1. Ifihan

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Einhell GE-DP 900 Cut Dirty Water Pump. Please read these instructions carefully before using the pump for the first time. Keep this manual in a safe place for future reference.

The Einhell GE-DP 900 is a powerful dirty water pump designed for pumping water with a high percentage of foreign bodies. It is suitable for applications such as draining basements, excavations, ponds, rain barrels, and wells. The integrated cutting mechanism allows for shredding of solid particles, enhancing its utility in highly contaminated water.

2. Awọn ilana aabo

IKILO: Always disconnect the pump from the power supply before performing any maintenance, cleaning, or adjustments. Failure to do so can result in serious injury or death.

  • Rii daju pe ipese agbara voltage matches the rating on the pump's nameplate.
  • Do not operate the pump if the power cable or plug is damaged.
  • Never lift or carry the pump by its power cable.
  • Pa awọn ọmọde ati awọn eniyan ti ko ni aṣẹ mọ kuro ni fifa ẹrọ ti n ṣiṣẹ.
  • Do not use the pump for flammable, explosive, or corrosive liquids.
  • Ensure adequate ventilation if operating in confined spaces.
  • Always use a residual current device (RCD) with a tripping current not exceeding 30 mA.
  • Dabobo fifa soke lati Frost.

3. Ọja Ipariview

The Einhell GE-DP 900 is constructed with a robust cast aluminum and cast iron housing for durability. Key components include the motor, pump housing, float switch, and hose connection.

Einhell GE-DP 900 Cut Dirty Water Pump

Nọmba 3.1: Pariview of the Einhell GE-DP 900 Cut Dirty Water Pump. This image shows the complete pump unit, highlighting its red and black casing, integrated float switch, and hose connection port.

Close-up of Einhell GE-DP 900 pump with float switch

Nọmba 3.2: Sun mo tipetipe view of the pump's main body and the float switch. The float switch is crucial for automatic operation, turning the pump on and off based on water levels.

Hose connection on Einhell GE-DP 900 pump

Nọmba 3.3: Detail of the 2-inch hose connection. This connection allows for the attachment of large diameter hoses, facilitating efficient water discharge.

Cutting mechanism at the base of Einhell GE-DP 900 pump

Nọmba 3.4: View of the integrated cutting mechanism located at the base of the pump. This mechanism is designed to shred solid particles up to 35 mm in diameter, preventing blockages.

4. Eto

  1. Ṣii silẹ: Carefully remove the pump and all accessories from the packaging. Inspect for any damage during transit.
  2. Asopọ okun: Attach a suitable discharge hose to the 2-inch connector on the pump. Ensure the connection is secure to prevent leaks during operation.
  3. Ipo: Place the pump on a stable, level surface in the water to be pumped. Ensure the pump is fully submerged if operating in automatic mode with the float switch. The maximum immersion depth is 7 meters.
  4. Àtúnṣe Ìyípadà Lílefó: The float switch controls the automatic on/off function. Adjust its position to set the desired minimum and maximum water levels for operation. The pump will start when the water level rises and lift the float switch, and stop when the water level drops and the float switch falls.
  5. Asopọ agbara: Connect the power cable to a grounded electrical outlet (230V AC) protected by a residual current device (RCD).

5. Awọn ilana Iṣiṣẹ

  1. Isẹ aladaaṣe:
    • Ensure the float switch is freely movable and adjusted to the desired water levels.
    • Plug the pump into the power supply. The pump will start automatically when the water level reaches the upper activation point of the float switch.
    • The pump will stop automatically when the water level drops to the lower deactivation point of the float switch.
  2. Isẹ afọwọṣe:

    For continuous operation, some models allow the float switch to be secured in an upward position. Refer to the specific markings or instructions on your pump for manual mode. In manual mode, the pump will run continuously until unplugged or the water level drops below the pump's intake.

  3. Abojuto: During operation, periodically check the pump for unusual noises or vibrations. Ensure the discharge hose is not kinked or blocked.
  4. Tiipa: To stop the pump, disconnect it from the power supply. If operating in automatic mode, it will stop when the water level drops.
Man operating Einhell GE-DP 900 pump in a muddy pond

Nọmba 5.1: An individual demonstrating the use of the Einhell GE-DP 900 pump in a muddy water environment. This illustrates a typical application for dirty water removal.

6. Itọju

Regular maintenance ensures the longevity and optimal performance of your pump. Always disconnect the pump from the power supply before any maintenance.

  • Ninu: After each use, especially with dirty water, rinse the pump thoroughly with clean water. Remove any debris or foreign objects from the intake screen and cutting mechanism.
  • Ayewo: Periodically inspect the power cable, plug, and float switch for any signs of damage or wear. Check the hose connections for tightness.
  • Idaabobo otutu: If the pump is stored in an area where temperatures may drop below freezing, ensure all water is drained from the pump to prevent damage.
  • Ibi ipamọ: Store the pump in a dry, frost-free location when not in use.

7. Laasigbotitusita

Abala yii n ṣalaye awọn ọran ti o wọpọ ti o le ba pade. Fun awọn iṣoro ti ko ṣe akojọ si ibi, kan si atilẹyin alabara.

IsoroOwun to le FaOjutu
Pump ko bẹrẹ.No power supply; float switch not activated; motor overload protection triggered.Check power connection and circuit breaker; adjust float switch position; allow motor to cool down.
Pọ́ọ̀pù náà ń ṣiṣẹ́ ṣùgbọ́n omi kò jáde.Intake blocked; discharge hose kinked or blocked; airlock in pump.Clean intake screen; clear discharge hose; submerge pump fully and shake gently to release air.
Reduced pumping capacity.Partial blockage; worn impeller (unlikely for new pump).Clean intake and cutting mechanism; ensure hose is clear.
Pump stops unexpectedly.Float switch deactivated; motor overload protection triggered.Check water level and float switch position; allow motor to cool.

8. Imọ ni pato

Ẹya ara ẹrọSipesifikesonu
BrandEinhell
Nọmba awoṣe4181550
Orisun agbaraAC
Voltage230 Volts
Power (Motor)900 Wattis
Oṣuwọn Sisan ti o pọju16,000 liters fun wakati kan
Iwọn Gbígbé Gbígbé11.5 meters (393.7 Inches)
Maximum Immersion Depth7 mita
O pọju. Patiku Iwon35 mm
Awọn iwọn Ọja (L x W x H)10.83" x 8.78" x 16.54"
Iwọn Nkankilo 12.8 (28.2 poun)
Ohun eloAluminum, Cast Iron
Pataki Awọn ẹya ara ẹrọIntegrated Cutting Mechanism, Adjustable Float Switch

9. Atilẹyin ọja ati Support

Einhell products are manufactured with quality and durability in mind. For warranty information, please refer to the warranty card included with your purchase or visit the official Einhell webojula.

For technical support, spare parts, or service inquiries, please contact Einhell customer service. Contact details can typically be found on the Einhell webaaye tabi ninu iwe ọja rẹ.

Àkókò Wíwà Àwọn Ohun Èlò Pàtàkì EU: Ọdún 1 (gẹ́gẹ́ bí àwọn ìlànà ọjà).

Awọn iwe aṣẹ ti o jọmọ - GE-DP 900

Ṣaajuview Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe / Flutset Bedienungsanleitung
Diese Anleitung beschreibt die Bedienung und Wartung der Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe und des Flutsets. Sie enthält wichtige Sicherheitshinweise, technische Daten und Anleitungen zur Fehlerbehebung für den effizienten Einsatz der Pumpe.
Ṣaajuview Einhell GC-DP 3325 Schmutzwasserpumpe Bedienungsanleitung
Originalbetriebsanleitung für kú Einhell GC-DP 3325 Schmutzwasserpumpe. Ṣe igbasilẹ Sicherheitshinweise, Awọn fifi sori ẹrọ, Bedienung ati Wartung.
Ṣaajuview Einhell GE-CF 18/2200 Li Ailokun Fan ọna Afowoyi
Iwari Einhell GE-CF 18/2200 Li Ailokun àìpẹ. Iwe afọwọkọ iṣiṣẹ yii ṣe alaye awọn ẹya ara ẹrọ fun fentilesonu ile, pẹlu agbara Ailokun, awọn iyara adijositabulu, ati gbigbe. Kọ ẹkọ nipa iṣẹ ailewu, itọju, ati alaye atilẹyin ọja.
Ṣaajuview Einhell TC-RH 900 Bohrhammer Bedienungsanleitung
Dieses Dokument enthält eine umfassende Bedienungsanleitung, Sicherheitshinweise, technische Daten und Wartungsinformationen fun Einhell TC-RH 900 Bohrhammer. Unverzichtbar für die sichere und effektive Nutzung des Elektrowerkzeugs.
Ṣaajuview Einhell GE-SP 18 Li Akku-Klarwasserpumpe Bedienungsanleitung
Die offizielle Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Enthält detaillierte Informationen zu Sicherheit, Installation, Betrieb, Wartung und Fehlerbehebung für dieses leistungsstarke Gartengerät.
Ṣaajuview Einhell TC-RH 900 Bohrhammer Bedienungsanleitung
Umfassende Bedienungsanleitung und Sicherheitshinweise fun Einhell TC-RH 900 Bohrhammer. Enthält technische Daten, Bedienungsanleitungen, Wartungs- und Garantieinformationen.