GoodWe 3648-EM / 0131662

Ìwé Ìtọ́sọ́nà Olùlò Inverter Aláwọ̀ Gíga GoodWe 3648-EM

Model: 3648-EM / 0131662

Ọrọ Iṣaaju

This manual provides essential information for the safe and efficient operation, installation, and maintenance of the GoodWe 3648-EM Hybrid Inverter. Please read this manual thoroughly before installation and operation, and keep it for future reference.

The GoodWe 3648-EM is a high-performance hybrid inverter designed for residential and light commercial solar energy systems, integrating solar power generation, battery storage, and grid connection capabilities.

Ọja Pariview

The GoodWe 3648-EM Hybrid Inverter system includes the main inverter unit and a three-phase Smart Meter for comprehensive energy management.

GoodWe 3648-EM Hybrid Inverter and Smart Meter

Figure 1: GoodWe 3648-EM Hybrid Inverter (top) and accompanying Smart Meter (bottom left).

This image displays the primary components of the GoodWe 3648-EM system. The larger unit is the hybrid inverter, characterized by its white casing and black control panel with indicator lights. Below and to the left is the compact Smart Meter, designed for DIN rail mounting, also in a white casing with a small display and indicator lights.

Iwaju view of GoodWe 3648-EM Hybrid Inverter

olusin 2: Iwaju view of the GoodWe 3648-EM Hybrid Inverter.

This image shows a detailed front view of the GoodWe 3648-EM Hybrid Inverter. The front panel features a series of LED indicators and buttons for status monitoring and basic control. The GoodWe logo is visible on the right side of the control panel.

GoodWe Smart Meter close-up

olusin 3: Isunmọ view of the GoodWe Smart Meter.

This image provides a close-up of the GoodWe Smart Meter, a compact device with a small digital display and several indicator lights (power, communication, status). It is designed for integration into electrical panels to monitor energy flow.

Imọ ni pato

Table 1: GoodWe 3648-EM Hybrid Inverter Specifications
Ẹya ara ẹrọSipesifikesonu
AwoṣeGW3648-EM
Ti won won Agbara3.68 kVA
Backup Power (Single-phase)5.0 kW
MPP Trackers2
MPPT Voltage Ibiti280-500 V DC
Max. Gbigba agbara Lọwọlọwọ50 DC
IbaraẹnisọrọWi-Fi, Integrated Web Olupin
Smart MitaThree-phase included
Awọn iwọn (W x H x D)347 x 432 x 175 mm
Kilasi IdaaboboIP65
Iwọn17 kg

Awọn Itọsọna Aabo

Always adhere to local electrical codes and regulations. Installation and maintenance should only be performed by qualified personnel.

Fifi sori ẹrọ ati Eto

1. Unpacking ati ayewo

Carefully unpack the inverter and Smart Meter. Inspect all components for any signs of damage during transit. Report any damage to your supplier immediately.

2. Iṣagbesori Inverter

Choose a suitable mounting location that is:

Use the provided mounting bracket and hardware to securely fasten the inverter to a solid wall or frame.

3. Itanna Awọn isopọ

All electrical connections must comply with local wiring regulations and standards. Refer to the connection diagram below for guidance.

Ẹyìn view of GoodWe 3648-EM Hybrid Inverter with connection ports

olusin 4: Ẹyìn view of the GoodWe 3648-EM Hybrid Inverter showing connection ports.

This image displays the rear panel of the GoodWe 3648-EM Hybrid Inverter, highlighting its various connection terminals. These include inputs for PV strings (PV1, PV2), battery connections, grid connection (ON-GRID), backup load connection (BACK-UP), and communication ports (RS485, Meter). A large heat sink is visible at the bottom.

  1. Asopọ PV: Connect the positive and negative cables from your solar array to the PV1 and PV2 inputs. Ensure correct polarity.
  2. Asopọ batiri: Connect the battery bank to the dedicated battery terminals. Observe correct polarity (+/-).
  3. Asopọmọra akoj: Connect the inverter to the main electrical grid.
  4. Backup Load Connection: For critical loads, connect them to the backup output.
  5. Smart Meter Connection: Connect the three-phase Smart Meter as per the wiring diagram provided in the full installation guide.
  6. Ilẹ: Ensure the inverter chassis is properly grounded.

4. Communication Setup (Wi-Fi)

The inverter features integrated Wi-Fi for monitoring and configuration. Follow these general steps:

Ṣiṣẹ ẹrọ oluyipada

1. Ibẹrẹ Agbara-On

After all connections are secure and verified:

  1. Turn on the DC isolator switch for the PV array.
  2. Tan ẹ̀rọ fifọ batiri naa.
  3. Turn on the AC breaker from the grid.
  4. The inverter will perform a self-test and then begin operation. Observe the LED indicators on the front panel for status.

2. Abojuto

Monitor the inverter's performance via the integrated web server or the GoodWe monitoring app/platform. Key parameters to observe include:

3. Ilana tiipa

To safely shut down the inverter:

  1. Turn off the AC breaker from the grid.
  2. Pa batiri fifọ.
  3. Turn off the DC isolator switch for the PV array.
  4. Wait for all indicators on the inverter to turn off.

Itoju

Itọju deedee ṣe idaniloju iṣẹ ti o dara julọ ati igba pipẹ ti inverter rẹ.

Laasigbotitusita

This section provides basic troubleshooting steps for common issues. For complex problems, contact GoodWe technical support or a certified installer.

Table 2: Wọpọ Laasigbotitusita Guide
IsoroOwun to le FaOjutu
Inverter kò ṣiṣẹ́No DC input from PV or battery; AC grid disconnected; Emergency stop activated.Check all breakers and isolators (PV, battery, AC grid). Ensure emergency stop button is disengaged.
Iwọn agbara kekereShading on PV panels; Dirty PV panels; Inverter derating due to high temperature.Check for shading. Clean PV panels. Ensure adequate ventilation around the inverter.
Aṣiṣe ibaraẹnisọrọWi-Fi signal weak; Incorrect network settings; Router issue.Check Wi-Fi signal strength. Reconfigure network settings. Restart router.
Koodu aṣiṣe hanInternal fault; Grid fault; PV overvoltage / undervoltage.Note the error code and consult the full user manual or contact GoodWe support. Do not attempt repairs yourself.

Atilẹyin ọja ati Support

GoodWe products typically come with a standard warranty. Please refer to your purchase documentation or the official GoodWe webaaye fun awọn ofin ati ipo atilẹyin ọja kan pato ti o kan agbegbe ati awoṣe rẹ.

For technical support, warranty claims, or further assistance, please contact your installer or the official GoodWe support channels:

Awọn iwe aṣẹ ti o jọmọ - 3648-EM / 0131662

Ṣaajuview GoodWe EM Series arabara Inverter Afọwọṣe olumulo
Itọsọna olumulo yii n pese alaye alaye lori GoodWe EM Series Hybrid Inverters, pẹlu awọn awoṣe GW3048D-EM, GW3648D-EM, ati GW5048D-EM. O ni wiwa awọn abala pataki gẹgẹbi fifi sori ẹrọ, iṣẹ ṣiṣe, awọn iṣọra ailewu, laasigbotitusita, ati awọn alaye imọ-ẹrọ fun iṣapeye lilo agbara oorun, ibi ipamọ batiri, ati ibaraenisepo akoj.
Ṣaajuview GoodWe EM Series arabara Inverter Quick fifi sori Itọsọna
This quick installation guide provides essential instructions for the GoodWe EM Series Hybrid Inverter, including safety, electrical connections, and commissioning for models GW5048-EM, GW3648-EM, and GW3048-EM.
Ṣaajuview GOODWE ET Series arabara Inverter Afowoyi olumulo
Itọsọna olumulo pipe fun GOODWE ET Series Hybrid Inverters, fifi sori ẹrọ, iṣẹ ṣiṣe, ailewu, laasigbotitusita, ati awọn alaye imọ-ẹrọ fun awọn awoṣe bii GW5KL-ET, GW6KL-ET, GW8KL-ET, ati GW10KL-ET.
Ṣaajuview Problem PE-N Relay in GoodWe HV Hybrid Inverter: Analysis and Troubleshooting
Detailed analysis of PE-N relay issues in GoodWe HV Hybrid Inverters (ET 29.9) during grid loss and reconnection, including measurement setup, sequence diagrams, and oscilloscope data.
Ṣaajuview Atilẹyin ọja to lopin fun Eto Inverter GOODWE - Ọjà Brazil
Àwọn òfin àti ìlànà àtìlẹ́yìn tó kún rẹ́rẹ́ fún àwọn ètò ìyípadà GOODWE tí a tà ní ọjà Brazil, tó bo ìbòjú, àwọn ìyọkúrò, ìlànà ẹ̀tọ́, àti àwọn ìdíwọ̀n gbèsè.
Ṣaajuview GoodWe SolarGo App Afowoyi olumulo
Iwe afọwọkọ olumulo yii n pese awọn ilana alaye fun lilo Ohun elo GoodWe SolarGo lati ṣe atẹle ati ṣakoso awọn oluyipada oorun GoodWe. O ni wiwa fifi sori ẹrọ app, asopọ, iṣeto paramita, itọju ẹrọ, ati laasigbotitusita fun awọn awoṣe bii DNS, SDT G2, MT G2, SMT, ati jara HT.