This manual provides essential information for the safe and efficient operation, installation, and maintenance of your IMMERGAS VICTRIX TERA 24 V2 KW MET wall-mounted condensing boiler. Please read this manual thoroughly before installation or use and keep it for future reference. This boiler is designed for heating and instantaneous domestic hot water production, powered by methane gas.

IMMERGAS VICTRIX TERA 24 V2 KW MET Wall-Mounted Condensing Boiler

Iwaju view of the IMMERGAS VICTRIX TERA 24 V2 KW MET wall-mounted condensing boiler, showing its white casing and the integrated digital control panel with buttons and a pressure gauge at the bottom right.

2. Alaye Aabo pataki

Always adhere to local regulations and safety standards during installation, operation, and maintenance. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for assistance.

  • Aabo Gaasi: Ensure proper ventilation. In case of a gas leak, do not operate electrical switches, extinguish all open flames, and immediately contact your gas supplier.
  • Aabo Itanna: Disconnect power before servicing. Ensure the boiler is properly grounded.
  • Aabo omi: The boiler operates with water. Be aware of hot surfaces and hot water.
  • Ààbò fún dídì: The boiler includes standard antifreeze protection down to -5 °C. For lower temperatures, additional measures may be required.

3. Eto ati fifi sori

The IMMERGAS VICTRIX TERA 24 V2 KW MET boiler is designed for wall-mounted installation. It is approved for operation indoors and outdoors in partially protected locations. Installation must be performed by a qualified and certified technician in accordance with all applicable local and national codes.

3.1 Unpacking ati ayewo

Carefully unpack the boiler and inspect it for any shipping damage. Ensure all components, including the connection kit, are present.

3.2 Mounting the Boiler

Select a suitable wall location that can support the boiler's weight (approximately 31.2 kg). Ensure adequate clearance for maintenance and ventilation. Use appropriate mounting hardware for secure installation.

3.3 Awọn isopọ

Connect the gas supply, water inlet/outlet, and electrical supply according to the provided diagrams and local regulations. Ensure all connections are leak-free and secure. The boiler requires a natural gas supply.

3.4 Initial Fill and Purge

After all connections are made, fill the heating system with water and carefully purge all air from the system. Check the system pressure on the boiler's display or pressure gauge.

4. Awọn ilana Iṣiṣẹ

The VICTRIX TERA 24 V2 KW MET boiler features an intuitive digital control panel for easy operation.

4.1 Titan / Pa a

To power on the boiler, ensure the main electrical switch is in the 'ON' position. The display will illuminate. To power off, switch the main electrical switch to 'OFF'.

4.2 Eto otutu

Use the '+' and '-' buttons on the control panel to adjust the desired heating and domestic hot water temperatures. The current settings will be shown on the digital display.

4.3 Awọn ọna ṣiṣe

The boiler typically operates in heating mode, domestic hot water mode, or a combination. Refer to the specific icons on the control panel for mode selection and status indicators.

4.4 Pressure Monitoring

Regularly check the system pressure on the integrated pressure gauge. The optimal operating pressure is typically between 1.0 and 1.5 bar. If the pressure drops too low, repressurize the system as per installation guidelines.

5. Itọju

Regular maintenance is crucial for the longevity and efficient operation of your IMMERGAS boiler. It is recommended to have the boiler inspected and serviced annually by an authorized Immergas service center.

5.1 Annual Servicing

An authorized technician will perform checks on combustion efficiency, gas connections, water pressure, safety devices, and clean internal components to ensure optimal performance and safety.

5.2 User Checks

  • Ayewo wiwo: Periodically check for any visible leaks or unusual noises.
  • Ṣayẹwo titẹ: Monitor the system pressure and top up if necessary.
  • Afẹfẹ: Ensure that the area around the boiler is clear and ventilation openings are not obstructed.

The 'Comfort 10' program offers a comprehensive maintenance plan for 10 years, extendable up to 15 years, without activation costs. This program can be activated during the initial verification in collaboration with an authorized Immergas assistance center.

6. Laasigbotitusita

This section provides solutions for common issues you might encounter. For problems not listed here or if solutions do not resolve the issue, contact an authorized service technician.

IsoroOwun to le FaOjutu
Ko si igbona tabi omi gbonaItẹ agbara eto kekere, ko si ipese gaasi, agbara outage, boiler lockoutCheck pressure and repressurize if needed. Verify gas supply. Check power. Reset boiler if in lockout (refer to display error codes).
Bọ́ílì tó ń ṣe àwọn ariwo tó yàtọ̀Air in system, pump issue, limescale buildupBleed radiators. Contact service technician for pump or limescale issues.
Aṣiṣe koodu lori ifihanSpecific fault detected by boiler's self-diagnosticsNote the error code and consult the detailed error code list in the full technical manual or contact an authorized service technician, providing the code.
Omi joLoose connection, faulty component, excessive pressureTurn off water supply to boiler. Contact a qualified technician immediately.

7. Imọ ni pato

Ẹya ara ẹrọSipesifikesonu
AwoṣeVICTRIX TERA 24 V2 KW MET
OlupeseImmergas
Awọn iwọn Ọja (L x W x H)26 x 44 x 75 cm
Iwọn31.2 kilo
Àwọ̀Funfun
Orisun agbaraGaasi Adayeba
Pataki ẸyaAntifreeze Protection (down to -5 °C)
Awọn irinše to waBoiler, Connection Kit
Iṣagbesori IruÒgiri Ògiri
Ṣiṣe RatingA (Energy Efficiency)
Ecological ClassClass 6 (UNI EN 15502) for NOX emissions
Itanna IdaaboboIPX5D

8. atilẹyin ọja Information

IMMERGAS offers a comprehensive 'Comfort 10' program for this boiler, providing a maintenance and warranty period of 10 years, with the possibility to extend it up to 15 years. This program does not incur activation costs and can be initiated during the initial verification of the boiler by an authorized Immergas assistance center. For detailed terms and conditions of the warranty, please refer to the documentation provided with your boiler or contact an authorized Immergas service partner.

9. Onibara Support

For technical assistance, spare parts, or to schedule service, please contact your local authorized IMMERGAS service center or the dealer from whom you purchased the product. Always provide the full model number (3.032927) and serial number of your boiler when seeking support.

You can find contact information for authorized service centers on the official Immergas webojú-òpó wẹ́ẹ̀bù tàbí nípasẹ̀ ìwé àṣẹ ọjà rẹ.

Awọn iwe aṣẹ ti o jọmọ - 3.032927

Ṣaajuview Immergas VICTRIX PRO V2 EU: Apoti Imọ-ẹrọ Ipilẹ Agbara giga
Iwe imọ-ẹrọ pipe fun Immergas VICTRIX PRO V2 EU jara ti agbara giga, awọn igbomikana condensing ti ogiri. Awọn alaye ni pato, awọn ẹya ara ẹrọ, awọn awoṣe (35-180 EU), awọn aṣayan fifi sori ẹrọ, awọn ẹya ẹrọ, ati data imọ-ẹrọ fun awọn solusan alapapo daradara.
Ṣaajuview Immergas VICTRIX PRO V2 EU: Apoti Imọ-ẹrọ Ipilẹ Agbara giga
Ṣawari iwọn Immergas VICTRIX PRO V2 EU ti agbara giga, awọn igbomikana condensing ti ogiri. Ṣe afẹri awọn ẹya ilọsiwaju, awọn alaye imọ-ẹrọ, irọrun fifi sori ẹrọ, ati awọn anfani ayika fun awọn solusan alapapo daradara.
Ṣaajuview Afowoyi de Utilizare Immergas Victrix Tera 28 1 - 32 1
Acest manual de utilizare pentru centrala termică în condensare Immergas Victrix Tera (modele 28 1 ati 32 1) lati fi sori ẹrọ ni pipe pipe, operare ati awọn ilana. Pẹlu recomandări tehnice, instrucțiuni de siguranță și información despre accesorii, asigurân and performanceanța optimă a paratului.
Ṣaajuview Immergas VICTRIX PRO 2 ErP: Awọn igbomikana Imudara Agbara-giga - Awọn pato Imọ-ẹrọ
Awọn alaye imọ-ẹrọ alaye fun Immergas VICTRIX PRO 2 ErP ibiti o ni agbara giga, awọn igbomikana condensing ti ogiri. Awọn awoṣe bo VICTRIX PRO 35-55 2 ErP ati VICTRIX PRO 80-100-120 2 ErP, awọn iwọn apejuwe, awọn ẹya, data imọ-ẹrọ, ati awọn ẹya ẹrọ fifi sori ẹrọ fun awọn solusan alapapo daradara.
Ṣaajuview Immergas VICTRIX PRO 1 I Series: Awọn igbomikana ti o ni agbara giga - Imọ-ẹrọview
Ṣe afẹri Immergas VICTRIX PRO 1 I jara ti awọn igbomikana alapapo apọjuwọn ti a fi ogiri ṣe, ti a ṣe fun alapapo agbara giga. Iwe-ipamọ imọ-ẹrọ yii ṣe alaye awọn pato, awọn ẹya, ati awọn aṣayan fifi sori ẹrọ fun ibugbe nla, iṣowo, ati awọn ohun elo ile-iṣẹ, tẹnumọ ṣiṣe ati iṣẹ ṣiṣe ayika.
Ṣaajuview Immergas VICTRIX PRO 2 ErP Series: Imọ ni pato ati Afowoyi
Iwe imọ-ẹrọ pipe fun Immergas VICTRIX PRO 2 ErP awọn igbomikana condensing ogiri, awọn alaye alaye, awọn iwọn, awọn ẹya, awọn aṣayan fifi sori ẹrọ, ati data iṣẹ fun awọn awoṣe bii VICTRIX PRO 35-55 ati 80-100-120.