Kair KMF100T

Kair MultiFan 100mm In-Line Extractor Fan with Timer

Awoṣe: KMF100T

1. Ifihan

The Kair MultiFan KMF100T is a versatile in-line extractor fan designed for effective ventilation in various domestic and commercial settings. This unit is suitable for use in bathrooms, kitchens, offices, and other areas requiring air extraction. It features a 100mm duct compatibility, a 2-speed operation, and an adjustable timer function, providing powerful airflow while maintaining a low noise level.

Iwaju view of the Kair MultiFan 100mm In-Line Extractor Fan with Timer.

Figure 1.1: The Kair MultiFan KMF100T In-Line Extractor Fan.

Image showing Kair MultiFan improving ventilation in a bathroom, kitchen, and commercial space.

Figure 1.2: The Kair MultiFan is designed to improve ventilation and reduce humidity in various environments such as bathrooms, kitchens, and commercial spaces.

2. Alaye Aabo

Please read all safety instructions carefully before installing or operating the Kair MultiFan KMF100T. Failure to follow these instructions may result in electric shock, fire, or personal injury.

  • Always disconnect the power supply before performing any installation, maintenance, or cleaning.
  • Fifi sori ẹrọ gbọdọ ṣee ṣe nipasẹ oṣiṣẹ ina mọnamọna ti o pe ni ibamu pẹlu awọn ilana wiwọ agbegbe.
  • Ensure the fan is properly grounded to prevent electric shock.
  • Do not operate the fan if the power cord or any part of the unit is damaged.
  • Jeki awọn ọwọ ati awọn nkan ajeji kuro lati awọn abẹfẹfẹ afẹfẹ lakoko iṣẹ.
  • Ohun elo yii kii ṣe ipinnu fun lilo nipasẹ awọn eniyan (pẹlu awọn ọmọde) pẹlu idinku ti ara, imọlara tabi awọn agbara ọpọlọ, tabi aini iriri ati imọ, ayafi ti wọn ba ti fun wọn ni abojuto tabi itọnisọna nipa lilo ohun elo nipasẹ eniyan ti o ni iduro fun aabo wọn.
  • Do not use this fan in areas where flammable or explosive gases are present.

3. Package Awọn akoonu

Daju pe gbogbo awọn paati wa ati pe ko bajẹ lori ṣiṣi package naa:

  • Kair MultiFan KMF100T In-Line Extractor Fan Unit
  • Mounting brackets and screws (may vary by package)
  • Ilana Afowoyi (iwe yii)

4. Awọn pato

Technical drawing of the Kair MultiFan KMF100T with dimensions labeled as ØD, B, H, L, and weight.

Figure 4.1: Dimensional drawing of the Kair MultiFan KMF100T, showing measurements in millimeters and weight in kilograms.

Table 4.1: Kair MultiFan KMF100T Technical Specifications
Ẹya ara ẹrọSipesifikesonu
AwoṣeKMF100T
BrandKair
Ipin Opin100 mm (Spigot ØD: 96mm)
Awọn iwọn (L x W x H)24.6 x 16.7 x 19 cm (L: 246mm, B: 167mm, H: 190mm)
Iwọn1.35 kg
Agbara agbara21 Watts (Min) - 33 Watts (Max)
Voltage230 Volts
Ohun eloṢiṣu
Nọmba ti Awọn iyara2
Ariwo IpeleFrom 27 Decibels
Sisan afẹfẹ (Max)187 m³/h (52 l/s)
Pataki Awọn ẹya ara ẹrọAdjustable Speed Control, Timer Function
IP RatingIPX4
Table showing technical data for Kair MultiFan models including speed, airflow, power, and noise level for 100mm, 125mm, and 150mm sizes.

Figure 4.2: Detailed technical data for Kair MultiFan series, including the 100mm model (KMF100T).

5. fifi sori

The Kair MultiFan KMF100T is designed for in-line installation within ducting systems. It can be mounted in various positions, including ceiling voids, wall cavities, or loft spaces. Ensure the chosen location allows for proper airflow and access for maintenance.

5.1 Iṣagbesori Fan

  1. Yan Ibi: Choose a suitable, stable location for mounting the fan. Consider accessibility for wiring and future maintenance.
  2. Iṣagbesori to ni aabo: Use the provided mounting brackets and screws to securely attach the fan unit to a solid surface. Ensure the fan is firmly fixed to minimize vibration and noise.
  3. Asopọmọra Tita: Connect 100mm diameter ducting to both inlet and outlet spigots of the fan. Use appropriate clamps or tape to ensure airtight connections. The maximum recommended duct length is 5 meters without bends for optimal performance.
Diagram showing installation examples of the Kair MultiFan in a bathroom and an office setting with ducting.

Olusin 5.1: Examples of Kair MultiFan installation in a bathroom and office environment. Ducting and accessories are sold separately.

5.2 Itanna onirin

IKILO: Electrical wiring must be performed by a qualified electrician. Ensure the main power supply is disconnected before commencing any wiring work.

  • The KMF100T requires a 230V AC power supply.
  • Connect the live, neutral, and earth wires to the corresponding terminals within the fan's wiring compartment.
  • For the timer function, a switched live connection is typically required from a light switch or separate control.
  • Refer to the wiring diagram provided inside the fan's terminal cover for specific connections.
  • Rii daju pe gbogbo awọn asopọ wa ni aabo ati idabobo daradara.
Kair MultiFan KMF100T connected to a 90-degree duct bend and a ceiling grille, showing a typical installation setup.

Olusin 5.2: Example of the Kair MultiFan connected to ducting and a ceiling grille.

Kair MultiFan KMF100T with ducting and an external wall grille, illustrating an exhaust setup.

Olusin 5.3: Example of the Kair MultiFan connected to ducting and an external wall grille.

Kair MultiFan KMF100T with ducting and a different style of external wall grille, showing another exhaust option.

olusin 5.4: Miiran example of the Kair MultiFan connected to ducting and an external wall grille.

6. Isẹ

The Kair MultiFan KMF100T features two operating speeds and an adjustable timer function.

  • Yiyan Iyara: The fan can operate at two different speeds (Min and Max) to suit varying ventilation requirements. The speed setting is typically configured during installation via internal wiring or a switch.
  • Iṣẹ Aago: The integrated timer allows the fan to continue running for a set period after the main power switch (e.g., light switch) is turned off. The timer duration is adjustable. To set the timer, access the internal timer adjustment screw (usually located near the wiring terminals) and rotate it to increase or decrease the run-on time. A small screwdriver is typically required for this adjustment. Test the setting to achieve the desired run-on duration.

7. Itọju

Regular maintenance ensures optimal performance and longevity of your Kair MultiFan KMF100T.

  • Ge asopọ agbara: Always disconnect the fan from the main power supply before performing any cleaning or maintenance.
  • Ode Ninu: Mu ese ita ti afẹfẹ afẹfẹ pẹlu asọ, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the plastic housing.
  • Ayewo inu: Periodically inspect the fan blades and internal components for dust, lint, or debris accumulation. If accessible and safe to do so, carefully remove any obstructions.
  • Ducting Check: Ensure that the connected ducting remains clear and free of blockages. Blockages can reduce airflow and increase noise.

8. Laasigbotitusita

If you encounter issues with your Kair MultiFan KMF100T, refer to the following troubleshooting guide:

IsoroOwun to le FaOjutu
Fan ko ni tan-an.Ko si ipese agbara.
Ti firanṣẹ ti ko tọ.
Yipada aṣiṣe.
Check the circuit breaker and ensure power is supplied to the fan. Verify wiring connections (consult a qualified electrician). Test the control switch.
Afẹ́fẹ́ náà ń pariwo púpọ̀.Iṣagbesori alaimuṣinṣin.
Obstruction in fan blades or ducting.
Damaged fan motor/bearings.
Ensure the fan is securely mounted. Disconnect power and check for debris in the fan or ducting. If noise persists, contact support.
Poor or no airflow.Ducting blockage.
Incorrect ducting installation.
Fan running at low speed.
Check ducting for obstructions. Ensure ducting is properly sealed and not kinked. Verify the fan speed setting.
Iṣẹ aago ko ṣiṣẹ ni deede.Eto aago ti ko tọ.
Wiring issue for switched live.
Adjust the timer setting screw. Ensure the switched live wire is correctly connected (consult a qualified electrician).

If the problem persists after attempting these solutions, please contact Kair customer support.

9. Atilẹyin ọja ati Support

The Kair MultiFan KMF100T comes with a 2-odun atilẹyin ọja from the date of purchase, covering manufacturing defects and material faults under normal use.

For warranty claims, technical assistance, or any product-related inquiries, please contact Kair customer service. Keep your proof of purchase for warranty validation.

Ibi iwifunni: Please refer to the Kair official website or your purchase documentation for the most up-to-date customer support contact details.

Awọn iwe aṣẹ ti o jọmọ - KMF100T

Ṣaajuview Kair CRE100HTP Smart Fan Installation and Maintenance Guide
This guide provides detailed instructions for the installation and maintenance of the Kair CRE100HTP Smart Fan. It covers safety precautions, unit dimensions, installation procedures for wall and window mounting, wiring diagrams, operational settings, and disposal information.