1. Ifihan
This manual provides comprehensive instructions for the safe and effective operation of the KAIWEETS KC602 Smart Clamp Meter. Please read this manual thoroughly before use and retain it for future reference.
Alaye Aabo
Always adhere to local and national safety codes. Use appropriate personal protective equipment (PPE) when working with electrical circuits. Do not exceed the maximum input values specified for the meter. Disconnect power to the circuit before making connections or disconnections.
2. Ọja Ipariview ati irinše
The KAIWEETS KC602 is an intelligent clamp meter designed for precise measurement of AC/DC current, AC/DC voltage, frequency, duty cycle, resistance, capacitance, diode, continuity, and temperature. It features a smart measurement mode, True-RMS, and a high-definition color screen.

Figure 2.1: KAIWEETS KC602 Smart Clamp Meter and included accessories, including test leads, K-type thermocouple, and carrying case.

Figure 2.2: Key features of the KC602, including automatic shutdown, CAT.IV 600V safety rating, and automatic range selection for ease of use.
Awọn akoonu idii:
- 1x KAIWEETS KC602 Smart Clamp Mita
- 1x Test Leads
- 1x K-Type Thermocouple
- 2x AAA batiri
- 1x Apo Gbigbe
- 1x Itọsọna olumulo
3. Eto
3.1 Fifi sori batiri
- Wa ideri ibi ipamọ batiri naa ni ẹhin mita naa.
- Lo screwdriver lati ṣii yara batiri naa.
- Fi awọn batiri AAA mẹta sii, ki o rii daju pe polarity ti o tọ (+ ati -).
- Rọpo ideri kompaktimenti batiri ki o ni aabo pẹlu dabaru.
3.2 Initial Power On and Calibration
Upon first power-on or after battery replacement, the KC602 performs an automatic calibration. This process ensures measurement accuracy.

Figure 3.1: The meter displays "CAL" during automatic calibration upon power-on, followed by entering Smart Mode.
The meter will automatically enter Smart Mode, which intelligently recognizes measurement signals.
4. Awọn ilana Iṣiṣẹ
4.1 Smart Measurement Mode
In Smart Mode, the KC602 automatically identifies and measures AC/DC Voltage, Resistance, and Continuity. Simply connect the test leads to the circuit, and the meter will display the relevant measurement.

Figure 4.1: The KC602 operating in Smart Mode, automatically detecting measurement signals and displaying results on its HD color screen.
4.2 Awọn iṣẹ wiwọn pato
To access specific measurement functions beyond Smart Mode, press the FUNC button to cycle through the available modes.

Figure 4.2: The KC602 offers a wide range of functions to meet diverse measurement needs.
AC / DC Iwọn Iwọn lọwọlọwọ
To measure AC/DC current, select the current mode. Open the clamp jaws and enclose a single conductor. The display will show the current reading.

Figure 4.3: Top image shows AC/DC Voltage measurement using test leads. Bottom image shows AC/DC Current measurement using the clamp jaws around a single conductor.
AC/DC Voltage Idiwon
Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack. Select the voltage mode and connect the test leads in parallel to the circuit or component to be measured.
Inrush Lọwọlọwọ wiwọn
The inrush current function measures the initial surge of current when a device is powered on. This is useful for diagnosing motor or circuit startup issues. The measurement time is approximately 100ms.

Figure 4.4: The KC602 measuring inrush current, with a measurement range of 5 to 600 A.
Non-Olubasọrọ Voltage (NCV) Idanwo
The NCV function allows for voltage detection without direct contact. Hold the NCV sensor near the conductor. The meter will indicate the presence of AC voltage with an audible beep and visual indicator.

Figure 4.5: The KC602's NCV function indicating low voltage (left) and high voltage (right) without physical contact.
Continuity, Diode, and Capacitance Tests
These functions are essential for checking circuit integrity, diode functionality, and capacitor values.

Figure 4.6: Demonstrations of Continuity Test (left), Diode Test (center), and Capacitance Test (right) using the KC602.
Iwọn Iwọn otutu
Use the included K-type thermocouple to measure temperature. Insert the thermocouple into the appropriate input jacks and place the probe on the surface or in the environment to be measured.

Olusin 4.7: Examples of various measurements: AC/DC Current (top left), AC/DC Voltage (top right), NCV (bottom left), and Temperature (bottom right).
5. Itọju
5.1 Ninu
Láti nu mita náà, fi ìpolówó nu àpótí náàamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is powered off and disconnected from any circuits before cleaning.
5.2 Batiri Rirọpo
When the battery power indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Refer to Section 3.1 for battery installation instructions.
5.3 Ibi ipamọ
Tí a kò bá lo mita náà fún ìgbà pípẹ́, yọ àwọn batiri náà kúrò kí ó má baà jẹ́ kí omi máa jò. Tọ́jú mita náà sí ibi tí ó tutù, tí ó gbẹ, tí kò sí ìmọ́lẹ̀ oòrùn tààrà àti ooru tó le koko.
5.4 Aifọwọyi Tiipa
The KC602 features an automatic shutdown function to conserve battery life. If no operation is performed within 15 minutes, the meter will automatically power off.

Figure 5.1: The meter's automatic shutdown feature activates after 15 minutes of inactivity, indicated by a countdown.
6. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Mita ko ni agbara lori. | Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ. | Ropo awọn batiri, aridaju ti o tọ polarity. |
| Awọn kika ti ko pe. | Low battery, incorrect function selected, or environmental interference. | Replace batteries, select correct function, move away from strong electromagnetic fields. |
| No display or partial display. | Battery issue or internal fault. | Check/replace batteries. If problem persists, contact customer support. |
7. Awọn pato
| Paramita | Iye |
|---|---|
| Awoṣe | KC602 |
| AC/DC Current Range | 0-600A |
| Awọn iṣiro ifihan | 6000 Awọn iṣiro |
| Otitọ-RMS | Bẹẹni |
| Laifọwọyi laye | Bẹẹni |
| Inrush Lọwọlọwọ wiwọn | Yes (5-600A, approx. 100ms) |
| Non-Olubasọrọ Voltage (NCV) | Bẹẹni |
| Orisun agbara | 2x AAA batiri |
| Iwọn Nkan | 240 g |
| Awọn iwọn | 22.6 x 11.8 x 5.2 cm |
| Aabo Rating | CAT.IV 600V, CE Certified |
8. Atilẹyin ọja ati Support
KAIWEETS provides 3 years of customer service and lifetime technical support for the KC602 Smart Clamp Meter. If you have any concerns or require assistance, please contact KAIWEETS customer support.
For support, please visit the official KAIWEETS webojú òpó wẹ́ẹ̀bù tàbí kí o kàn sí olùtajà náà tààrà nípasẹ̀ pẹpẹ tí wọ́n ti ra ọjà náà.