Waveshare RS232/485/422 TO POE ETH Converter(B)

Waveshare RS232/485/422 to RJ45 Ethernet Module User Manual

Awoṣe: RS232/485/422 TO POE ETH Converter(B)

Brand: Waveshare

1. Ifihan

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Waveshare RS232/485/422 to RJ45 Ethernet Module. This device functions as an industrial-grade data acquisitor and IoT gateway, designed for robust performance in various environments. It integrates multiple functionalities, including serial server capabilities, Modbus gateway, MQTT gateway, and RS485 to JSON conversion, facilitating bi-directional transparent data transmission between serial devices and Ethernet networks.

The module is equipped with RS232/485/422 and Ethernet ports, supporting Power over Ethernet (PoE) functionality. It offers flexible power input options via a DC port (5.5mm outer, 2.1mm inner diameter) and screw terminals. Its compact design includes rail-mount support for easy installation in industrial settings.

2. Ọja Ipariview ati Awọn ẹya ara ẹrọ

The Waveshare RS232/485/422 to RJ45 Ethernet Module is engineered for industrial applications, offering reliable serial-to-Ethernet conversion with advanced features.

Awọn ẹya pataki:

Waveshare RS232/485/422 to RJ45 Ethernet Module

Figure 1: Waveshare RS232/485/422 to RJ45 Ethernet Module, showing the Ethernet and RS232 ports.

Features at a Glance and Specifications of Waveshare Ethernet Module

Olusin 2: Pariview of the module's features and a summary of its technical specifications.

Primary Function, Interfaces, Power Methods, Rail-Mount, and Modbus Gateway Support

Figure 3: Illustrates the primary function of bi-directional data transmission, various interface options, power supply methods (PoE, DC, screw terminal), rail-mount capability, and Modbus gateway support.

Multi Communication Modes, MQTT/JSON to Modbus, Multi Hosts Roll-Polling, User-Defined Packets

Figure 4: Details the supported communication modes (TCP Server/Client, UDP), the MQTT/JSON to Modbus conversion process, multi-host roll-polling functionality, and the use of user-defined heartbeat/registration packets.

NTP Protocol Support, Multiple Protection, Configuration Methods, Aluminium Alloy Enclosure

Figure 5: Highlights NTP protocol support for time synchronization, various protection features (digital isolation, ESD, over-current, over-voltage, TVS), different configuration methods (Hosts, Web Browser, Device Management Functions Library), and the durable aluminum alloy enclosure.

Interface Introduction and Outline Dimensions

Figure 6: Provides a detailed introduction to the module's interfaces, including the RS232 port, PoE Ethernet port, DC power port, 6-36V power input, ground, signal ground, RS485/422 terminals, and the RS232 pinout definition. Also includes outline dimensions in millimeters.

3. Eto

Proper setup is crucial for the stable operation of the Waveshare Ethernet Module. Follow these steps for initial installation and configuration.

3.1 Ipese Agbara

The module supports multiple power input methods:

Refer to Figure 3 for visual representation of power supply options.

3.2 Ti ara Awọn isopọ

Connect your devices to the module as follows:

Refer to Figure 6 for detailed interface introduction and pinout diagrams.

3.3 Iṣeto ni ibẹrẹ

The module can be configured via dedicated software (VirCom) or a web browser interface. Initial setup often requires direct connection to a PC.

  1. Software Configuration (Recommended for initial setup):
    • Download the "VirCom English" software from the official Waveshare website, specifically for the "RS232/485/422 TO POE ETH (B)" model.
    • Connect your PC directly to the module's Ethernet port. Alternatively, use an RS232 to USB cable to connect to the module's RS232 port for initial access.
    • Launch the VirCom software. Use the "Device" button to discover the module on your network.
    • Configure network settings (e.g., set IP Mode to DHCP or assign a static IP address that avoids conflicts with your network gateway, typically 192.168.1.254 is a common default that might conflict).
    • Adjust serial port parameters (Baud rate, Parity, Data bits, Flow control) to match your connected serial device.
    • Save settings by clicking "Modify Device" or "Download" (for firmware/config changes).
  2. Web Iṣeto ẹrọ aṣawakiri:
    • Once the module has an accessible IP address on your network, open a web browser and enter the module's IP address.
    • Log in using the default credentials (refer to Waveshare documentation if unknown).
    • Configure network and serial parameters through the web interface. Note that some advanced settings, such as MQTT configuration, might only be available via the VirCom software.

It is highly recommended to consult the detailed documentation available on the Waveshare website for specific software usage and advanced configuration options.

4. Awọn ilana Iṣiṣẹ

The Waveshare Ethernet Module supports various operational modes to suit different application requirements.

4.1 Awọn ọna ibaraẹnisọrọ

The module can operate in the following modes:

Refer to Figure 4 for diagrams illustrating these communication modes.

4.2 Modbus Gateway Functionality

The module can act as a Modbus gateway, facilitating communication between Modbus TCP and Modbus RTU devices. This is particularly useful for integrating older Modbus RTU serial devices into modern Ethernet-based Modbus TCP networks. Configuration is typically done using specific software.

Refer to Figure 3 for an illustration of Modbus Gateway support.

4.3 MQTT/JSON to Modbus

The module supports flexible protocol conversion, including MQTT/JSON to Modbus. This allows data from serial devices to be acquired, formatted into JSON, and then published to an MQTT server. Conversely, messages from the MQTT server can be converted from JSON to Modbus commands for serial devices. This feature is essential for IoT applications and cloud communication.

Refer to Figure 4 for a conceptual diagram of MQTT/JSON to Modbus conversion.

4.4 Multi-Host Roll-Polling

This feature allows the module to identify and respond to different network devices individually, preventing crosstalk issues when communicating with multiple devices on the same network. This ensures reliable data exchange in complex network environments.

Refer to Figure 4 for an illustration of multi-host roll-polling.

4.5 User-Defined Heartbeat/Registration Packet

For enhanced cloud communication and device identification, the module supports user-defined heartbeat and registration packets. These packets can be configured to periodically send status information or register the device with a central server.

Refer to Figure 4 for a visual representation of user-defined packets.

4.6 NTP Protocol Support

The module can utilize the Network Time Protocol (NTP) to obtain accurate network time information. This time data can be used for timestamping serial output or data uploads, ensuring data integrity and synchronization across systems.

Refer to Figure 5 for an illustration of NTP protocol support.

5. Itọju

The Waveshare Ethernet Module is designed for industrial reliability and requires minimal maintenance. Adhering to these guidelines will help ensure its longevity and optimal performance:

No user-serviceable parts are inside the module. Do not attempt to open the enclosure, as this may void the warranty and could lead to electric shock.

6. Laasigbotitusita

This section provides solutions to common issues encountered with the Waveshare RS232/485/422 to RJ45 Ethernet Module.

6.1 Gbogbogbo Laasigbotitusita Igbesẹ

If issues persist after following these steps, please refer to the official Waveshare documentation or contact technical support.

7. Awọn pato

Detailed technical specifications for the Waveshare RS232/485/422 to RJ45 Ethernet Module:

Ẹya ara ẹrọSipesifikesonu
Ọja IruSerial server, Modbus gateway, MQTT gateway
Ipilẹ IšėBi-directional transparent data transmission between RS232/485/422 and Ethernet
Ibaraẹnisọrọ InterfaceRS232 port × 1; RS485 port × 1; RS422 port × 1; Ethernet port × 1
Ibi ti ina elekitiriki ti nwaDC power port, 6 - 36V DC screw terminal, or PoE port
Idaabobo IdaaboboPower isolation, Signal isolation
ÀjọlòPoE network port, support IEEE 802.3af standard, 10 / 100M auto-negotiation RJ45 connector, 2 KV surge protection
Serial PortIsolated RS232/485/422
Ṣàyẹ̀wò300 - 115200 bps
Bit Paritynone, odd, even, mark, space
Bit data5 - 9 bits
Iṣakoso sisanN/A
IlanaETHERNET, IP, TCP, UDP, HTTP, ARP, ICMP, DHCP, DNS
Ọna iṣeto niHost, web browser, device management functions library
Ọna IbaraẹnisọrọTCP/IP direct communication, VCOM
Ipo IṣiṣẹTCP server, TCP client (coexisting with TCP server), UDP, UDP multicast
Awọn iwọn otutu ti nṣiṣẹ-40°C ~ 85°C
Ibiti ọriniinitutu5% ~ 95% ọriniinitutu ojulumo
Awọn iwọn (L×W×H)88.7 × 72.5 × 24.2 mm (excluding rail-mount buckle)
Iwọn NkanIsunmọ 5.3 iwon (150 giramu)

Note: Some specifications are derived from the product images and feature bullets for completeness.

8. atilẹyin ọja Information

Specific warranty details for the Waveshare RS232/485/422 to RJ45 Ethernet Module are not provided within this document. For information regarding product warranty, including terms, duration, and claim procedures, please refer to the official Waveshare website or contact their customer service directly. It is advisable to retain your purchase receipt as proof of purchase for any warranty claims.

9. Atilẹyin

For further assistance, technical support, or additional documentation, please utilize the following resources:

Awọn iwe aṣẹ ti o jọmọ - RS232/485/422 TO POE ETH Converter(B)

Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Ẹ̀rọ Ìṣiṣẹ́ Wavesshare RS232/485 sí WiFi PoE Ethernet (B)
Ṣawari Waveshare RS232/485 si WiFi PoE Ethernet (B), itọsọna pipe fun olupin tẹlentẹle ti o yi RS232/485 pada si awọn isopọ nẹtiwọọki TCP/IP, ti o mu ki gbigbe data meji nipasẹ WiFi ati Ethernet ṣiṣẹ.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Waveshare UART TO ETH (B): Ìtọ́sọ́nà Olùyípadà Serial to Ethernet
Ìwé ìtọ́ni tó péye fún ẹ̀rọ Waveshare UART TO ETH (B), tó ṣàlàyé àwọn ohun tó wà nínú ẹ̀rọ náà gẹ́gẹ́ bí ẹ̀rọ ìyípadà UART sí Ethernet, ẹnu ọ̀nà IoT, ẹnu ọ̀nà Modbus, àti ẹ̀rọ ìṣiṣẹ́ fún àwọn ohun èlò ilé iṣẹ́.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Ìyípadà Waveshare RS232/485 sí Ethernet
Èyí jẹ́ ẹ̀rọ RS232/485 sí Ethernet tó wà ní ìpele iṣẹ́ láti Waveshare, tó ń jẹ́ kí ìgbésẹ̀ data tó ṣe kedere láàárín àwọn ibudo Ethernet RS232, RS485, àti RJ45 ṣeé ṣe. Ó ní ẹ̀rọ isise ARM M4 32-bit, 10/100M Ethernet, ọ̀pọ̀lọpọ̀ ọ̀nà ìṣiṣẹ́ (TCP Server/Client, UDP, HTTPD), ẹnu ọ̀nà Modbus, àti Webatilẹyin iho, nfunni ni iyara giga, agbara kekere, ati iduroṣinṣin fun awọn ohun elo IoT ile-iṣẹ.
Ṣaajuview Waveshare RS485 to WiFi/ETH MQTT Communication User Manual
Comprehensive user manual for the Waveshare RS485 to WiFi/ETH module, guiding users through software and hardware preparation, network configuration, and establishing MQTT communication with platforms like EMQX.
Ṣaajuview RS232/RS485 sí Ethernet & PoE Ethernet Gateway Ìlànà Ìmọ̀-ẹ̀rọ
Ìwé yìí pèsè àwọn àlàyé pàtó, àwọn ẹ̀yà ara ẹ̀rọ àti sọ́fítíwètì, àti àwọn ìlànà ìdánwò fún àwọn ẹnu ọ̀nà Waveshare RS232/RS485 sí Ethernet àti PoE Ethernet. Àwọn ẹ̀rọ wọ̀nyí ń ṣiṣẹ́ gẹ́gẹ́ bí àwọn olupin onípele, àwọn ẹnu ọ̀nà Modbus, àti àwọn ẹnu ọ̀nà MQTT fún gbígbà dátà ilé iṣẹ́ àti ìsopọ̀mọ́ra IoT.
Ṣaajuview Waveshare RS485 TO ETH (B) User Manual - Industrial RS485 to Ethernet IoT Gateway
Comprehensive user manual for the Waveshare RS485 TO ETH (B), an industrial serial device server and IoT gateway. Learn about its features, applications, configuration, and how to connect RS485 devices to Ethernet for Modbus, MQTT, and cloud integration.