1. Ifihan
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Tecmojo 9U Wall Mount Network Cabinet. This cabinet is designed to securely house 19-inch IT equipment, offering features such as a lockable glass door, removable side panels, and an integrated cooling fan to ensure optimal performance and protection for your network infrastructure.
2. Alaye Aabo
- Always ensure the cabinet is securely mounted to a structurally sound wall capable of supporting the cabinet's weight plus the weight of all installed equipment. The cabinet supports up to 110 lbs (50 kg).
- Use appropriate mounting hardware for your wall type (e.g., wood studs, concrete, drywall anchors).
- Disconnect power to all equipment before performing any installation, maintenance, or adjustments inside the cabinet.
- Avoid overloading the cabinet beyond its specified weight capacity.
- Ensure proper grounding of the cabinet to prevent electrical hazards.
- Keep ventilation openings clear to maintain adequate airflow and prevent overheating.
- Do not allow children to play with or around the cabinet.
3. Package Awọn akoonu
Rii daju pe gbogbo awọn paati wa ṣaaju ki o to bẹrẹ apejọ:
- Cabinet Frame Components
- Ilẹkun Gilasi iwaju
- Awọn panẹli ẹgbẹ (2)
- Adjustable Mounting Rails (2 pairs)
- Cooling Fan (1) with power cable
- Keys (2) for door and side panels
- 10-32 Awọn skru (10)
- 10-32 Awọn eso ẹyẹ (10)
- Mounting Hole Drilling Template
- Ilana itọnisọna

Figure 3.1: Included components for the Tecmojo 9U Wall Mount Network Cabinet.
4. Eto ati fifi sori
Follow these steps to assemble and mount your Tecmojo 9U Wall Mount Network Cabinet.
4.1. Assembly Demonstration Video
Video 4.1: A step-by-step assembly demonstration for the Tecmojo Standard Wall Mount Server Cabinet.
4.2. Minisita Apejọ
- Ṣe akojọpọ fireemu naa: Begin by attaching the front frames and back cover to the bottom panel. Secure them using the provided screws.
- Install Top Cover: Place the top cover onto the assembled frame and fix the joints on both sides.
- Fasten Rack Rails: Install the adjustable rack rails inside the cabinet. These rails feature numbered U positions and square holes for easy equipment mounting. The inner mountable depth is 14.2 inches (360mm).
- Fi sori ẹrọ Awọn Paneli ẹgbẹ: Attach the two side panels to the cabinet. These panels are removable for easy access and are lockable for security.
- Install Front Glass Door: Mount the tempered glass front door. The door is reversible and can be installed to open from either the left or right side, according to your preference. It is also lockable.
4.3. Iṣagbesori Odi
- Samisi Iṣagbesori Iho: Use the provided mounting hole drilling template to mark the desired locations on the wall. Ensure the mounting holes are 16 inches apart to accommodate standard stud placement.
- Lilu ihò ki o si fi awọn ìdákọró: Drill pilot holes at the marked locations and install appropriate wall anchors if necessary (not included).
- Mount the Cabinet: Carefully lift the assembled cabinet and align its mounting holes with the installed anchors/screws on the wall. Secure the cabinet firmly to the wall.

Figure 4.1: Illustrates the cabinet's robust construction, versatile rack rails, and grounding point.

Figure 4.2: Details the mounting hole spacing and cable management features.
5. Awọn ilana Iṣiṣẹ
5.1. Itutu Fan isẹ
The Tecmojo 9U Wall Mount Network Cabinet includes a built-in top cooling fan to prevent overheating of your IT equipment. The fan operates by increasing airflow within the cabinet. Connect the fan's power cable to a suitable power source. Ensure the fan is unobstructed for optimal performance.

Figure 5.1: Key features including the cooling fan and ventilation.
5.2. Iṣakoso USB
The cabinet features removable top and bottom punch-out panels for easy cable access and management. Utilize these openings to route cables neatly, reducing clutter and improving airflow.
6. Itọju
- Ninu: Máa fọ ìta àpótí náà déédéé pẹ̀lú aṣọ rírọ̀, damp cloth. Avoid abrasive cleaners. For the glass door, use a glass cleaner.
- Afẹfẹ: Periodically check that the cooling fan and side ventilation holes are free from dust and obstructions to ensure proper airflow.
- Aabo: Ensure the door and side panel locks are functioning correctly and that the keys are kept in a secure location.
- Iduroṣinṣin Igbekale: Periodically inspect all mounting points and screws to ensure the cabinet remains securely attached to the wall.
7. Laasigbotitusita
- Awọn Ẹrọ Gbigbona Ju: Ensure the cooling fan is powered on and operating. Check that all ventilation openings are clear of obstructions. Verify that the cabinet is not overloaded with equipment, restricting airflow.
- Door/Side Panel Not Closing Properly: Check for any obstructions preventing the door or panel from closing. Ensure the hinges are not damaged or misaligned.
- Loose Cabinet: If the cabinet feels loose on the wall, immediately remove all equipment and re-secure the mounting hardware. Consult a professional if unsure about wall mounting.
8. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awọn iwọn Ọja (L x W x H) | 21.65" x 17.72" x 19.02" (550mm x 450mm x 483mm) |
| Iwọn Nkan | 37.1 iwon |
| Ohun elo | High Quality Cold Rolled Steel |
| Agbara iwuwo | Titi di 110 lbs (50 kg) |
| agbeko Sipo | 9U |
| Inner Mountable Depth | 14.2 inches (360mm) |
| Ilekun Iru | Lockable Tempered Glass Door (Reversible) |
| Awọn Paneli ẹgbẹ | Removable, Lockable |
| Itutu agbaiye | One built-in top fan, flow-through ventilation |
| iṣagbesori Iho | 16 inches apart (for stud placement) |
| Ibamu | PCI & HIPPA, EIA/ECA-310-E compliant |

Figure 8.1: Detailed dimensions and specifications of the cabinet.
9. Atilẹyin ọja ati Support
Tecmojo products are manufactured to high-quality standards. For warranty information or technical support, please refer to the official Tecmojo webojula tabi kan si wọn onibara iṣẹ taara. Tọju iwe-ẹri rira rẹ fun awọn ẹtọ atilẹyin ọja.