KAIWEETS KC602

KAIWEETS KC602 Smart Digital Clamp Afowoyi olumulo Mita

Model: KC602 | Brand: KAIWEETS

1. Ifihan

The KAIWEETS KC602 Smart Digital Clamp Meter is an advanced, auto-ranging multimeter designed for precise electrical measurements. Featuring D-shaped jaws, an HD color screen, and intelligent mode, it simplifies the process of measuring AC/DC current, voltage, resistance, continuity, capacitance, diode, NCV, firewire, and temperature. This manual provides essential information for safe and effective operation of your device.

2. Alaye Aabo

Always adhere to safety precautions when operating electrical testing equipment. This device complies with safety standard IEC 61010-1, CAT IV 600V. Failure to follow these guidelines may result in electric shock, fire, or damage to the meter or the equipment under test.

  • Má ṣe lo mita náà bí ó bá hàn pé ó ti bàjẹ́ tàbí tí àwọn èdìdì ìdánwò náà bá ti bàjẹ́.
  • Rí i dájú pé a yan iṣẹ́ àti ìwọ̀n tó yẹ kí a tó ṣe àwọn ìwọ̀n.
  • Maṣe kọja awọn iye titẹ sii ti o pọju fun iṣẹ eyikeyi.
  • Ṣọra pupọ nigbati o ba n ṣiṣẹ pẹlu voltages loke 30V AC RMS, 42V tente oke, tabi 60V DC. Awọn wọnyi ni voltages duro a mọnamọna ewu.
  • Always disconnect power to the circuit before measuring resistance, continuity, capacitance, or diode.
  • Jeki awọn ika ọwọ lẹhin awọn oluso ika lori awọn itọsọna idanwo lakoko lilo.
  • Rọpo awọn batiri ni kiakia nigbati atọka batiri kekere ba han.

3. Package Awọn akoonu

Daju pe gbogbo awọn nkan wa ati pe ko bajẹ lori ṣiṣi package naa:

  • KAIWEETS KC602 Clamp Mita
  • Awọn batiri 3 x AAA (ti fi sii tẹlẹ tabi pẹlu lọtọ)
  • Àwọn Ìdánwò (pupa kan, dúdú kan)
  • Thermocouple
  • Itọsọna olumulo
  • Ọran gbigbe
KAIWEETS KC602 Clamp Mita ati awọn ẹya ẹrọ

Figure 3.1: KAIWEETS KC602 Clamp Meter with included test leads, batteries, thermocouple, and carrying case.

4. Awọn ẹya Ọja

  • Upgraded Intelligent Mode: Ṣe idanimọ vol AC/DC laifọwọyitage/current, resistance, and continuity measurement signals for convenient and safe operation.
  • Advanced Design & Multi-function: Includes MAX/MIN, data hold, flashlight, and auto-off features. D-shaped jaws are designed to hold test leads and enhance portability. Measures AC/DC current/voltage, resistance, continuity, capacitance, diode, NCV, firewire, and temperature.
  • Large HD Color Screen: Provides clear readability, even in dark environments, and reduces difficulty reading under direct sunlight.
  • Self-test & Inrush Measurement Function: Performs an automatic self-test ("CAL" display) upon power-on to ensure measurement accuracy. Inrush current measurement (5-600A) is available in AC current mode to help diagnose startup problems.
  • Ibamu Aabo: Meets IEC 61010-1, CAT IV 600V safety standards.
KAIWEETS KC602 Multi-function display

Olusin 4.1: Pariview of the multi-functional capabilities of the KC602 meter, showing various measurement icons.

KAIWEETS KC602 Smart Mode and HD Color Screen

Figure 4.2: The KC602's smart mode and high-definition color screen for improved readability.

5. Eto

5.1 Fifi sori batiri

The KAIWEETS KC602 requires 3 AAA batteries (included). To install or replace batteries:

  1. Rii daju pe mita naa ti wa ni pipa.
  2. Wa ideri ibi ipamọ batiri naa ni ẹhin mita naa.
  3. Lo screwdriver lati ṣii yara batiri naa.
  4. Insert the 3 AAA batteries, observing the correct polarity (+ and -).
  5. Rọpo ideri kompaktimenti batiri ki o ni aabo pẹlu dabaru.

5.2 Nsopọ Awọn itọsọna Igbeyewo

Fún ọ̀pọ̀lọpọ̀ ìwọ̀n (ìwọ̀n)tage, resistance, continuity, capacitance, diode, temperature), the test leads are required.

  1. Insert the red test lead into the "VΩmA" input jack.
  2. Insert the black test lead into the "COM" input jack.
  3. Ensure the connections are secure before proceeding with measurements.

6. Awọn ilana Iṣiṣẹ

Tẹ bọtini agbara () to turn on the meter. The meter will perform a self-test and display "CAL" before entering Smart Mode.

6.1 Smart Mode (Auto-recognition)

In Smart Mode, the meter automatically identifies the type of measurement (AC/DC voltage/current, resistance, continuity) and selects the appropriate range. This simplifies operation for common tasks.

KAIWEETS KC602 Smart Mode display

Figure 6.1: The meter operating in Smart Mode, automatically detecting the measurement type.

6.2 Function Selection (Manual Mode)

Tẹ awọn FUNC button to cycle through different measurement functions (e.g., Voltage, Resistance, Capacitance, Diode, Temperature, NCV, Inrush Current). The selected function will be indicated on the display.

6.3 AC / DC Voltage Idanwo

  1. Connect the red test lead to the "VΩmA" jack and the black test lead to the "COM" jack.
  2. Yan voltage measurement function (V~ for AC, V- for DC) using the FUNC button if not in Smart Mode.
  3. Apply the test probes across the circuit or component to be measured.
  4. Ka voltage iye lori ifihan.
KAIWEETS KC602 AC/DC Voltage Idanwo

Figure 6.2: Performing an AC/DC voltage test using the test leads.

6.4 AC/DC Current Test (Clamp Measurement)

For current measurement, use the clamp ẹrẹkẹ. Do not use test leads for current measurement with the clamp.

  1. Select the current measurement function (A~ for AC, A- for DC) using the FUNC button if not in Smart Mode.
  2. Ṣii clamp jaws and enclose only one conductor (wire) of the circuit. Ensure the jaws are fully closed.
  3. Ka iye lọwọlọwọ lori ifihan naa.
KAIWEETS KC602 AC/DC Current Test

Figure 6.3: Measuring AC/DC current by clamping ni ayika kan nikan adaorin.

6.5 Idanwo lọwọlọwọ Inrush

The inrush current function measures the initial surge of current when a device is powered on. This function is only available in AC current mode and has a measurement range of 5-600A.

  1. Select the AC current function.
  2. Tẹ awọn FỌRỌ button (if available, or cycle through FUNC until Inrush is selected).
  3. Ṣii clamp jaws and enclose the conductor.
  4. Power on the device to measure the inrush current.
KAIWEETS KC602 Inrush Current Test

Figure 6.4: Measuring the inrush current of an electrical component.

6.6 Non-olubasọrọ Voltage (NCV) Idanwo

Iṣẹ́ NCV ń ṣàwárí wíwà AC voltage without physical contact with the conductor.

  1. Select the NCV function using the FUNC bọtini.
  2. Place the top of the meter (where the NCV sensor is located) near the conductor or outlet.
  3. The meter will indicate the presence of voltage through audible beeps and visual indicators on the display.
KAIWEETS KC602 Non-Contact Voltage Idanwo

Àwòrán 6.5: Lílo iṣẹ́ NCV láti ṣàwárí voltage lai taara olubasọrọ.

6.7 Resistance, Continuity, Capacitance, Diode Test

For these functions, ensure the circuit is de-energized before connecting the test leads.

  • Agbára ìdènà (Ω): Connect test leads across the component.
  • Itesiwaju (🔊): Connect test leads across the circuit. A continuous beep indicates continuity.
  • Agbara (): Connect test leads across the capacitor (ensure it's discharged).
  • Diode (▶|): So awọn itọsọna idanwo kọja diode naa.

6.8 Wiwọn iwọn otutu

Use the included thermocouple for temperature measurements.

  1. Connect the thermocouple to the appropriate input jacks (usually VΩmA and COM, check meter markings).
  2. Select the temperature function (°C/°F) using the FUNC bọtini.
  3. Place the thermocouple tip on the object or in the environment to be measured.
  4. Ka iwọn otutu lori ifihan.

6.9 Afikun Awọn iṣẹ

  • O pọju/MIN: Tẹ awọn MAX/MIN button to record the maximum and minimum readings during a measurement session.
  • Idaduro data: Tẹ awọn DIMU bọ́tìnì láti dì kíkà tó wà lórí ìbòjú náà. Tẹ̀ lẹ́ẹ̀kan síi láti tú u sílẹ̀.
  • Imọlẹ ina: The meter includes a built-in flashlight for illuminating dimly lit work areas. Activate it via a dedicated button or a long press of a function button (refer to meter markings).
  • Pa a Aifọwọyi: The meter automatically powers off after approximately 15 minutes of inactivity to conserve battery life. This feature can typically be disabled by holding a specific button during power-on (refer to meter markings for details).
KAIWEETS KC602 in dimly lit environment

Figure 6.6: The KC602's bright display and integrated flashlight for use in low-light conditions.

7. Itọju

  • Ninu: Nu mita naa casing pẹlu ipolowoamp asọ ati ìwọnba detergent. Maṣe lo awọn abrasives tabi awọn nkan ti a nfo.
  • Rirọpo Batiri: Replace batteries when the low battery indicator appears on the display. Refer to Section 5.1 for instructions.
  • Ibi ipamọ: Tí a kò bá lo mita náà fún ìgbà pípẹ́, yọ àwọn batiri náà kúrò kí ó má ​​baà jẹ́ kí omi máa jò. Tọ́jú mita náà sí ibi tí ó tutù, tí ó gbẹ, tí kò sí ìmọ́lẹ̀ oòrùn tààrà àti ooru tó le koko.
  • Awọn itọsọna Idanwo: Inspect test leads for any damage (cuts, cracks) before each use. Replace if damaged.

8. Laasigbotitusita

IsoroOwun to le FaOjutu
Mita ko ni agbara lori.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Ṣayẹwo polarity batiri tabi ropo awọn batiri.
Awọn kika ti ko pe.Incorrect function selected; test leads not fully inserted; meter not calibrated (though self-calibrating); external interference.Ensure correct function. Re-insert test leads. Power cycle the meter. Avoid strong electromagnetic fields.
Display is dim or hard to read.Low battery; direct sunlight; screen protector.Replace batteries. Move to a shaded area. Remove any temporary screen protectors.
Ko si ohun orin ilosiwaju.Circuit is open; incorrect function; low battery.Verify circuit continuity. Ensure continuity function is selected. Replace batteries.
"OL" or "OVER" displayed.Wíwọ̀n náà ju ibi tí a yàn tàbí agbára tí ó pọ̀ jùlọ ti àwọn mítà lọ.Switch to a higher range if available, or note that the value is out of range.

9. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeKC602
BrandKAIWEETS
Orisun agbaraAgbara Batiri (Batiri AAA 3 to wa)
Aabo StandardIEC 61010-1, CAT IV 600V
IfihanHD Color Screen, 6000 Counts
AC Lọwọlọwọ RangeUp to 600A (with Inrush function 5-600A)
DC Lọwọlọwọ RangeTiti di 600A
Voltage IbitiAC/DC Voltage titi di 600V
Resistance RangeBẹẹni
Agbara RangeBẹẹni
Iwọn Iwọn otutuYes (with thermocouple)
NCV (Non-Kan si Voltage)Bẹẹni
Idojukọ AifọwọyiYes (approx. 15 minutes)
Iwọn Nkan240 giramu
Package Mefa8.9 x 4.65 x 2.05 inches

10. Atilẹyin ọja ati Support

KAIWEETS offers a 3-year after-sales service and lifetime technical assistance for the KC602 Smart Digital Clamp Meter. For any questions, technical support, or warranty claims, please contact KAIWEETS customer service through their official channels or the retailer where the product was purchased.

For more information, visit the official KAIWEETS Store: KAIWEETS Store on Amazon

Awọn iwe aṣẹ ti o jọmọ - KC602

Ṣaajuview KAIWEETS HT208D True-RMS Digital Clamp Afowoyi olumulo Mita
Ìwé ìtọ́ni tó péye fún KAIWEETS HT208D True-RMS Digital Clamp Mita. Kọ́ nípa àwọn ẹ̀yà ara rẹ̀, ìwífún nípa ààbò, àwọn ìtọ́ni ìṣiṣẹ́, àti àwọn ìlànà pàtó fún wíwọ̀n ìṣàn omi AC/DC, vol.tage, ìgbagbogbo, resistance, capacitance, ati iwọn otutu.
Ṣaajuview KAIWEETS HT206D Digital Clamp Itọsọna olumulo Mita ati Awọn pato
Okeerẹ afọwọṣe olumulo fun KAIWEETS HT206D oni clamp mita. Pẹlu awọn itọnisọna alaye lori iṣẹ, awọn iṣọra ailewu, awọn ẹya, awọn pato, ati itọju fun T-RMS AC/DC laifọwọyiamp mita.
Ṣaajuview KAIWEETS HT206D True-RMS Digital Clamp Afowoyi olumulo Mita
Ìwé ìtọ́ni tó péye fún KAIWEETS HT206D True-RMS Digital Clamp Mita. Kọ́ nípa àwọn ẹ̀yà ara rẹ̀, ìwífún nípa ààbò, àwọn ìtọ́ni ìṣiṣẹ́, àti àwọn ìlànà pàtó fún àwọn ìwọ̀n iná mànàmáná tó péye.
Ṣaajuview KAIWEETS HT206B True-RMS Digital Clamp Afowoyi olumulo Mita
Ìwé ìtọ́ni tó péye fún KAIWEETS HT206B True-RMS Digital Clamp Mita, ti o ṣe alaye awọn ẹya ara ẹrọ rẹ, alaye aabo, awọn itọnisọna iṣiṣẹ, ati awọn pato fun awọn wiwọn ina oriṣiriṣi.
Ṣaajuview KAIWEETS KC602 True-RMS Smart Clamp Afowoyi olumulo Mita
User manual for the KAIWEETS KC602 True-RMS Smart Clamp Meter, detailing its features, safe operation, and electrical measurement capabilities, including inrush current capture.
Ṣaajuview KAIWEETS HT118A Digital Multimeter User Afowoyi
Itọnisọna olumulo pipe fun KAIWEETS HT118A Digital Multimeter, awọn ilana aabo ti o bo, apejuwe ọja, awọn ẹya multimeter, awọn iṣẹ wiwọn, ati awọn pato.