ERICKHILL ROOK50

ERICKHILL Infrared Thermometer

Model: ROOK50

Non-Contact Laser Temperature Gun

Ọrọ Iṣaaju

O ṣeun fun riraasing the ERICKHILL Infrared Thermometer. This device is designed for safe, non-contact temperature measurement of various surfaces. It features high precision, a wide temperature range, adjustable emissivity, and a clear LCD display. Please read this manual thoroughly before use to ensure proper operation and safety.

Alaye Aabo

This section contains important safety warnings and precautions. Always adhere to these guidelines to prevent injury or damage to the device.

Infrared thermometer being pointed at a person's forehead with a red 'no' symbol over it.
Image: The ERICKHILL Infrared Thermometer is not suitable for measuring human body temperature. A clear red 'no' symbol indicates this restriction.

Ọja irinše

Package pẹlu awọn nkan wọnyi:

Contents of the ERICKHILL Infrared Thermometer package, including the thermometer, user manual, and two AAA batteries.
Image: The ERICKHILL Infrared Thermometer, its user manual, and two AAA batteries as typically found in the product packaging.

Ṣeto

Follow these steps to prepare your thermometer for first use:

  1. Fifi sori batiri: Locate the battery compartment on the handle of the thermometer. Open the compartment cover and insert two AAA batteries, ensuring correct polarity (+/-). Close the cover securely.
  2. Agbara Tan: Press the 'SCAN' trigger to power on the device. The LCD display will illuminate.
ERICKHILL Infrared Thermometer with its LCD display showing '68.2' and two AAA batteries beside it.
Image: The ERICKHILL Infrared Thermometer and the two AAA batteries required for operation.

Awọn ilana Iṣiṣẹ

Learn how to use your infrared thermometer effectively:

Ipilẹ Wiwọn

  1. Point the thermometer at the target surface.
  2. Press and hold the 'SCAN' trigger. The laser pointer will activate, indicating the measurement area.
  3. Iwọn otutu kika yoo han lori iboju LCD.
  4. Release the trigger to hold the reading on the display. The device will automatically power off after 12 seconds of inactivity to conserve battery life.

Oye Ifihan naa

The LCD display provides various indicators and readings:

Close-up of the ERICKHILL Infrared Thermometer's LCD screen showing various indicators like HOLD, SCAN, AT, CAL, EMS, LOW, MAX, MIN, HI, and temperature units.
Aworan: Alaye view of the LCD screen, highlighting different modes and indicators such as HOLD, SCAN, Emissivity (EMS), and temperature limits (LOW, MAX, MIN, HI).

Switching Temperature Units (℃/℉)

Press the '℃/℉' button to toggle between Celsius and Fahrenheit temperature units.

Ṣatunṣe Emissivity

Emissivity (EMS) is the ability of a material to emit thermal energy. Different materials have different emissivities. This thermometer allows you to adjust the emissivity from 0.1 to 1.0 for more accurate readings on various surfaces.

  1. Press the 'MODE' button until 'EMS' appears on the display.
  2. Use the 'Up' and 'Down' arrow buttons to adjust the emissivity value.
  3. Press 'MODE' again to confirm and exit.

Itaniji giga / Kekere

The device can be set to alert you when the measured temperature exceeds a high limit or falls below a low limit.

Diagram showing how to set high and low temperature alarms on the ERICKHILL Infrared Thermometer, with visual indicators for normal, low, and high temperature states.
Image: Instructions for setting high and low temperature alarm limits, and how the thermometer indicates these states visually.
  1. Press the 'MODE' button repeatedly until 'HI' or 'LOW' appears.
  2. Use the 'Up' and 'Down' arrow buttons to set the desired high or low temperature limit.
  3. Press 'MODE' again to confirm and exit.
  4. When the measured temperature exceeds the 'HI' limit or falls below the 'LOW' limit, the alarm indicator will flash.

Idiwọn Ijinna-si-Aami (D:S)

The ERICKHILL ROOK50 has a Distance-to-Spot ratio of 12:1. This means that at a distance of 12 units from the target, the measurement spot diameter will be 1 unit. For example, if you are 12 inches away from the target, the measurement area will be a 1-inch circle. To ensure accurate readings, make sure the target area is larger than the spot size.

Two ERICKHILL infrared thermometers measuring a surface, demonstrating high accuracy with a laser pointer indicating the measurement spot.
Image: Two ERICKHILL infrared thermometers in use, illustrating the precision of temperature measurement with a laser guide.

Awọn ohun elo Aṣoju

ERICKHILL Infrared Thermometer being used to measure the temperature of an engine in a vehicle.
Image: The ERICKHILL Infrared Thermometer is suitable for various applications, including vehicle repair and inspection, to quickly assess surface temperatures.

This thermometer is versatile and can be used for:

Itoju

Proper care will ensure the longevity and accuracy of your thermometer:

Laasigbotitusita

If you encounter issues with your thermometer, refer to the following common problems and solutions:

IsoroOwun to le FaOjutu
Ko si ifihan/Ẹrọ ko ni tan-anAwọn batiri ti o ku tabi ti ko tọṢayẹwo polarity batiri tabi ropo pẹlu awọn batiri AAA tuntun.
Awọn kika ti ko peIncorrect emissivity setting; Lens is dirty; Target too small or too far; Measuring transparent objectAdjust emissivity for the material; Clean the lens; Ensure target is within D:S ratio; Do not measure transparent objects.
Lesa ko ṣiṣẹLaser function disabled (if applicable); Device malfunctionEnsure laser is enabled (if there's a setting); Contact customer support if issue persists.

Awọn pato

ParamitaIye
Iwọn otutu-50 ℃ si 600 ℃ (-58 si 1112 ℉)
Yiye±1.5℃ or ±1.5% (whichever is greater)
Distance Spot Ratio (D:S)12:1
Emissivity0.1 to 1.0 (Adjustable)
Akoko Idahun0.5 aaya
Agbara Aifọwọyi Pa a12 aaya ti aiṣiṣẹ
Lesa KilasiKilasi 2
Ibi ti ina elekitiriki ti nwa2 x Awọn batiri AAA (pẹlu)
Iwọn220 giramu
Awọn iwe-ẹriFDA, FCC, RoHS, UKCA, CE Compliant

Atilẹyin ọja ati Support

ERICKHILL provides comprehensive support for its products:

Awọn iwe aṣẹ ti o jọmọ - ROOK50

Ṣaajuview ERICKHILL ROOK 400/600 SP IR Itanwo Itọsọna olumulo
Itọsọna olumulo fun ERICKHILL ROOK 400 SP ati ROOK 600 SP infurarẹẹdi thermometers. Pese awọn itọnisọna lori iṣẹ, awọn ẹya, ailewu, ati awọn alaye imọ-ẹrọ.
Ṣaajuview ERICKHILL ER02 EMF Mita Itọsọna olumulo
Ṣawari awọn agbara ti ERICKHILL ER02 EMF Mita pẹlu itọnisọna olumulo okeerẹ yii. Kọ ẹkọ nipa iṣẹ ṣiṣe 3-in-1 rẹ fun wiwọn ina, oofa, ati awọn aaye igbohunsafẹfẹ redio, pẹlu iṣẹ ṣiṣe, awọn pato, ati awọn itọnisọna ailewu.
Ṣaajuview Erickhill RT-100S EMF Mita olumulo Afowoyi
Itọsọna olumulo fun Erickhill RT-100S EMF Mita, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, awọn alaye imọ-ẹrọ, ati awọn ohun elo fun wiwọn ina, oofa, ati awọn aaye RF.