1. Ifihan
The TOTAL TMT410004 Digital Clamp Meter is a versatile and reliable tool designed for precise electrical measurements. Featuring a high-resolution 6000-count display, it offers comprehensive capabilities including AC current, AC/DC voltage, resistance, capacitance, frequency, diode testing, and temperature measurement. Its user-friendly design incorporates a data hold function, backlight, and built-in flashlight for enhanced visibility and safe operation in various environments. This manual provides essential information for safe and effective use of your clamp mita.
2. Alaye Aabo
Always adhere to safety precautions when using electrical testing equipment.
- CAT III 1000V, CAT IV 600V Safety Rating: This device is rated for Category III installations up to 1000V and Category IV installations up to 600V. Ensure you understand these ratings and do not exceed them.
- Non-Olubasọrọ Voltage (NCV) Iwari: Use the NCV feature to detect live wires without physical contact, enhancing safety.
- Ṣayẹwo Ṣaaju Lilo: Kí o tó lo gbogbo ìgbà, ṣe àyẹ̀wò mita náà, dán àwọn ìtọ́sọ́nà wò, àti àwọn ohun èlò míìrán fún ìbàjẹ́ èyíkéyìí. Má ṣe lò ó bí ó bá bàjẹ́.
- Yiyan Iṣẹ Ti o tọ: Always select the correct function and range for your measurement to prevent damage to the meter or injury.
- Yẹra fún àwọn Circuit Live: Do not measure resistance, continuity, or diode on live circuits.
- Wọ Ohun elo Idaabobo Ti ara ẹni (PPE): Always wear appropriate safety glasses and insulated gloves when working with electrical circuits.
- Jeki Gbẹgbẹ: Do not use the meter in wet environments.
- Aabo Batiri: Ensure batteries are correctly installed. Replace batteries when the low battery indicator appears.
3. Awọn ẹya Ọja
- High-Resolution 6000 Counts Display: Provides clear and accurate readings, even in varying light conditions.
- Awọn agbara Iwọn Iwọn pipe: Measures AC current, AC/DC voltage, resistance, capacitance, frequency, diode, and temperature.
- Apẹrẹ Ọrẹ olumulo: Includes a data hold function to freeze readings, a backlight for low-light visibility, and a built-in flashlight for illuminating work areas.
- Idaabobo Apọju: Equipped with double fuses for enhanced safety and durability.
- Non-Olubasọrọ Voltage (NCV) Iwari: Ó ń ṣàwárí ìpele AC láìléwutage lai taara olubasọrọ.
- Apẹrẹ to gbe: Comes with a carrying bag for convenient storage and transportation.
4. Ọja Ipariview
Familiarize yourself with the components of your TOTAL TMT410004 Digital Clamp Mita.

Nọmba 4.1: Iwaju view of the TOTAL TMT410004 Digital Clamp Meter, showing the display, rotary dial, function buttons, clamp jaws, and test lead input ports.

Nọmba 4.2: Illustration of the meter's multi-function and auto-ranging capabilities, including voltage, ìṣàn agbára, resistance, capacitance, àti àwọn ìwọ̀n ìgbàkúgbà.
5. Eto ati isẹ
5.1 Fifi sori batiri
The meter requires batteries for operation. Refer to the battery compartment on the back of the device for proper installation. Ensure correct polarity.
5.2 Gbogbogbo isẹ
- Titan/Apapa: Turn the rotary dial from "OFF" to the desired measurement function to power on the meter. Turn back to "OFF" to power off.
- Aṣayan iṣẹ-ṣiṣe: Use the rotary dial to select the primary measurement type (e.g., V~ for AC Voltage, A~ fún AC Current).
- Range Selection (Auto-Ranging): The TMT410004 features auto-ranging, which automatically selects the appropriate measurement range.
- "FUNC" Button: Press the "FUNC" button to cycle through sub-functions within a selected rotary dial position (e.g., AC/DC voltage, diode / itesiwaju).
- Bọ́tìnì "DÍ": Tẹ bọtini "DÍDÁ" lati di kika lọwọlọwọ lori ifihan naa. Tẹ lẹẹkansi lati tu silẹ.
- Imọlẹ afẹyinti/Imọlẹ: The meter includes a backlight for the display and a built-in flashlight. Activate these features as needed for improved visibility.
5.3 Specific Measurement Instructions
5.3.1 AC Wiwọn lọwọlọwọ (Clamp Iṣẹ́)
To measure AC current, ensure the rotary dial is set to an AC current range (e.g., 60/600A or Inrush 1000A). Open the clamp jaws by pressing the trigger and enclose only one conductor of the circuit. The reading will appear on the display.

Nọmba 5.1: Measuring AC current by clamping ni ayika kan nikan adaorin.
5.3.2 AC / DC Voltage Idiwon
Insert the red test lead into the "VΩmA" input jack and the black test lead into the "COM" input jack. Set the rotary dial to "V~" for AC voltage or "V-" for DC voltage. Connect the test probes across the circuit or component to be measured. Read the voltage iye lori ifihan.
5.3.3 Resistance Wiwọn
Ensure the circuit is de-energized. Insert the red test lead into the "VΩmA" input jack and the black test lead into the "COM" input jack. Set the rotary dial to "Ω". Connect the test probes across the component. Read the resistance value on the display.
5.3.4 Igbeyewo Ilọsiwaju
Ensure the circuit is de-energized. Insert the red test lead into the "VΩmA" input jack and the black test lead into the "COM" input jack. Set the rotary dial to the continuity/diode position and press "FUNC" until the continuity symbol ())) is displayed. Connect the test probes across the circuit. A continuous beep indicates continuity.
5.3.5 Idanwo Diode
Ensure the circuit is de-energized. Insert the red test lead into the "VΩmA" input jack and the black test lead into the "COM" input jack. Set the rotary dial to the continuity/diode position and press "FUNC" until the diode symbol (→|) is displayed. Connect the red probe to the anode and the black probe to the cathode of the diode. The forward voltage drop will be displayed. Reverse the probes; an open circuit (OL) indicates a good diode.
5.3.6 Iwọn Agbara
Ensure the capacitor is discharged before testing. Insert the red test lead into the "VΩmA" input jack and the black test lead into the "COM" input jack. Set the rotary dial to the capacitance position. Connect the test probes across the capacitor. Read the capacitance value on the display.
5.3.7 Ìwọ̀n Ìgbòkègbodò/Ìyípo Iṣẹ́
Insert the red test lead into the "VΩmA" input jack and the black test lead into the "COM" input jack. Set the rotary dial to the Hz/% position. Connect the test probes to the signal source. The frequency (Hz) or duty cycle (%) will be displayed. Use the "FUNC" button to switch between frequency and duty cycle.
5.3.8 Wiwọn iwọn otutu
Insert the temperature probe into the "VΩmA" and "COM" input jacks, ensuring correct polarity. Set the rotary dial to the °C/°F position. The ambient temperature will be displayed. Place the probe tip on or near the object whose temperature you wish to measure. The display will show the temperature in Celsius or Fahrenheit.

Nọmba 5.2: Using the temperature probe to measure the temperature of a liquid.
5.3.9 Non-olubasọrọ Voltage (NCV) erin
Set the rotary dial to the "NCV/LIVE" position. Move the top of the clamp meter near the conductor or outlet. The meter will beep and an LED will light up (green for low voltage, red for high voltage) to indicate the presence of AC voltage lai taara olubasọrọ.

Nọmba 5.3: NCV detection showing green LED for low voltage and red LED for high voltage.
6. Itọju
- Ninu: Fi aṣọ gbígbẹ tí ó rọ, nu mita náà. Má ṣe lo àwọn ohun ìpara tàbí àwọn ohun èlò ìfọ́mọ́ra.
- Rirọpo Batiri: When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate readings.
- Ibi ipamọ: If the meter is not used for an extended period, remove the batteries to prevent leakage. Store in a cool, dry place away from direct sunlight.
- Rirọpo Fuse: The meter is equipped with double fuses for overload protection. If a fuse blows, replace it with a fuse of the same type and rating. Refer to the specifications for fuse details.

Nọmba 6.1: Ti abẹnu view highlighting the double fuse protection.
7. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Mita ko ni agbara lori. | Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ. | Ṣayẹwo fifi sori batiri; ropo awọn batiri ti o ba wulo. |
| "OL" displayed during measurement. | Overload or open circuit. | Ensure the measurement range is appropriate. Check for open circuits. |
| Awọn kika ti ko pe. | Low battery, incorrect function/range, or environmental interference. | Replace batteries, select correct function/range, move away from strong electromagnetic fields. |
| Ko si ohun orin ilosiwaju. | Open circuit or incorrect function selected. | Check the circuit for breaks. Ensure continuity mode is selected. |
8. Awọn pato
| Sipesifikesonu | Iye |
|---|---|
| Nọmba awoṣe | TMT410004 |
| Ifihan | LCD 6000 Counts |
| AC Voltage | Titi di 750V |
| DC Voltage | Titi di 1000V |
| AC Lọwọlọwọ | Titi di 1000A |
| Atako | Títí dé 60MΩ |
| Agbara | Títí dé 100mF |
| Igbohunsafẹfẹ | Titi di 10MHz |
| Iwọn otutu | -20°C si 1000°C |
| Aabo Rating | CAT III 1000V, CAT IV 600V |
| Orisun agbara | Agbara Batiri (Awọn batiri ko si) |
| Iwọn Nkan | 690 g |
| Ọja Mefa | 28 x 6 x 13 cm |
9. Atilẹyin ọja ati Support
For warranty information and technical support, please refer to the documentation included with your product or visit the official TOTAL webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira.
Olupese: Lapapọ
Olubasọrọ: Refer to the official TOTAL website or product packaging for customer service contact details.