1. Ifihan
The Victron Energy MultiPlus-II is a pure sine wave inverter charger that integrates the functionalities of both the MultiPlus and MultiGrid series. This unit is designed to provide reliable power conversion and battery charging for a wide range of applications, including marine, RV, off-grid, and industrial systems. It features an external current transformer option for advanced PowerControl and PowerAssist functionalities, optimizing self-consumption and ensuring stable power delivery.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your MultiPlus-II inverter charger.
2. Key Awọn ẹya ara ẹrọ
- Integrated Inverter and Charger: Combines a powerful pure sine wave inverter with an advanced battery charger.
- Iranlọwọ Agbara: Prevents overload of a limited AC source (e.g., generator or shore power) by boosting the output with power from the battery.
- Uninterrupted AC Power (UPS Function): In the event of a grid failure, the inverter automatically takes over the supply to connected loads within 20 milliseconds, ensuring continuous operation.
- Iṣẹ́ Ìpele-Ipele ati Ipele-Ipele-mẹta: Up to six units can operate in parallel for increased power output. Three units can be configured for three-phase output.
- Slimmer Profile: Modern manufacturing techniques result in a more compact design.
- Agbara Imurasilẹ Kekere: Designed for energy efficiency, consuming significantly less power in standby mode.
- Fifi sori Rọrun: Features accessible AC and DC connections via a service panel.
- Ibamu: Meets UPS and solar standards, including built-in anti-islanding.
3. Ọja Ipariview

olusin 3.1: Iwaju view of the Victron Energy MultiPlus-II Inverter Charger.

Olusin 3.2: Pariview of MultiPlus-II key features including MultiPlus/MultiGrid functions, external current transformer, PowerAssist, and remote monitoring.

Figure 3.3: Dimensions of the MultiPlus-II unit, highlighting its compact size.

Figure 3.4: Diagram illustrating the UPS function, showing how the MultiPlus-II provides uninterrupted AC power during grid outages.

Figure 3.5: The MultiPlus-II as a key component in an Energy Storage System (ESS), integrating with MPPT Solar Chargers or Grid-tie PV Inverters.
4. fifi sori
The MultiPlus-II is designed for wall mounting. A wall mount plate is included to facilitate installation.
4.1 odi iṣagbesori
- Securely mount the included wall mount plate to a suitable wall surface.
- Mú kíkì náà tò ní ẹ̀yìn MultiPlus-II casing with the wall mount plate and carefully hang the unit.
- Ensure the unit is firmly seated on the plate.
4.2 Awọn isopọ onirin
Before making any connections, ensure all power sources are disconnected. Always refer to the detailed wiring diagrams in the full product manual for specific instructions and safety guidelines.
- Unscrew the fasteners at the bottom of the enclosure and remove the service panel to access the connection terminals.
- Awọn isopọ batiri: Connect the battery cables to the designated terminals. Use a torque wrench with an insulated box spanner to tighten the connections to a maximum of 7 Nm to prevent short circuits.
- AC Mains and Load Connections: Connect the AC mains input and AC load outputs to their respective terminals. The MultiPlus-II features two AC outputs.
- Awọn isopọ ẹya ẹrọ: Connect any optional accessories such as a Venus GX, Color Control GX, or an external current transformer as required for your system.
- Once all connections are secure, reattach the service panel and fasten the screws.
Video 4.1: An introductory video to the Victron Energy MultiPlus-II, demonstrating its features and installation steps, including wall mounting and wiring connections.
5. Isẹ
5.1 Powering On/Off and Modes
The MultiPlus-II unit has a switch located at the bottom for controlling its operation modes:
- Position 'I' (On): The unit is fully operational, providing both inverter and charger functions.
- Position 'O' (Off): The unit is completely powered off.
- Position 'II' (Charger Only): The unit functions solely as a battery charger, without inverting AC power.
5.2 Àbójútó àti Ìṣàkóso
For comprehensive monitoring and control of your MultiPlus-II and the entire energy system, Victron Energy offers several accessories:
- Atẹle Batiri Ọlọ́gbọ́n BMV-712: Pese iwọn didun batiri akoko giditage, current, power, consumed Ah, and state of charge. Features built-in Bluetooth for monitoring via the VictronConnect app.
- Venus GX / Iṣakoso Awọ GX: These devices act as communication hubs, allowing for remote configuration and monitoring of your system when connected to the internet. Operational data can be stored and displayed on the free Victron Remote Management (VRM) webojula.
- Ohun elo VictronConnect: Connects to Bluetooth-enabled devices like the BMV-712 for instant access to system data on your smartphone or tablet.
- VRM Webojula: A free online portal for remote monitoring, configuration, and data analysis of your Victron Energy system from anywhere in the world.

Figure 5.1: Remote configuring and monitoring setup using a GX device connected to the internet.
6. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Orukọ awoṣe | PMP122305102 |
| Ọja Mefa | 6 x 11 x 23 inches |
| Iwọn Nkan | 55.4 iwon |
| Iṣagbewọle Voltage | 12 Volts |
| Orisun agbara | Agbara Batiri |
| Olupese | Agbara Victron |
| Ni akọkọ Wa | Oṣu kejila ọjọ 23, ọdun 2022 |
7. Laasigbotitusita
This section provides general guidance for common issues. For detailed troubleshooting, please refer to the comprehensive Victron Energy MultiPlus-II manual available on the official Victron Energy webojula tabi kan si atilẹyin alabara.
7.1 wọpọ oran
- Ko si AC Output: Check the input AC source, battery voltage, and the unit's operating mode (ensure it's not in 'Charger Only' mode). Verify all connections are secure.
- Batiri Ko Ngba agbara: Confirm AC input is present and stable. Check battery connections and the charger settings. Ensure the unit is in 'On' or 'Charger Only' mode.
- Ikilọ Apọju: Reduce the connected AC load. The PowerAssist feature should help prevent overloads, but excessive loads may still trigger a warning.
- Ẹka Ko Dahun: Power cycle the unit by switching it off and then back on. If the issue persists, check all wiring and consult the full manual.
8. Itọju
Ìtọ́jú déédéé ń rí i dájú pé agbára àti iṣẹ́ tó dára jùlọ ti ẹ̀rọ amúṣẹ́yọrí ẹ̀rọ amúṣẹ́yọrí MultiPlus-II rẹ.
- Ayẹwo igbagbogbo: Periodically inspect all wiring connections for tightness and signs of corrosion or damage.
- Ninu: Keep the unit's ventilation openings clear of dust and debris to ensure proper airflow and cooling. Use a soft, dry cloth for cleaning the exterior.
- Ilera Batiri: Monitor battery health regularly, especially if using lead-acid batteries. Ensure adequate ventilation during charging to prevent gas buildup.
- Awọn imudojuiwọn famuwia: Ṣayẹwo Lilo Victron website for available firmware updates to ensure your unit has the latest features and improvements.
9. Atilẹyin ọja ati Support
Victron Energy products are known for their quality and reliability. For warranty information, technical support, or service, please contact Victron Energy directly or an authorized dealer.
- Osise Webojula: Ṣabẹwo si Agbara Victron webojula for product documentation, FAQs, and support resources.
- Atilẹyin Onibara: Refer to your purchase documentation for specific contact details for customer support or your local dealer.