1. Ifihan
The TOPENS CK2500 Automatic Sliding Gate Opener is designed for heavy-duty sliding gates, providing a secure and convenient access solution. This chain-driven electric gate motor is capable of operating gates up to 5700 pounds in weight and 40 feet in length. It features a 1-1/4 HP 1000W AC motor, ensuring reliable and quiet performance for residential, commercial, courtyard, farm, and ranch applications. This manual provides detailed instructions for installation, operation, maintenance, and troubleshooting to ensure safe and efficient use of your gate opener.

Figure 1.1: The TOPENS CK2500 Automatic Sliding Gate Opener in use, demonstrating its application for property access.
2. Alaye Aabo pataki
Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in serious injury or property damage. Keep this manual for future reference.
- Rii daju pe gbogbo awọn asopọ itanna ni ibamu pẹlu awọn koodu agbegbe ati ilana.
- Disconnect power to the gate opener before performing any maintenance or repairs.
- Keep children and pets away from the gate area, especially during operation.
- Ma ṣe gba awọn ọmọde laaye lati ṣiṣẹ ṣiṣi ẹnu-ọna tabi ṣere pẹlu awọn isakoṣo latọna jijin.
- Install the gate opener on a structurally sound gate and post system.
- Ensure the gate moves freely and smoothly before installing the opener.
- Use the provided photo eye sensor to prevent the gate from closing on obstructions.
- In case of power failure, use the manual release key to operate the gate manually.
- Do not attempt to repair the gate opener yourself. Contact qualified personnel for service.
3. Package Awọn akoonu
Verify that all items listed below are included in your package. If any parts are missing or damaged, please contact TOPENS customer support.

Figure 3.1: Main components included with the TOPENS CK2500 Automatic Sliding Gate Opener.
- Sliding Gate Opener Unit (CK2500)
- 20ft Roller Chain
- Awọn iṣakoso latọna jijin meji
- TC102 Photo Eye Beam Sensor (Pair)
- Awọn bọtini itusilẹ Afowoyi
- Magnet Assembly (Limit Switches)
- Mounting Hardware (Bolts, Nuts, Washers)
- Ilana itọnisọna
4. Itọsọna fifi sori ẹrọ
This section provides step-by-step instructions for installing your TOPENS CK2500 gate opener. It is recommended to have basic mechanical and electrical knowledge for this installation. No welding is required.
4.1. Mounting the Operator
The gate opener should be mounted on a stable, level concrete pad or a sturdy post adjacent to the gate. Ensure sufficient clearance for the gate's movement and the chain installation.
- Determine the optimal mounting position, ensuring the drive sprocket aligns with the gate's chain path.
- Securely fasten the gate opener unit to the mounting surface using appropriate bolts and anchors.
- Verify the unit is level and stable.

Figure 4.1: Dimensions of the CK2500 unit and a general installation diagram including optional accessories like the photo eye and external receiver.
4.2. Installing the Drive Chain
The 20ft roller chain connects the gate to the opener's drive sprocket, facilitating movement.
- Attach one end of the chain securely to the gate.
- Route the chain around the drive sprocket of the opener.
- Attach the other end of the chain to the gate, ensuring proper tension. The chain should be taut but not overly tight.
- Adjust the chain length as needed to fit your gate.

Figure 4.2: Illustration of the robust chain drive system.
4.3. Itanna onirin
The CK2500 operates on 110-120VAC electricity ONLY. Ensure power is OFF before making any connections.
- Connect the AC power supply to the designated terminals inside the control box.
- Ensure all wiring is secure and properly insulated.
- Refer to the wiring diagram provided in the full manual for specific connections.

Figure 4.3: Power connection for the 110-120VAC system.
4.4. Adjusting Limit Switches
The electromagnetism limit switches define the gate's open and closed positions.
- Mount the magnet assembly to the gate at the desired open and closed positions.
- Ensure the magnets are correctly oriented to trigger the internal sensors.
- Test the gate's movement and adjust magnet positions for precise stopping points.

Figure 4.4: Magnet assembly for setting gate limits.
4.5. Installing Photo Eye Sensor (TC102)
The TC102 Photo Eye Beam Sensor is a crucial safety feature that reverses the gate if an obstruction is detected during closing.
- Mount the transmitter and receiver units of the photo eye sensor on opposite sides of the gate opening, ensuring they are aligned.
- Connect the photo eye sensor wiring to the control board as per the detailed wiring diagram.
- Test the sensor by breaking the beam during gate closing to ensure it reverses.

Figure 4.5: TC102 Photo Eye Beam Sensor and remote control.
5. Isẹ
This section details how to operate your TOPENS CK2500 Automatic Sliding Gate Opener.
5.1. Sisopọ Iṣakoso latọna jijin
To operate the gate opener with a remote control, it must first be paired with the system. Refer to the full manual for specific pairing instructions for your remote model.
5.2. Basic Gate Operation
Pressing the paired remote button will initiate the gate's movement. A single press will open or close the gate. Pressing again during movement will stop the gate.

Olusin 5.1: Pariview of key operational features including self-closing, midway mode, and safety mechanisms.
5.3. Midway Mode
The "midway mode" allows for partial gate opening, useful for pedestrian access or when only a small opening is required for vehicles.
- Activate midway mode via a specific remote button or setting (refer to full manual).
- The gate will open to a pre-set partial position.

Figure 5.2: Visual representation of self-closing, midway mode, and obstruction reversal.
5.4. Auto-Close Function
The "auto-close" function automatically closes the gate after a set period, enhancing property security.
- This feature can be enabled and configured for a specific delay time through the control board settings.
- Ensure the photo eye sensor is correctly installed and functioning when using auto-close.
5.5. Afọwọṣe Tu
Ni ọran ti agbara otages or remote control loss, the gate can be operated manually using the provided release key.
- Insert the manual release key into the lock cylinder on the opener unit.
- Turn the key to disengage the motor, allowing the gate to be pushed open or closed by hand.
- Remember to re-engage the motor after manual operation for automatic functionality.

Figure 5.3: Manual release key for operating the gate during power outages.
6. Itọju
Regular maintenance ensures the longevity and optimal performance of your TOPENS CK2500 gate opener.
- Oṣooṣu: Inspect the gate's movement for any obstructions or friction. Ensure the gate wheels and hinges are clean and lubricated.
- Ni idamẹrin: Check the drive chain tension and lubricate it if necessary. Inspect all electrical connections for corrosion or looseness.
- Ọdọọdún: Test the photo eye sensor and other safety features to ensure they are functioning correctly. Clean the exterior of the opener unit.
- Keep the area around the gate opener clear of debris, snow, or ice.

Figure 6.1: The gate opener features a waterproof design for outdoor use, but regular cleaning is still recommended.
7. Laasigbotitusita
This section addresses common issues you might encounter with your gate opener. For more complex problems, refer to the full user manual or contact customer support.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹnu-ọna ko dahun si latọna jijin. | Dead remote battery, remote not paired, power outage. | Replace remote battery, re-pair remote, check power supply. |
| Ẹnu-ọna duro tabi yiyipada lairotẹlẹ. | Obstruction detected by photo eye, limit switch issue, excessive friction. | Clear obstruction, check photo eye alignment, inspect gate path, adjust limit switches. |
| Motor nṣiṣẹ sugbon ẹnu-bode ko ni gbe. | Chain disengaged or broken, manual release engaged. | Check chain connection and tension, disengage manual release. |
| Ẹnubodè ṣí díẹ̀. | Midway mode activated, limit switch misadjusted. | Deactivate midway mode, re-adjust open limit switch. |
8. Awọn pato
Technical specifications for the TOPENS CK2500 Automatic Sliding Gate Opener.
- Awoṣe: CK2500
- O pọju. Ìwọ̀n Ẹnubodè: 5700 lbs
- O pọju. Gigun ẹnu-ọna: 40 ft
- Agbara mọto: 1-1/4 HP (1000W) AC Motor
- Ibi ti ina elekitiriki ti nwa: 110-120VAC
- Ipo Wakọ: Chain Drive (20ft chain included)
- Iwọn Iṣiṣẹ: 0°F de 120°F
- Ìwọ̀n Nkan: 55.9 iwon
- Awọn iwọn ọja: 10.7 x 5.9 x 19.7 inches
- Batteries (for remotes): Awọn batiri 6 CR2 nilo (pẹlu)
- Awọn ẹya Aabo: Photo Eye Beam Sensor, Auto-Close, Midway Mode, Manual Release Key
9. Atilẹyin ọja ati Onibara Support
TOPENS products come with a 12-month warranty against defects and a 30-day exchange & return policy. For technical assistance, user manuals, installation videos, or personalized service, please visit the official TOPENS webojula tabi kan si wọn atilẹyin alabara egbe.
Ibi iwifunni:
- Webojula: www.topens.com (Eksample link, actual link not provided in JSON, so using a generic one)
- Imeeli: Refer to TOPENS webojú-òpó wẹ́ẹ̀bù fún ìfiranṣẹ́ ìrànlọ́wọ́.
- Foonu: Refer to TOPENS webaaye fun nọmba foonu atilẹyin.

Figure 9.1: TOPENS offers professional customer support for all inquiries.