Teleflex 63962

Teleflex Boat Fuel Gauge 63962 User Manual

Model: 63962 | Brand: Teleflex | Series: Lido Black Series 2 Inch

Ọrọ Iṣaaju

This manual provides essential information for the installation, operation, and maintenance of your Teleflex Boat Fuel Gauge, Model 63962. This gauge is designed for marine applications and features a 2-inch diameter, Lido Black Series styling, and operates within a 33-240 Ohm range. Please read these instructions carefully before proceeding with installation or use.

Alaye Aabo

Always observe the following safety precautions to prevent personal injury or damage to the product or vessel:

Package Awọn akoonu

The Teleflex Boat Fuel Gauge 63962 package typically includes:

Akiyesi: Mounting hardware, wiring, and a detailed installation manual are generally not included with this product and must be sourced separately. This document serves as a general guide.

Fifi sori Itọsọna

This section outlines the general steps for installing the fuel gauge. Professional installation is recommended.

1. Mounting the Gauge

  1. Select a suitable location on your dashboard or instrument panel. The gauge requires a 2-inch (approximately 52mm) diameter cutout.
  2. Carefully cut the mounting hole using appropriate tools. Ensure the hole is clean and free of debris.
  3. Insert the gauge into the cutout from the front.
  4. Secure the gauge from the rear using the provided (or separately purchased) mounting bracket and nuts. Do not overtighten.
Iwaju view of the Teleflex Boat Fuel Gauge 63962

Aworan 1: Iwaju view of the Teleflex Boat Fuel Gauge 63962. This image displays the gauge's face with markings for 'E' (Empty), '1/2', and 'F' (Full), along with the 'FUEL' label and a red indicator needle. The gauge has a chrome bezel and a black dial with white markings.

2. Awọn itọnisọna Wiring

The gauge features three threaded bolt connections on the rear for electrical wiring. Refer to your vessel's wiring diagram for specific connections.

  1. Isopọ ilẹ: Connect one of the threaded bolts to a reliable ground source on your vessel.
  2. Ignition/Power Connection: Connect another threaded bolt to a switched 12V DC power source (e.g., ignition circuit).
  3. Sender Connection: Connect the remaining threaded bolt to the output wire from your fuel tank sender unit. This gauge is designed for 33-240 Ohm senders.
  4. Ensure all connections are tight and insulated to prevent corrosion and short circuits.
Ẹyìn view of the Teleflex Boat Fuel Gauge 63962 showing electrical connections

Aworan 2: Ẹyìn view of the Teleflex Boat Fuel Gauge 63962. This image shows the back of the gauge, highlighting the three threaded bolt terminals for electrical connections (power, ground, and sender input). The light blue casing and metal mounting brackets are also visible.

Product label for Teleflex 63962 fuel gauge

Aworan 3: Product label for Teleflex 63962 fuel gauge. This label confirms the part number P63962 and indicates the item description as "FUEL E-F240 OHM", confirming the 33-240 Ohm range for the fuel sender compatibility.

Awọn ilana Iṣiṣẹ

Once properly installed and wired, the Teleflex Boat Fuel Gauge operates automatically when the vessel's ignition is turned on.

Itoju

Regular maintenance helps ensure the longevity and accuracy of your fuel gauge.

Laasigbotitusita

If you experience issues with your fuel gauge, consider the following troubleshooting steps:

Awọn pato

Part ManufacturerTeleflex
Nọmba apakan63962
jaraLido Black Series
Àwọ̀Silver Bezel, Black Dial, White Markings
Ìwò Mefa2 1/4" Diameter x 2 5/8" Depth (approx.)
Awọn iwọn gige gige2" Diameter (approx.)
Asopọmọra Iru3 Threaded Bolts
Ohm Range33-240 Ohm (Standard)
Ohun eloIrin
Iwọn NkanIsunmọ 5 iwon

Atilẹyin ọja ati Support

Specific warranty information for the Teleflex Boat Fuel Gauge 63962 should be obtained from your retailer or directly from the manufacturer, Teleflex. Please retain your proof of purchase for any warranty claims.

For technical support or further inquiries, please contact Teleflex customer service or visit their official webojula.

Awọn iwe aṣẹ ti o jọmọ - 63962

Ṣaajuview Awọn ilana ati awọn alaye pato ti ẹrọ adaṣe Hudson RCI Voldyne 2500 Volumetric
Comprehensive user instructions and technical details for the Hudson RCI Voldyne 2500 Volumetric Exerciser, a respiratory therapy device for adult and pediatric patients. Includes guidance on use, cleaning, patient progress tracking, and predictive inspiratory capacity nomograms.
Ṣaajuview Arrow VPS Rhythm DLX Device - Fun rira | Teleflex Vascular Access Product Catalog
Awọn alaye ọja fun Arrow VPS Rhythm DLX Device - Cart, SKU DLX-200-CART, lati Teleflex Vascular Access Product Catalog. Pẹlu iye tita ati alaye lilo pataki.
Ṣaajuview Ẹ̀rọ ìtọ́jú katẹ́ẹ̀tì oní-ẹ̀rọ tẹliflex ARROW One-Lumen CVC CV-04706 - Ìwọ̀sí Iṣan
Teleflex ARROW CV-04706 is a One-Lumen Central Venous Catheter (CVC) set, featuring a 14 GA x 6" (16 CM) catheter. This product catalog details components, highlights, considerations, and important safety information for this medical device.
Ṣaajuview Ìtọ́sọ́nà Ọkọ̀ Àyà: Àwọn Ohun Èlò, Ìṣètò, Ìṣàyẹ̀wò Àìsàn, àti Ìtọ́jú Nọ́ọ̀sì
Ìtọ́sọ́nà pípéye sí ìfisí àyà, ètò ìṣàn omi Pleur-Evac, àwọn àkíyèsí ìtọ́jú ọmọ, ìṣòro, àti ẹ̀kọ́ fún aláìsàn. Ó ní àwọn ẹ̀yà ara, ìṣètò, ìṣàyẹ̀wò ìṣàn omi afẹ́fẹ́, ìtújáde omi, àti àwọn ìṣòro tó wọ́pọ̀.
Ṣaajuview Arrow EZ-IO Eto Wiwọle Vascular Intraosseous: Awọn ilana fun Lilo & Alaye Ọja
Awọn itọnisọna okeerẹ fun lilo, awọn itọkasi, awọn ilodisi, alaye ailewu, ati awọn alaye imọ-ẹrọ fun Teleflex Arrow EZ-IO Intraosseous Vascular Access System ati Awakọ Agbara Lo Nikan. Pẹlu itoni lori fifi sii, yiyọ kuro, aabo MRI, ati ibaramu itanna.
Ṣaajuview AsthmaMD Peak Flow Meter by Teleflex - Improve Asthma Management
Learn about the AsthmaMD Peak Flow Meter by Teleflex, a portable device for patients to measure peak expiratory flow, track symptoms, and manage asthma effectively. Features include accuracy, ease of use, and mobile app compatibility.