ideri batiri naa.
  3. Fi awọn batiri AAA 1.5V meji sii, ki o rii daju pe polarity ti o tọ (+/-).
  4. Pa ideri batiri naa ni aabo.

4.2 Agbara Tan / Pa

To power on the device, press the trigger. The device will automatically power off after a period of inactivity to conserve battery life.

5. Awọn ilana Iṣiṣẹ

5.1 Ipilẹ wiwọn

  1. Point the thermometer at the target surface.
  2. Press and hold the trigger. The laser pointer will activate (if enabled) to indicate the measurement area.
  3. The temperature reading will appear on the display.
  4. Release the trigger to hold the reading on the display (Data Hold function).

5.2 Unit Selection (°C/°F)

With the device powered on, press the 'SET' button to cycle through settings. Use the up/down arrows to change the temperature unit between Celsius (°C) and Fahrenheit (°F).

5.3 Àtúnṣe Ìtújáde Ìtújáde

Emissivity (ε) is crucial for accurate temperature measurement. The UT-306C allows adjustment from 0.10 to 1.00.

  1. Press the 'MODE' button to enter emissivity adjustment mode.
  2. Use the up/down arrows to increase or decrease the emissivity value.
  3. Press 'MODE' again to confirm and exit.

Refer to a standard emissivity table for common materials to ensure accuracy.

5.4 Measurement Modes (MAX/MIN/AVG/DIF)

Press the 'MODE' button repeatedly to cycle through different measurement modes:

  • O pọju: Displays the maximum temperature measured during a scan.
  • MIN: Displays the minimum temperature measured during a scan.
  • AVG: Displays the average temperature measured during a scan.
  • DIF: Displays the difference between the maximum and minimum temperatures measured during a scan.

5.5 Itaniji iwọn otutu giga / kekere

The device can be set to alarm when temperatures exceed or fall below predefined limits.

  1. Press 'SET' to enter alarm setting mode.
  2. Use the up/down arrows to adjust the high or low alarm threshold.
  3. Press 'SET' again to switch between high and low alarm settings.
  4. Press 'MODE' to exit alarm setting mode.

6. Itọju

6.1 Ninu ẹrọ naa

Láti rí i dájú pé àwọn ìkà tó péye àti láti mú kí ìwọ̀n thermometer rẹ pẹ́ sí i:

  • Clean the lens with a soft, clean cloth or cotton swab moistened with water or medical alcohol.
  • Nu ẹrọ naa casing pẹlu ipolowoamp asọ ati ìwọnba ọṣẹ. Ma ṣe lo abrasive ose tabi epo.
  • Rí i dájú pé ẹ̀rọ náà gbẹ pátápátá kí o tó fi pamọ́ tàbí kí o tó lò ó.

6.2 Batiri Rirọpo

When the low battery indicator appears on the display, replace the batteries as described in the "Battery Installation" section (4.1). Always use two new 1.5V AAA batteries.

6.3 Ibi ipamọ

Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Ẹrọ naa ko ṣiṣẹ.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Ropo awọn batiri, aridaju ti o tọ polarity.
Awọn kika ti ko pe.Incorrect emissivity setting; lens is dirty; distance to spot ratio exceeded.Adjust emissivity; clean the lens; ensure measurement is within 12:1 distance spot ratio.
"HI" or "LO" displayed.Temperature is outside the measurement range (-50°C to 500°C).Ensure the target temperature is within the device's specified range.
Lésà kò hàn.Laser function is disabled.Check settings to ensure laser is enabled.

8. Awọn pato

ParamitaIye
AwoṣeUT306C
Awọn iwe-ẹriCE, UKCA
Iwọn otutu-50℃~500℃ (-58℉~932℉)
Lesa IruCircle
Yiye±2°C tàbí ±2% (èyíkéyìí tó bá pọ̀ jù)
Ipinnu0.1°C
Distance Spot Ratio (D:S)12:1
Akoko Idahun≤250ms
Emissivity0.10~1.00 (adjustable)
Lesa KilasiKilasi 2
Agbara lesa1mW
Lesa wefulenti630nm~670nm
Idahun Spectral8µm~14µm
Ifihan IruEBTN-LCD
Aṣayan kuro° C / ° F
Idaduro dataBẹẹni
Agbara Aifọwọyi PaaBẹẹni
Itọkasi Batiri KekereBẹẹni
Ipo POGBO/MIN/AVG/DIFBẹẹni
Itaniji giga / Low otutuYes (Audible)
Idanwo Drop1m
Agbara2 x 1.5V AAA batiri
Awọ ọjaPupa ati grẹy
Iwọn Ọja161.5g
Iwọn ọja146×78×45mm

9. Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the official Unit webaaye tabi kan si olupin agbegbe rẹ. Tọju iwe-ẹri rira rẹ bi ẹri rira.

Awọn iwe aṣẹ ti o jọmọ - UT-306C

Ṣaajuview Ẹyọ UT202+ AC Clamp Afowoyi olumulo Mita
Ìwé ìtọ́ni olùlò fún UNIT UT202+ AC Clamp Mita, ti o ṣe alaye awọn ẹya ara ẹrọ rẹ, awọn pato, awọn itọnisọna aabo, ati itọju.
Ṣaajuview Unit TYP 01 Awọn ilana Apejọ Aṣọ | Szafa 1D Itọsọna
Àwọn ìlànà ìtòjọpọ̀ tó péye fún aṣọ ìbora Unit TYP 01 (Szafa 1D). Ìtọ́sọ́nà yìí pèsè àkójọ àwọn ẹ̀yà ara, ìdámọ̀ ohun èlò, àti àwọn ìlànà ìrísí ìgbésẹ̀-sí-ìgbésẹ̀ fún títò àwọn aga rẹ láìléwu àti ní ọ̀nà tó tọ́. Ó ní àwọn ìkìlọ̀ ààbò fún gbígbé odi kalẹ̀.
Ṣaajuview Unit UT343E Aso Sisanra won olumulo Afowoyi
Iwe afọwọkọ olumulo fun UNIT UT343E Coating Sisanra Gauge, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, isọdiwọn, ati awọn alaye imọ-ẹrọ fun wiwọn sisanra ti a bo lori irin ati awọn sobusitireti ti kii ṣe irin.
Ṣaajuview Montageanleitung fun Schrank TYP 02
Schritt-für-Schritt-Anleitung zur Montage des Schranks TYP 02 von Unit. Tẹle Teileliste, Iṣẹ ati Sicherheitshinweise fun a fi sori ẹrọ ati fifi sori ẹrọ.
Ṣaajuview Unit:inch Dimensions and Specifications
This document provides dimensional information in inches for various units and components, detailing measurements such as length, width, and height for different parts.
Ṣaajuview Technical Dimensions and Specifications for Unit 54056000
Detailed technical drawing and dimensions for unit model 54056000, providing measurements for height, width, and depth in a clear, accessible format.