Wilo 4090764

Ìwé Ìtọ́sọ́nà Olùlò Wilo Star S 16 FX Circulating Pump

Àwòṣe: 4090764 | Àmì ìdámọ̀ràn: Wilo

1. Ifihan

The Wilo Star S 16 FX circulating pump is designed for efficient and reliable operation in hydronic radiant floor heating and other closed-loop system applications. Featuring a robust cast iron housing and a three-speed motor, this circulator provides optimal performance for various heating needs. Its quiet operation makes it suitable for sound-sensitive installations.

2. Alaye Aabo

ÌKÌLỌ̀: Láti dín ewu ìkọlù iná mànàmáná, iná, tàbí ìpalára kù, máa tẹ̀lé àwọn ìlànà ààbò wọ̀nyí nígbà gbogbo.

  • Do not install the pump with the motor positioned directly above or below the pump body.
  • Ọja yii jẹ apẹrẹ fun lilo inu ile nikan.
  • Refer to the complete instruction manual for proper installation procedures to prevent electric shock.
  • The maximum permissible water temperature is 230°F (110°C).
  • Use only copper conductors for electrical connections.
  • Do not operate the pump without fluid (dry run) as this can cause severe damage.
  • The pump operates on 115 Volts, 60 Hz, with a maximum current draw of 0.66 Amperes.
  • The maximum working pressure for this unit is 145 PSI.
  • The motor is Class F insulated with a -7µf capacitor.

3. Ọja Ipariview

Awọn ẹya pataki:

  • Cast iron housing for durability.
  • 90-degree rotated flanges for flexible installation.
  • Three-speed motor (Low/Medium/High) for adjustable performance.
  • Maximum head of 16 feet.
  • Built-in motor protection for extended life and improved performance.
  • Suitable for various applications including water and glycol radiant floor heating, hydronic heating, fan coil heating, and solar water heating.
  • Iṣẹ́ ìkọ̀kọ̀-ìdákẹ́jẹ́ẹ́.
  • UL/CSA listed for safety compliance.
  • A ṣe é ní ilẹ̀ Faransé.

Awọn eroja to wa:

  • 1 x Wilo Star S 16 FX Circulator Pump
  • 2 x Gaskets (O-rings)

Awọn aworan ọja:

Wilo Star S 16 FX Circulating Pump front view
Iwaju view of the Wilo Star S 16 FX circulating pump, highlighting the green cast iron body, black motor housing, and the three-speed selector dial.
Wilo Star S 16 FX Circulating Pump with included gaskets
The Wilo Star S 16 FX circulating pump shown alongside the two included O-ring gaskets, ready for installation.
Igun view of Wilo Star S 16 FX Circulating Pump
An angled perspective of the Wilo Star S 16 FX pump, showcasing its compact design and the 90-degree rotated flanges.
Wilo-Star pump performance curve chart
Performance curve chart for Wilo-Star pumps with cast iron bodies, 60 Hz, illustrating head (H) versus flow rate (Q) for various models including Star 16.
Wilo-Star S product packaging front
Iwaju view of the Wilo-Star S ClassicStar product packaging, displaying the model number (STAR S 16 FX), voltage (115 V), frequency (60 Hz), and part number (4090764).
Wilo-Star S product packaging with pump image
The Wilo-Star S product packaging, featuring an image of the pump and text indicating it is a flexible closed system pump.

4. Eto ati fifi sori

The Wilo Star S 16 FX pump is designed for straightforward installation in closed-loop heating systems. Its 90-degree rotated flanges offer flexibility in pipe connection. Ensure the system is depressurized and drained before beginning installation. Always follow local plumbing and electrical codes. The included gaskets (O-rings) should be properly seated to ensure a watertight seal.

For detailed installation steps, including pipe sizing, electrical wiring, and system filling, consult a qualified professional or the comprehensive installation guide provided with the product.

5. Awọn ilana Iṣiṣẹ

The Wilo Star S 16 FX features a three-speed motor, allowing you to adjust the pump's performance to match your system's requirements. The speed settings are typically labeled Low, Medium, and High (or 1, 2, 3, and Eco/Max on the dial).

  • Yiyan Iyara: Locate the selector dial on the front of the pump's motor housing.
  • Iyara Ṣatunṣe: Rotate the dial to select the desired speed setting. Higher settings provide greater flow and head, while lower settings consume less energy and are suitable for systems with lower demand.
  • Isẹ akọkọ: After installation and system filling, ensure all air is purged from the system before starting the pump. Start the pump on a lower speed setting and gradually increase if more flow is required.

Refer to the performance curve chart in the Product Overview section to understand the pump's capabilities at different speeds.

6. Itọju

The Wilo Star S 16 FX circulating pump is designed for minimal maintenance. Regular checks can help ensure its longevity and efficient operation:

  • Titẹ Eto: Periodically check your heating system's pressure to ensure it is within the recommended operating range.
  • Iwari ti o jo: Inspect the pump and connections for any signs of leaks. Address any leaks promptly to prevent system damage.
  • Awọn ipele Ariwo: Listen for any unusual noises during operation. Excessive noise could indicate air in the system or a mechanical issue.
  • Mimọ: Jẹ́ kí pọ́ọ̀pù àti agbègbè tó yí i ká mọ́ tónítóní kí ó má ​​sì sí ìdọ̀tí láti rí i dájú pé afẹ́fẹ́ ń fẹ́ sí i dáadáa àti láti dènà kí ó má ​​baà gbóná jù.

For any complex maintenance or repairs, it is recommended to contact a qualified HVAC technician.

7. Laasigbotitusita

This section provides general guidance for common issues. For persistent problems, consult a professional.

IsoroOwun to le FaOjutu
Fifa ko nṣiṣẹNo power; tripped breaker; motor protection activated; seized impellerCheck power supply and breaker; allow motor to cool; consult technician for seized impeller
Pump jẹ alariwoAir in system; cavitation; foreign object in pump; worn bearingsBleed air from system; check system pressure; inspect pump for obstructions; consult technician
Insufficient flow/headIncorrect speed setting; air in system; clogged filter/strainer; undersized pump for applicationAdjust speed setting; bleed air; clean filter; verify pump sizing for system requirements
Jíjó ní àwọn ìsopọ̀Improperly seated gaskets; loose connections; damaged flangesEnsure gaskets are correctly installed; tighten connections; inspect flanges for damage

8. Awọn pato

SipesifikesonuIye
BrandWilo
Nọmba awoṣe4090764
Ohun eloSimẹnti Irin
Àwọ̀Alawọ ewe
AraẸrọ iyika
Voltage115 Volts
Igbohunsafẹfẹ60 Hz
Maximum Current (I max)0.66 Amperes
Giga Igbega ti o pọju (Ori)16 Ẹsẹ
O pọju Omi otutu230°F (110°C)
O pọju Ṣiṣẹ Ipa145 PSI
Iwọn Nkan1.96 poun (890 Giramu)
Ọja Mefa7.75 x 3.25 x 8 inches
Awọn irinše to wa1 X Circulator pump, 2 X Gaskets
Orisun agbaraSolar Powered (Note: This refers to compatibility with solar heating systems, not that the pump itself is solar-powered)
OlupeseWilo
Ilu isenbaleFrance

9. Atilẹyin ọja ati Support

The Wilo Star S 16 FX circulating pump comes with a warranty covering material and workmanship. The warranty period is 24 months for materials and 30 months for workmanship from the date of purchase.

For technical support, warranty claims, or service inquiries, please contact your authorized Wilo dealer or visit the official Wilo website for contact information specific to your region. When contacting support, please have your pump's model number (4090764) and purchase details readily available.

Awọn iwe aṣẹ ti o jọmọ - 4090764

Ṣaajuview Wilo-Star RS, RSD, ST, RSG, AC Ṣiṣakoṣo fifa fifa ati Awọn ilana Ṣiṣẹ
Fifi sori okeerẹ ati awọn ilana ṣiṣe fun Wilo-Star RS, RSD, ST, RSG, AC awọn ifasoke kaakiri, ti o bo alaye gbogbogbo, ailewu, gbigbe, apejuwe, apejọ, fifi sori ẹrọ, asopọ itanna, iṣiṣẹ, itọju, ati laasigbotitusita.
Ṣaajuview Wilo-Yonos PICO: Àwọn ìlànà ìfisílé àti ìṣiṣẹ́
Ìtọ́sọ́nà kíákíá fún fífi sori ẹrọ àti ṣíṣiṣẹ́ ẹ̀rọ fifa omi Wilo-Yonos PICO. Ó ní ààbò, ìfisílẹ̀, àti ìṣiṣẹ́ fún àwọn ètò ìgbóná omi gbígbóná. Ìwé ìtọ́ni pípé wà lórí ayélujára.
Ṣaajuview Wilo-Star RS, RSD, ST, RSG, AC Ṣiṣakoṣo fifa fifa ati Awọn ilana Ṣiṣẹ
Fifi sori okeerẹ ati awọn ilana ṣiṣe fun Wilo-Star RS, RSD, ST, RSG, ati AC jara ti awọn fifa kaakiri. Ni wiwa alaye gbogbogbo, awọn itọnisọna ailewu, gbigbe, ibi ipamọ, apejuwe fifa, awọn ẹya ẹrọ, apejọ, asopọ itanna, isẹ, itọju, laasigbotitusita, ati awọn ẹya apoju.
Ṣaajuview Wilo Star Residential Wet Rotor Circulators: Installation and Operating Instructions
Comprehensive installation and operating instructions for Wilo Star Residential Wet Rotor Circulators. Covers safety, technical data, installation, electrical connection, startup, maintenance, and troubleshooting.
Ṣaajuview Fifi sori ẹrọ ati awọn ilana iṣiṣẹ Wilo-Atmos PICO
Ìtọ́sọ́nà tó péye fún ẹ̀rọ ìṣiṣẹ́ Wilo-Atmos PICO tó ń ṣiṣẹ́ dáadáa, tó bo ìfìsílé, iṣẹ́, àwọn ìṣọ́ra ààbò, àwọn ìlànà ìmọ̀ ẹ̀rọ, ìṣòro, àti ìparẹ́. Kíkà pàtàkì fún ìṣètò àti ìtọ́jú tó yẹ.
Ṣaajuview Ìtọ́sọ́nà Ìbẹ̀rẹ̀ Kíákíá fún Wilo-Yonos PICO1.0 Circulating Pump
Ìtọ́sọ́nà kúkúrú fún fífi sori ẹrọ àti ṣíṣiṣẹ́ ẹ̀rọ fifa omi Wilo-Yonos PICO1.0. Ó ní ìwífún nípa ààbò àti àwọn ìjápọ̀ sí ìwé kíkún. Ó dára fún àwọn ètò ìgbóná omi gbígbóná.