The Energetic 12 Gauge Trip Wire Perimeter Alarm is a robust and reusable security device designed to provide early warning against unwanted intrusions. Constructed from high-quality, rust-proof 6061 aluminum, this spring-activated alarm is ideal for protecting campsites, homes, farms, and restricted areas by creating an audible perimeter.

It functions by utilizing a hidden trip wire that, when pulled, activates a loud acoustic alarm, alerting you to potential threats. This device is intended for outdoor use only and is designed to produce a loud noise for alert purposes, not to cause harm.

Energetic 12 Gauge Trip Wire Perimeter Alarm

Image: The Energetic 12 Gauge Trip Wire Perimeter Alarm device, showcasing iwapọ ati apẹrẹ ti o tọ.

Package Awọn akoonu ati irinše

package rẹ yẹ ki o ni awọn atẹle wọnyi:

Familiarize yourself with the main components of the alarm device:

Diagram of Energetic 12 Gauge Trip Wire Perimeter Alarm components

Image: Labeled diagram of the alarm device, indicating the Pull Ring, Trigger Pin, Firing Pin, Spring/Pin Retainer, Zip-tie Mounts, Mounting Holes, Load Detent, and Breech.

Awọn ilana iṣeto

Follow these steps to properly set up your perimeter alarm:

Three-step installation guide for the Energetic 12 Gauge Trip Wire Perimeter Alarm

Image: Visual guide showing the three main steps for installing the alarm: attaching to a hard object, installing the pin and setting the trip wire, and installing the 12 gauge blank or optional pepper gas.

  1. Step 1: Attach the Alarm System

    Attach the alarm system in a vertical position to a hard object such as a tree, pole, or frame. You can use the provided mounting holes with eye screws, nails, or screws, or utilize the zip-tie notches with zip ties for secure fastening.

  2. Step 2: Install Pin and Set Trip Wire

    Once the device is securely mounted, install the trigger pin. Connect a trip wire (not included) to the trigger pin and extend it across the area you wish to protect. Ensure the trip wire is taut and positioned at a height that will be triggered by an intruder but is not easily visible.

  3. Step 3: Install 12 Gauge Blank or Optional Pepper Gas

    Carefully insert a 12 gauge blank cartridge or an optional pepper gas cartridge (not included) into the breech of the device. Always ensure the device is pointed in a safe direction and that you are clear of the firing path.

    Important Safety Note: Always remove the 12 gauge blank or optional pepper gas cartridge before disarming or moving the device to prevent accidental discharge.

Isẹ

The Energetic 12 Gauge Trip Wire Perimeter Alarm is designed for simple, effective operation:

Reloading the Device

After activation, the device can be reloaded and reused:

  1. Ensure the area is safe and the device is disarmed (no cartridge inserted).
  2. Remove any spent cartridge from the breech.
  3. Reinsert the trigger pin into its position.
  4. Insert a new 12 gauge blank or pepper gas cartridge into the breech.
  5. Re-attach or adjust the trip wire as needed.

Itoju

To ensure the longevity and reliable performance of your Energetic 12 Gauge Trip Wire Perimeter Alarm, follow these maintenance guidelines:

Laasigbotitusita

If you encounter issues with your perimeter alarm, consider the following common solutions:

IsoroOwun to le FaOjutu
Alarm does not sound when trip wire is pulled.
  • No 12 gauge blank/cartridge loaded.
  • Cartridge is faulty or expired.
  • Trigger pin not fully engaged or stuck.
  • Internal mechanism obstructed.
  • Ensure a fresh 12 gauge blank or pepper gas cartridge is properly loaded.
  • Replace with a new, reliable cartridge.
  • Check that the trigger pin moves freely and is fully inserted. Clean if necessary.
  • Inspect the breech and firing pin area for debris and clear any obstructions.
Alarm sounds accidentally.
  • Trip wire too sensitive or improperly set.
  • Environmental factors (wind, animals).
  • A ko fi ẹrọ naa sori ẹrọ lailewu.
  • Adjust trip wire tension or placement.
  • Consider a less sensitive location or higher trip wire placement if small animals are an issue.
  • Ensure the device is firmly attached to a stable object.
Difficulty inserting/removing cartridge.
  • Breech is dirty or corroded.
  • Cartridge is not the correct size or is damaged.
  • Clean the breech thoroughly.
  • Ensure you are using standard 12 gauge blank cartridges or compatible pepper gas cartridges.

Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Ọja Mefa10 x 8 x 4 cm (isunmọ 3.94 x 3.15 x 1.57 inches)
Ohun eloHigh-quality 6061 Aluminum Alloy (Rust-proof)
Àwọ̀Dudu
Iru ItanijiAcoustic (requires 12 gauge blank or pepper gas cartridge)
Muu ṣiṣẹTrip wire activated, spring-loaded firing mechanism
AtunloReloadable and reusable
Lilo ti a pinnuOutdoor perimeter security, early warning system
Reference size and warning for Energetic 12 Gauge Trip Wire Perimeter Alarm

Image: Diagram showing the approximate dimensions of the alarm device (3.62 inches tall, 1.14 inches wide) and illustrating that it is not intended for harming animals or people.

Awọn ikilọ Abo pataki

Awọn iwe aṣẹ ti o jọmọ - B0C7TFN1NP

Ṣaajuview Agbara SupValue A67 YKA67C2 LED Bulb - Awọn pato ati Iwe data
Iwe data alaye fun Energetic SupValue A67 YKA67C2 LED boolubu, ifihan awọn pato, awọn alaye ohun elo, ati tabili ọja okeerẹ pẹlu awọn awoṣe lọpọlọpọ.
Ṣaajuview Energetic DALI Dimmable Driver ECD37WCC 0500-0950 DL2: Technical Specifications & Installation
Comprehensive technical specifications, features, installation guide, and performance data for the Energetic DALI Dimmable Driver (Model ECD37WCC 0500-0950 DL2). Discover its DALI 2.0 compatibility, touch dim functionality, and multi-wattage yiyan.
Ṣaajuview SICK G10 Photoelectric Sensors: Product Family Overview
Okeerẹ loriview of the SICK G10 product family, detailing features, benefits, technical specifications, and ordering information for these powerful and versatile photoelectric sensors.
Ṣaajuview Fi sori ẹrọ Imuduro Agbara FMS Series Flushmount Fixture ati Itọsọna Aabo
Itọsọna okeerẹ fun fifi sori ẹrọ ati ṣiṣiṣẹ Imọlẹ Imọlẹ FMS jara flushmount imuduro, pẹlu alaye ailewu, yiyan CCT, awọn igbesẹ fifi sori ẹrọ, laasigbotitusita, ati awọn alaye atilẹyin ọja.
Ṣaajuview AGBÁRA Asán Ina Awọn imuduro Awọn ilana fifi sori ẹrọ
Igbese-nipasẹ-Igbese Itọsọna fifi sori ẹrọ fun ENERGETIC MLV231-L100K9027 Awọn imuduro Imọlẹ Asan, pẹlu alaye ailewu, awọn akoonu package, awọn alaye hardware, ati atilẹyin ọja.
Ṣaajuview Alagbara ina LED rinhoho Light E6SLB Series fifi sori Itọsọna
Awọn ilana fifi sori ẹrọ okeerẹ fun Imọlẹ Ina E6SLB Series LED Strip Light, aabo ibora, iṣagbesori, onirin, ati laasigbotitusita.