Laserliner 080.967A

Laserliner MultiScanner Plus 080.967A Instruction Manual

Awoṣe: 080.967A

1. Ifihan

Thank you for choosing the Laserliner MultiScanner Plus 080.967A. This advanced wall scanner is designed to accurately detect various materials hidden behind walls, ceilings, and floors, including wood studs, metal objects (ferrous and non-ferrous), and live AC electrical wires. Please read this manual thoroughly before operation to ensure safe and effective use of the device.

2. Ọja Ipariview

The MultiScanner Plus 080.967A features a clear display, intuitive controls, and multiple scanning modes for comprehensive detection. Its ergonomic design ensures comfortable handling during use.

Laserliner MultiScanner Plus 080.967A device

olusin 2.1: Iwaju view of the Laserliner MultiScanner Plus 080.967A.

Laserliner MultiScanner Plus 080.967A with packaging and USB-C cable

Figure 2.2: MultiScanner Plus 080.967A with its packaging and included USB-C charging cable, highlighting the built-in Li-Ion battery.

Awọn ẹya pataki:

3. Awọn ilana aabo

Nigbagbogbo ṣe akiyesi awọn iṣọra ailewu atẹle lati yago fun ipalara tabi ibajẹ si ẹrọ naa:

4. Eto

4.1 Ngba agbara si Batiri naa

The MultiScanner Plus is equipped with a built-in rechargeable Li-Ion battery. Before first use, fully charge the device.

  1. Connect the included USB-C cable to the charging port on the device.
  2. Connect the other end of the USB-C cable to a standard USB power adapter (not included) or a computer USB port.
  3. The charging indicator on the device will show the charging status. Once fully charged, disconnect the cable.
Laserliner MultiScanner Plus 080.967A USB-C charging port

olusin 4.1: Isunmọ view of the USB-C charging port and the "RE-CHARGE" indicator.

4.2 Iṣatunṣe Ibẹrẹ

For accurate results, the device requires calibration before each scan or when changing scanning modes. Perform calibration on a clear section of the wall, free from any known objects.

  1. Tẹ awọn Agbara bọtini lati tan ẹrọ naa.
  2. Place the device flat against the wall where you intend to scan.
  3. Tẹ mọlẹ CAL button until the calibration process is complete (indicated on the display).
  4. Move the device slowly across the surface during calibration as instructed on the screen.
Laserliner MultiScanner Plus 080.967A calibration screen

Figure 4.2: The device display showing calibration instructions: "MOVE", "PRESS CAL", "CAL OK".

5. Awọn ilana Iṣiṣẹ

5.1 Selecting a Mode

Tẹ awọn Ipo button to cycle through the available scanning modes: Stud Scan, Metal Scan, and AC Scan.

5.2 Scanning Procedure

Once a mode is selected and the device is calibrated, slowly move the scanner across the surface. The display will provide visual feedback, and an audible signal may indicate detection.

Laserliner MultiScanner Plus 080.967A display showing detection

Figure 5.1: The device display indicating a detected object, with visual bars showing signal strength and location.

5.3 Detection Modes and Depths

Laserliner MultiScanner Plus 080.967A detection depth chart

Figure 5.2: Illustration of typical detection depths for Stud Scan, AC Scan, and Metal Scan modes.

5.4 Live Wire Warning

The device will display a specific warning icon and/or emit an audible alert when live AC wires are detected, regardless of the selected mode. Always exercise extreme caution when this warning appears.

Laserliner MultiScanner Plus 080.967A live AC wire warning

Figure 5.3: The device display showing the live AC wire warning symbol (AC 230V) and detection bars.

5.5 Practical Application Examples

Laserliner MultiScanner Plus 080.967A detecting rebar in a wall

Olusin 5.4: Example of using the MultiScanner Plus to detect rebar or pipes within a concrete wall before drilling.

Laserliner MultiScanner Plus 080.967A detecting a stud

Olusin 5.5: Example of using the MultiScanner Plus to locate a wooden stud behind drywall for secure mounting.

Laserliner MultiScanner Plus 080.967A display showing detection

Figure 5.6: The device display showing a strong signal indicating a detected object, with the "STUD" and "CENTER" indicators.

6. Itọju

6.1 Ninu

Nu ẹrọ naa pẹlu asọ, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is dry before storage.

6.2 Ibi ipamọ

Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Inaccurate readings / False positivesImproper calibration; high humidity; presence of dense materials.Recalibrate the device on a clear section of the wall. Ensure the scanning surface is dry.
Ẹrọ ko ni tan-anBatiri ti dinku.Gba agbara si ẹrọ naa nipa lilo okun USB-C.
No detection in a specific modeIncorrect mode selected; object is too deep or too small.Ensure the correct mode is selected for the material you are trying to detect. Refer to detection depth limits.

8. Awọn pato

Nọmba awoṣe:080.967A
Olupese:laserliner
Detection Depths:
  • Wood Studs: up to 2 cm (0.8 in)
  • Live AC Wires: up to 5 cm (2 in)
  • Non-ferrous Metal (e.g., Copper): up to 10 cm (4 in)
  • Ferrous Metal (e.g., Rebar): up to 12 cm (4.7 in)
Orisun Agbara:Ese Li-Ion Batiri
Ibudo gbigba agbara:USB-C
Awọn iwọn Ọja (L x W x H):20.5 x 8.7 x 3.8 cm (8.1 x 3.4 x 1.5 ni)
Iwọn Ọja:710 giramu (1.56 lbs)

9. Atilẹyin ọja ati Support

For information regarding warranty terms, technical support, or service, please refer to the official Laserliner webaaye tabi kan si olupin agbegbe rẹ. Jeki ẹri rira rẹ fun eyikeyi awọn ibeere atilẹyin ọja.

Awọn iwe aṣẹ ti o jọmọ - 080.967A

Ṣaajuview Laserliner StarFinder Plus: Stud and Live Wire Detector User Manual
Comprehensive user manual for the Laserliner StarFinder Plus, detailing its features for detecting wall beams, joists, and live electrical wires. Includes operating instructions, safety guidelines, technical specifications, and maintenance information.
Ṣaajuview Laserliner MultiFinder Plus User Manual: Detect Metal, Live Wires, and Studs
Comprehensive user manual for the Laserliner MultiFinder Plus, a versatile device for detecting metal, live electrical wires, and wall studs and beams. Includes operating instructions, safety guidelines, technical specifications, and maintenance tips.
Ṣaajuview MultiScanner Plus - Bedienungsanleitung
Diese Bedienungsanleitung für den Laserliner MultiScanner Plus beschreibt die bestimmungsgemäße Verwendung, Sicherheitshinweise, Inbetriebnahme, Kalibrierung und verschiedene Messmodi wie METAL-SCAN, AC-SCAN und STUD-SCAN. Enthält technische Daten und Wartungshinweise.
Ṣaajuview Laserliner Quadrum/Quadrum Green Ni kikun Aifọwọyi Yiyi Lesa - Afọwọṣe olumulo
Iwe yii pese awọn itọnisọna okeerẹ fun Laserliner Quadrum ati Quadrum Green ni kikun awọn lasers rotary laifọwọyi, awọn ẹya ara ẹrọ ti o bo, iṣẹ ṣiṣe, awọn itọnisọna ailewu, ati awọn alaye imọ-ẹrọ.
Ṣaajuview Laserliner DigiLevel Plus Digital Spirit Level - User Manual and Technical Specifications
User manual for the Laserliner DigiLevel Plus digital spirit level. Features include horizontal/vertical angle measurement, slope memory, calibration, and multiple units (° , %, mm/m). Includes detailed operating instructions, safety guidelines, maintenance, and technical specifications for models 25, 40, and 60.
Ṣaajuview Laserliner EasyCross-Lesa Bedienungsanleitung
Umfassende Bedienungsanleitung fun Laserliner EasyCross-Laser, die Funktionen, Sicherheitshinweise und technische Daten beschreibt.