This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity K2 CP 10 kW wood stove. Please read these instructions carefully before using the appliance and retain them for future reference. Proper adherence to these guidelines will ensure optimal performance and longevity of your stove.

Prity K2 CP Wood Stove with fire burning in the combustion chamber

Aworan 1: Iwaju view of the Prity K2 CP wood stove with a visible fire through the ceramic glass door.

1.1 Ọja Loriview

The Prity K2 CP is a 10 kW wood-burning stove designed for heating residential spaces. It features a robust construction with a reinforced combustion chamber lined with refractory bricks for heat accumulation and improved combustion temperature. The stove is equipped with heat-resistant ceramic glass, a cast iron grate, and two manual dampers for precise air and flame intensity control. An integrated compartment is provided for storing and drying wood.

1.2 Abo Alaye

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

  • Always ensure adequate ventilation in the room where the stove is installed.
  • Maintain required clearances to combustible materials as specified in local building codes and this manual.
  • Only use recommended fuels (wood, coal). Do not burn plastics, treated wood, or other unsuitable materials.
  • Regularly inspect and clean the flue system to prevent creosote buildup and chimney fires.
  • Keep children and pets away from the hot surfaces of the stove.
  • Install smoke and carbon monoxide detectors in your home.

2. Eto ati fifi sori

Installation must be performed by a qualified professional and comply with all local and national building and fire safety regulations.

2.1 Unpacking ati ayewo

Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately. Ensure all components listed in the packing list are present.

2.2 Ipo ati Clearances

Choose a suitable location for the stove, ensuring it is on a non-combustible floor or hearth. Maintain the minimum clearances to combustible walls and materials as specified by local regulations and the manufacturer. The flue pipe connection is at the top of the stove.

Prity K2 CP Wood Stove with Ecodesign 2022 and Blm SchV2 labels

Image 2: Prity K2 CP wood stove displaying Ecodesign 2022 and Blm SchV2 certifications, indicating compliance with environmental standards.

2.3 Flue System Connection

Connect the stove to a suitable chimney or flue system with a diameter of 130 mm. Ensure all connections are sealed properly to prevent smoke leakage. The chimney must be in good condition, free of obstructions, and capable of providing adequate draft.

2.4 Initial Firing (Curing)

Before regular use, the stove must be cured to allow the paint and internal components to settle. This process involves several small, low-temperature fires. During curing, some smoke and odor may be emitted; ensure the area is well-ventilated. Avoid high temperatures during the first few fires.

3. Awọn ilana Iṣiṣẹ

Understanding how to properly operate your Prity K2 CP stove is crucial for safety, efficiency, and comfort.

3.1 Irú epo

The Prity K2 CP stove is designed to burn wood and coal. For optimal performance and to minimize creosote buildup, use dry, seasoned hardwood. Wood with a moisture content of 20% or less is recommended. Avoid burning:

  • Tutu tabi igi ti ko to akoko
  • Garbage, plastics, or chemical waste
  • Itọju tabi ya igi
  • Awọn olomi flammable

3.2 Itanna adiro

  1. Open both the front air supply damper and the smoke damper fully.
  2. Place crumpled paper or natural firelighters on the cast iron grate.
  3. Add a small amount of kindling (small, dry pieces of wood) on top of the firelighters.
  4. Light the firelighters.
  5. Once the kindling is burning well, gradually add larger pieces of wood.
  6. Close the combustion chamber door once the fire is established.

3.3 Air Iṣakoso

The stove is equipped with two manual dampawon:

  • Front Air Dampnitori: Located at the front, this controls the primary air supply to the combustion chamber. Open it for ignition and when adding new fuel. Close it partially to reduce the burn rate and conserve fuel.
  • Ẹfin Dampnitori: This regulates the intensity of the flame and the draft through the flue. Adjust it to achieve a steady, efficient burn.

Adjusting these dampers allows you to control the heat output and efficiency. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or wet fuel.

3.4 epo epo

When adding more fuel, open the front air damper and smoke damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Carefully place new logs onto the existing embers and close the door. Adjust the dampers once the new fuel has ignited.

4. Itọju

Regular maintenance is essential for the safe and efficient operation of your Prity K2 CP stove.

4.1 Ash Yiyọ

Remove ash regularly from the ash pan, typically when it is about two-thirds full. Do not allow ash to build up and touch the bottom of the grate, as this can restrict airflow and damage the grate. Always use a metal container with a tight-fitting lid for ash disposal, as embers can remain hot for days.

4.2 Glass Cleaning

The ceramic glass in the combustion chamber door can become dirty with soot. Clean it when the stove is cold using a specialized glass cleaner for wood stoves or a damp cloth dipped in ash. Avoid abrasive cleaners or tools that could scratch the glass.

4.3 Flue and Chimney Cleaning

The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage and fuel type. Creosote buildup is a fire hazard. This task should be performed by a certified chimney sweep.

4.4 Gbogbogbo ayewo

Periodically check the door seals for wear and tear. Replace them if they are damaged to ensure an airtight seal. Inspect the refractory bricks for cracks or damage; while minor cracks are normal, severely damaged bricks should be replaced.

5. Laasigbotitusita

This section addresses common issues you might encounter with your wood stove.

IsoroOwun to le FaOjutu
Smoke entering the roomInsufficient draft, blocked chimney, opening door too quickly, wet fuel.Check chimney for blockages, ensure dampers are open, pre-heat flue, use dry fuel, open door slowly.
Ijade ooru ti ko daraWet fuel, insufficient air, stove too small for space, excessive ash.Use dry fuel, adjust air dampers, remove ash, ensure stove size is appropriate.
Rapid burning of fuelToo much air supply, faulty door seal.Afẹfẹ sunmọ dampers partially, check and replace door seals if necessary.
Gilasi dudu ni kiakiaWet fuel, low burning temperature, insufficient air wash.Use dry fuel, ensure adequate air supply, clean glass regularly.

6. Awọn pato

Technical data for the Prity K2 CP 10 kW Wood Stove.

Ẹya ara ẹrọIye
BrandPrity (BALKAN ENERGY)
AwoṣeK2 CP
Awọn iwọn Ọja (H x W x D)810 x 500 x 510 mm
Combustion Chamber Dimensions (H x W x D)400 x 365 x 410 mm
Alapapo Agbara10 kW
Alapapo dada AreaIsunmọ. 57 m²
Iṣẹ ṣiṣe75-80%
Flue Pipe opin130 mm
Ipo flueOke
Epo IruWood, Coal
Ohun eloStainless Steel (Body), Cast Iron (Grate, Top Plate), Ceramic Glass
Àwọ̀Dudu Awọ
Iwọn90 kg
Agbara KilasiA
IjẹrisiCE, EN Standard
Nọmba Iforukọ EPREL1271282

7. Atilẹyin ọja ati Support

For warranty information, technical support, or spare parts, please contact the manufacturer or your retailer.

Please have your model number (K2 CP) and purchase date available when contacting support.

Awọn iwe aṣẹ ti o jọmọ - K2 CP

Ṣaajuview Awọn igbomikana Prity: Apejuwe Imọ-ẹrọ, Fifi sori ẹrọ, ati Itọsọna Iṣiṣẹ
Itọsọna okeerẹ fun awọn igbomikana ibugbe Prity, ibora awọn alaye imọ-ẹrọ, awọn ilana fifi sori ẹrọ, awọn ilana ṣiṣe, itọju, ati laasigbotitusita fun epo to lagbara ati awọn awoṣe pellet.
Ṣaajuview Truma Combi (E) Operating Instructions and Technical Guide
Comprehensive operating instructions and technical specifications for the Truma Combi (E) caravan and motorhome heater. Covers installation, operation, safety, maintenance, troubleshooting, and warranty information.
Ṣaajuview Lochinvar Copper-Fin II Olona Pool Pool CP-SPEC-10 Awọn pato Imọ-ẹrọ
Awọn alaye imọ-ẹrọ alaye fun Lochinvar Copper-Fin II igbona adagun adagun-owo, awoṣe CP-SPEC-10, awọn ẹya ti o bo, ikole, awọn iṣakoso, ati awọn iwe-ẹri fun adagun-odo ati awọn ohun elo spa.
Ṣaajuview Truma CP pẹlu Awọn ilana Iṣiṣẹ ati Itọsọna Laasigbotitusita
Awọn ilana iṣiṣẹ okeerẹ ati itọsọna laasigbotitusita fun Truma CP pẹlu nronu iṣakoso, fifi sori fifi sori ẹrọ, iṣẹ ṣiṣe, awọn iṣẹ ṣiṣe, ati idanimọ aṣiṣe fun Combi gaasi ati awọn igbona diesel, ati awọn eto imuletutu.
Ṣaajuview Truma AquaGo Awọn ilana Itọkasi Decalcification ati Itọsọna Itọju
Detailed instructions for decalcifying your Truma AquaGo RV water heater. This guide covers procedures for both Analog Dial and CP plus controller models, including troubleshooting steps for common issues like being stuck in clean mode.