ERICKHILL ROOK600C

ERICKHILL Infrared Thermometer Gun User Manual

Model: ROOK600C

1. Ifihan

The ERICKHILL Infrared Thermometer Gun is a non-contact temperature measurement device designed for various applications, including cooking, BBQ, HVAC, engine diagnostics, and pool temperature monitoring. It provides rapid and accurate temperature readings from -58°F to 1112°F (-50°C to 600°C) with a ±1.5% accuracy. Featuring adjustable emissivity and a 12:1 distance-to-spot ratio, this thermometer allows for precise measurements from a safe distance. Its user-friendly design includes a clear backlit LCD, laser targeting, and automatic shut-off for power saving.

ERICKHILL Infrared Thermometer Gun with two AAA batteries

Figure 1.1: ERICKHILL Infrared Thermometer Gun and included AAA batteries.

2. Alaye Aabo

WARNING: This device is NOT intended for measuring human or animal body temperature. It is designed for industrial and household surface temperature measurements only.

Infrared thermometer pointing at a person's forehead with a red X indicating it's not for human use.

Figure 2.1: The thermometer is not for human temperature measurement.

3. Ọja Ipariview

3.1 Package Awọn akoonu

3.2 Device irinše

Diagram of the infrared thermometer's LCD display showing various indicators like hold, scan, emissivity, Fahrenheit/Centigrade, measurement reading, backlight, laser, and low battery indicator.

Figure 3.1: LCD Display and Component Overview.

4. Eto

4.1 Fifi sori batiri

The ERICKHILL Infrared Thermometer requires two AAA batteries (included). To install or replace batteries:

  1. Locate the battery compartment on the handle of the device.
  2. Ṣii ideri iyẹwu batiri naa.
  3. Fi awọn batiri AAA meji sii, ni idaniloju polarity ti o pe (+/-).
  4. Pa ideri batiri naa ni aabo.
Image showing the battery compartment of the ERICKHILL Infrared Thermometer and two AAA batteries being inserted.

Àwòrán 4.1: Fífi bátìrì sílẹ̀.

5. Awọn ilana Iṣiṣẹ

5.1 Ipilẹ wiwọn

Lati ṣe wiwọn iwọn otutu:

  1. Point the thermometer at the target surface.
  2. Press and hold the measurement trigger. The laser pointer will activate (if enabled) to indicate the measurement spot.
  3. The temperature reading will appear on the LCD display within 0.5 seconds.
  4. Release the trigger to hold the reading on the display. The device will automatically shut off after 12 seconds of inactivity.
Icon indicating 0.5 second rapid response time.Icon indicating data hold function.

Figure 5.1: Fast response and data hold features.

5.2 Ìtújáde Tí A Lè Ṣàtúnṣe

Emissivity is the ability of a material to emit thermal energy. Different materials have different emissivity values. Adjusting the emissivity setting (EMS) on the thermometer ensures more accurate readings for various surfaces. The default value is 0.95, suitable for most organic materials and painted surfaces. You can adjust it from 0.1 to 1.0.

  1. With the device on, press the 'MODE' button. The 'EMS' indicator will appear on the display.
  2. Use the Up/Down buttons to adjust the emissivity value.
  3. Press the 'MODE' button again to confirm the setting or wait for the device to return to measurement mode automatically.
Emissivity table showing different materials and their corresponding emissivity values, such as Aluminum 0.30, Iron 0.70, Wood 0.94, etc.

Figure 5.2: Emissivity Table for common materials.

5.3 Ìyípadà Ẹ̀yà (°C/°F)

Láti yípadà láàrín Celsius (°C) àti Fahrenheit (°F):

Close-up of the thermometer's display and buttons, highlighting the C/F switch button.

Figure 5.3: °C/°F unit switch button.

5.4 Backlight and Laser Control

The device features a backlight for visibility in low-light conditions and a laser pointer for precise targeting.

Close-up of the thermometer's display and buttons, highlighting the backlight and laser toggle buttons.

Figure 5.4: Backlight and Laser control buttons.

5.5 Aifọwọyi tiipa

To conserve battery life, the thermometer will automatically shut down after 12 seconds of inactivity.

6. Awọn ohun elo

The ERICKHILL Infrared Thermometer Gun is suitable for a wide range of non-contact temperature measurement tasks, including but not limited to:

Collage of images showing the infrared thermometer being used in various applications: checking engine temperature, HVAC, pizza oven, BBQ, and soldering.

Figure 6.1: Wide range of applications for the thermometer.

7. Itọju

To ensure the longevity and accuracy of your ERICKHILL Infrared Thermometer:

8. Laasigbotitusita

9. Awọn pato

Ẹya ara ẹrọSipesifikesonu
Iwọn otutu-58 ° F ~ 1112 ° F (-50 ° C ~ 600 ° C)
Yiye± 1.5%
Akoko Idahun0.5 aaya
Idiwọn Ijinna-si-Aami (D:S)12:1
EmissivityAdjustable (0.1-1.0), default 0.95
Orisun agbara2 x Awọn batiri AAA (pẹlu)
Pa laifọwọyi12 aaya ti aiṣiṣẹ
Ifihan IruLCD oni-nọmba pẹlu imọlẹ ẹhin
Pataki ẸyaNon-Contact Measurement, Laser Pointer
Ọja Mefa8.11 x 7.76 x 1.81 inches
Iwọn Nkan6 iwon
Nọmba awoṣeROOK600C

10. Atilẹyin ọja ati Support

ERICKHILL provides a 3-year warranty and lifetime technical support for each product. If you have any questions or require assistance with your ERICKHILL Infrared Thermometer Gun, please do not hesitate to contact ERICKHILL customer service.

Awọn iwe aṣẹ ti o jọmọ - ROOK600C

Ṣaajuview ERICKHILL ROOK 400/600 SP IR Itanwo Itọsọna olumulo
Itọsọna olumulo fun ERICKHILL ROOK 400 SP ati ROOK 600 SP infurarẹẹdi thermometers. Pese awọn itọnisọna lori iṣẹ, awọn ẹya, ailewu, ati awọn alaye imọ-ẹrọ.
Ṣaajuview ERICKHILL ER02 EMF Mita Itọsọna olumulo
Ṣawari awọn agbara ti ERICKHILL ER02 EMF Mita pẹlu itọnisọna olumulo okeerẹ yii. Kọ ẹkọ nipa iṣẹ ṣiṣe 3-in-1 rẹ fun wiwọn ina, oofa, ati awọn aaye igbohunsafẹfẹ redio, pẹlu iṣẹ ṣiṣe, awọn pato, ati awọn itọnisọna ailewu.
Ṣaajuview Erickhill RT-100S EMF Mita olumulo Afowoyi
Itọsọna olumulo fun Erickhill RT-100S EMF Mita, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, awọn alaye imọ-ẹrọ, ati awọn ohun elo fun wiwọn ina, oofa, ati awọn aaye RF.