1. Ifihan
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the DITEC LCU40H control unit. The LCU40H is designed for the automation of gates with one or two 24V DC motors, supporting up to 2 x 12A max. It features an intuitive display for easy configuration of operating modes and precise control over gate position and speed.
Pataki: This is a professional product. Installation by a qualified professional is mandatory and it is not compatible with DIY installation.
2. Alaye Aabo
Always adhere to local safety regulations and standards during installation and operation. Disconnect power before performing any maintenance or troubleshooting. This unit complies with standard 13849 regarding safety functions.
- Rí i dájú pé a ti ge ina mọnamọna kuro kí a tó ṣe iṣẹ́ ina mọnamọna.
- Awọn oṣiṣẹ ti o ni oye nikan yẹ ki o ṣe fifi sori ẹrọ ati itọju.
- Do not modify the control unit or its components.
- Pa awọn ọmọde ati awọn ohun ọsin kuro ni agbegbe ẹnu-ọna nigba iṣẹ.
- Regularly check safety devices (e.g., photocells, safety edges) for proper function.
3. Ọja Ipariview
The DITEC LCU40H control unit is a robust electronic board designed for reliable gate automation. It offers advanced features for precise control and enhanced safety.

Nọmba 3.1: Ita view of the DITEC LCU40H control unit, showing its compact and durable casing.

Nọmba 3.2: Ti abẹnu view of the DITEC LCU40H control unit, displaying the main circuit board, transformer, and terminal blocks for connections.
Awọn ẹya pataki:
- Supports 1 or 2 motors up to 12A (6A for LCU30H).
- Easy configuration via display.
- Control of gate position and speed.
- Adjustable acceleration, deceleration, and start times.
- Virtual encoder technology for constant impact force control and immediate obstacle detection.
- Pre-installed 433 MHz radio receiver module (switchable with 868 MHz module).
- Removable memory module.
- Green mode function for reduced power consumption (less than 1W).
- Provision for solar and/or hybrid power supply.
- IP55 plastic enclosure.
- Operating temperature: -35°C to +55°C (with NIO function).
4. Eto ati fifi sori
Installation of the DITEC LCU40H control unit must be performed by a certified professional. Refer to the detailed wiring diagrams provided with the product packaging for specific connections.
4.1. Fifi Ẹyọ Iṣakoso sori ẹrọ
- Choose a suitable location for the control unit, ensuring it is protected from direct weather exposure and easily accessible for maintenance.
- Mount the unit securely using appropriate fasteners. The dimensions are 357 x 238 x 120 mm (H x W x D).
4.2. Itanna Awọn isopọ
Ensure all power is disconnected before making any electrical connections.
- Ibi ti ina elekitiriki ti nwa: Connect the main power supply (230 VAC) to the designated terminals.
- Awọn Isopọ mọto: Connect the 24V DC motors to the respective motor output terminals. The unit supports up to two motors.
- Awọn Ẹrọ Aabo: Connect all required safety devices, such as photocells, safety edges, and emergency stop buttons, to their dedicated inputs.
- Àwọn Ẹ̀rọ Àṣẹ: Connect command devices like push buttons, key switches, or radio receivers.
- Awọn ẹya ara ẹrọ: Connect any optional accessories such as flashing lights or courtesy lights.
4.3. Initial Configuration and Auto-Learning
The Entrematic LCU series features an advanced auto-learning procedure for easy setup.
- After all connections are made, power on the unit.
- Follow the on-screen prompts on the integrated display to initiate the auto-learning process.
- The system will automatically detect and configure the gate's travel limits, acceleration, and deceleration parameters.
- Verify that the gate operates smoothly and correctly after the auto-learning process is complete.
5. Awọn ilana Iṣiṣẹ
The DITEC LCU40H control unit allows for flexible operation of your automated gate system.
5.1. Ipilẹ isẹ
- Nsii/Tiipa: Activate the gate using a connected command device (e.g., remote control, push button). A single command typically cycles the gate (open-stop-close-stop).
- Iduro: During gate movement, a second command will stop the gate.
- Yipada: If an obstacle is detected during closing, the gate will reverse its movement to ensure safety.
5.2. Advanced Settings (via Display)
The integrated display allows for fine-tuning of various parameters:
- Acceleration/Deceleration: Ṣatunṣe ramp-pa ati ramp-down speeds for smoother gate movement.
- Start/Stop Space: Configure the distance over which acceleration/deceleration occurs.
- Reinforcement Space: Set the distance for increased force at the beginning of movement.
- Pairing Speed: Adjust the speed at which the gate approaches its open and closed limits.
- Awọn ọna ṣiṣe: Select different operating modes (e.g., automatic closing, pedestrian opening).
Refer to the detailed programming manual (separate document) for specific menu navigation and parameter adjustments.
6. Itọju
Regular maintenance ensures the longevity and safe operation of your gate automation system.
6.1. Routine Checks (Monthly)
- Ayewo wiwo: Check the control unit casing for any signs of damage, corrosion, or water ingress.
- Awọn Isopọ USB: Verify that all electrical connections are secure and free from fraying or damage.
- Awọn Ẹrọ Aabo: Test all safety devices (photocells, safety edges) to ensure they function correctly and stop/reverse the gate when activated.
- Gbigbe ẹnu-ọna: Observe the gate's movement for any unusual noises, jerky movements, or signs of mechanical stress.
6.2. Professional Servicing (Annually)
It is recommended to have the system inspected and serviced by a qualified professional at least once a year. This includes:
- Thorough inspection of all electrical components and wiring.
- Checking and adjusting motor parameters if necessary.
- Lubrication of mechanical parts of the gate.
- Software updates if available.
Akiyesi: Always disconnect power to the control unit before performing any maintenance.
7. Laasigbotitusita
This section provides guidance for common issues. For complex problems, contact a qualified technician.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹnubode ko gbe. | No power supply; Safety device activated; Remote control battery low; Motor fault. | Check power connection and circuit breaker; Inspect safety devices for obstructions or misalignment; Replace remote control battery; Consult a technician for motor inspection. |
| Ẹnu-ọna duro lairotẹlẹ. | Obstacle detected; Safety device fault; Overload protection activated. | Remove any obstacles; Check and clean safety devices; Allow unit to cool down if overloaded, then reset. |
| Ẹnu-ọna ṣi ṣugbọn ko tii. | Safety device (e.g., photocell) obstructed or misaligned. | Check photocells for obstructions or dirt; Ensure they are correctly aligned. |
| Isakoṣo latọna jijin ko ṣiṣẹ. | Battery low/dead; Not programmed correctly; Interference. | Replace battery; Re-program remote control (refer to remote manual); Check for sources of interference. |
The LCU40H features a datalog via micro SD and dedicated software, allowing analysis of the chronology of the last alarms, significantly facilitating the identification of anomalies and maintenance.
8. Imọ ni pato
| Paramita | Iye |
|---|---|
| Awoṣe | LCU40H |
| Olupese | DITEC |
| Ibamu mọto | 1 or 2 motors, 24V DC |
| Max Motor Lọwọlọwọ | 2 x 12A o pọju |
| Ibi ti ina elekitiriki ti nwa | 230 VAC |
| Redio olugba | 433 MHz (pre-installed), switchable with 868 MHz module |
| Idaabobo ìyí | IP55 (plastic enclosure) |
| Awọn iwọn otutu ti nṣiṣẹ | -35°C to +55°C (with NIO function) |
| Awọn iwọn (H x W x D) | 357 x 238 x 120 mm |
| Ibamu Standard Abo | EN 13849 |
| Awọn iwe-ẹri | TUV RHEINLAND certified quality |
9. atilẹyin ọja Information
The DITEC LCU40H control unit comes with a 24-osu atilẹyin ọja from the date of purchase. This warranty covers manufacturing defects and faulty materials under normal use and service conditions.
Atilẹyin ọja naa ko ni aabo awọn bibajẹ ti o waye lati:
- Fifi sori ẹrọ tabi waya ti ko tọ.
- Awọn atunṣe tabi awọn atunṣe laigba aṣẹ.
- ilokulo, ilokulo, tabi aibikita.
- Acts of nature (e.g., lightning, floods).
- Ikuna lati tẹle awọn ilana inu iwe afọwọkọ yii.
For warranty claims, please contact your authorized DITEC dealer or installer with proof of purchase.
10. Atilẹyin ati Olubasọrọ
For technical assistance, spare parts, or professional servicing, please contact your authorized DITEC distributor or the professional installer who installed your system.
You can also visit the official DITEC webaaye fun awọn orisun afikun ati alaye olubasọrọ.
Akiyesi: As this is a professional product, direct end-user support may be limited. Always consult with your installer first.