Ọrọ Iṣaaju
This manual provides instructions for the installation, operation, and maintenance of the AC Infinity Window Duct Kit, Model AC-WVK5. This kit is designed to facilitate ventilation by providing a secure and adaptable port for inline fans, air conditioners, and dryers to exhaust or intake air through a window or sliding door.
The AC-WVK5 is constructed for durability and offers flexible installation options to fit various window sizes and ducting requirements.
Awọn irinše to wa
The AC Infinity Window Duct Kit includes the following parts:
- Adjustable Main Plate (Window Panel)
- Adaptable Base Coupler
- Duct Adapters (for 4" and 6" ducting)

Image: The main plate, adaptable base coupler, and duct adapters are shown, illustrating the kit's components.
Eto ati fifi sori
- Ṣetan Ferese naa: Ensure the window or sliding door opening is clean and clear of obstructions.
- Adjust the Window Panel: The main plate is adjustable and can be extended to fit various window sizes, both vertically and horizontally. Slide the rail to match the width or height of your window opening.
- Install the Window Panel: Place the adjusted window panel securely into the window frame. Close the window against the panel to create a tight seal. For optimal sealing, additional weather stripping (not included) may be applied around the edges of the panel.
- Attach the Base Coupler: Secure the adaptable base coupler to the opening in the window panel. This coupler provides a universal connection point.
- Select and Attach Duct Adapter: Choose the appropriate duct adapter (4-inch or 6-inch) based on your inline fan or hose size. Fasten the selected adapter onto the base coupler. The kit is compatible with standard 4" and 6" ducting, as well as 5.1" and counterclockwise 5.9" AC hoses.
- Connect Ducting/Hose: Connect your inline fan ducting or AC hose to the installed adapter. Ensure a secure connection to prevent air leaks.

Image: This diagram illustrates how the window duct kit can be installed flexibly in both vertical and horizontal window orientations.

Image: This image demonstrates the connection process for both 4/6 inch ducting and 5.1/5.9 inch HVAC hosing to the kit's base coupler.
Awọn ilana Iṣiṣẹ
The AC Infinity Window Duct Kit functions as a passive port for air exchange. Its operation is dependent on the connected ventilation device (e.g., inline fan, air conditioner, dryer).
- Iṣẹ eefi: When connected to an exhaust fan or dryer, the kit facilitates the removal of stale air, odors, or hot air from an indoor space to the outside environment.
- Intake Function: When connected to an intake fan, the kit allows for the drawing of fresh outside air into an indoor space.
Ensure that the connected device is operated according to its own instruction manual. The window duct kit provides the physical interface for air transfer.

Image: This illustration shows the window duct kit providing outdoor access for an inline fan, facilitating air exhaust from a grow tent.

Image: A practical setup showing ducting from a grow tent routed through the window duct kit.
Itoju
To ensure optimal performance and longevity of your AC Infinity Window Duct Kit, follow these simple maintenance guidelines:
- Ninu igbagbogbo: Periodically wipe down the window panel and adapters with a damp asọ lati yọ eruku ati idoti. Yago fun abrasive ose.
- Ṣayẹwo Awọn edidi: Regularly check the seal between the window panel and your window frame. Reapply weather stripping if necessary to maintain an airtight connection.
- Ṣayẹwo Awọn isopọ: Ensure that all ducting and hose connections to the adapters remain secure.
- Ibi ipamọ asiko: If removing the kit for seasonal storage, clean all components thoroughly and store them in a dry, protected area.
Laasigbotitusita
If you encounter issues with your AC Infinity Window Duct Kit, consider the following common solutions:
- Poor Seal/Air Leaks:
- Ensure the window panel is fully extended and tightly secured within the window frame.
- Inspect for gaps around the panel and apply additional weather stripping or foam tape to improve the seal.
- Verify that the ducting/hose is securely fastened to the adapter.
- Ducting/Hose Not Fitting:
- Confirm you are using the correct adapter for your ducting (4-inch or 6-inch).
- For AC hoses, ensure compatibility with 5.1" or counterclockwise 5.9" sizes.
- Panel Not Fitting Window:
- Ensure the adjustable rail is fully extended or retracted to match your window dimensions.
- The kit is designed for most standard windows and sliding doors; verify your window dimensions against the product specifications.
Awọn pato
| Awoṣe | AC-WVK5 |
| Olupese | AC Ailopin |
| Main Plate Length | 16.9 inches (43.0 cm) |
| Main Plate Width | 6.4 inches (16.3 cm) |
| Full Extension Length | Titi di inṣi 61.0 (154.9 cm) |
| Ducting Compatibility | Inch 4 ati inch 6 |
| Hosing Compatibility | 5.1 inch and 5.9 inch (counterclockwise) |
| Iwọn Nkan | 3.91 iwon |
| Ọja Mefa | 16.91 x 6.42 x 0.71 inches (kò ní ìtẹ̀síwájú) |

Image: This image provides detailed measurements for the window panel and duct adapters, including their dimensions and extension range.
Atilẹyin ọja ati Support
For warranty information or technical support regarding your AC Infinity Window Duct Kit, please refer to the official AC Infinity webojula tabi kan si wọn onibara iṣẹ taara. Tọju iwe-ẹri rira rẹ fun awọn ẹtọ atilẹyin ọja.
AC Infinity Contact Information:
Webojula: www.acinfinity.com
(Jọwọ ṣe ayẹwo webojú òpó wẹ́ẹ̀bù fún àwọn àlàyé ìbánisọ̀rọ̀ tuntun àti àwọn àṣàyàn ìrànlọ́wọ́.)





