KAIWEETS KM401

KAIWEETS KM401 Digital Multimeter User Manual

Awoṣe: KM401

Àmì ìtajà: KAIWEETS

1. Ifihan

The KAIWEETS KM401 is a versatile and accurate digital multimeter designed for a wide range of electrical measurements. It features True RMS, 4000 counts display, and auto-ranging capabilities, making it suitable for electricians, automotive technicians, and DIY enthusiasts. This manual provides detailed instructions for safe and effective use of your KM401 multimeter.

KAIWEETS KM401 Digital Multimeter with test leads and batteries

Figure 1: KAIWEETS KM401 Digital Multimeter with included accessories.

2. Alaye Aabo

Always observe safety precautions when using electrical testing equipment. Failure to do so may result in injury or damage to the device.

3. Package Awọn akoonu

Jẹrisi pe gbogbo awọn ohun kan wa ninu package:

4. Eto

4.1 Fifi sori batiri

The KM401 multimeter requires 3 AAA batteries for operation. If the batteries are not pre-installed, follow these steps:

  1. Rí i dájú pé a ti pa multimeter náà.
  2. Wa ideri iyẹwu batiri ni ẹhin ẹyọ naa.
  3. Lo ẹ̀rọ ìdènà láti tú ìdè náà kí o sì yọ ìbòrí náà kúrò.
  4. Insert the 3 AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  5. Rọpo ideri ibi ipamọ batiri naa ki o si fi skru(s) so o mọ.

4.2 Nsopọ Awọn itọsọna Igbeyewo

To prepare the multimeter for measurements:

  1. Fi okun idanwo dudu sinu apoti titẹ sii "COM" (wọpọ).
  2. Insert the red test lead into the appropriate input jack based on the measurement type:
    • Fun Voltage, Resistance, Continuity, Diode, Capacitance, Frequency, NCV, Live, and Temperature measurements, use the "VΩHz" jack.
    • For Current measurements up to 400mA, use the "mA" jack.
    • For Current measurements up to 10A, use the "10A" jack.

5. Awọn ilana Iṣiṣẹ

5.1 Power On/Off and Auto Shut Off

5.2 Aṣayan iṣẹ

Rotate the central dial to select the desired measurement function. For functions with multiple modes (e.g., AC/DC Voltage, Diode/Continuity), press the FUNC button to cycle through the available modes.

KAIWEETS KM401 Digital Multimeter showing multi-function capabilities

Figure 2: The KM401 offers multiple measurement functions.

5.3 Awọn iwọn

5.3.1 AC / DC Voltage Idiwon

Set the rotary dial to the V~ (AC Voltage) tabi V- (DC Voltage) ipò. So àwọn ìtọ́sọ́nà ìdánwò pọ̀ ní ìfẹ̀sẹ̀tẹ̀ sí àyíká tàbí èròjà tí a fẹ́ wọ̀n. Ìfihàn náà yóò fi ìyókù hàntage kika.

KAIWEETS KM401 measuring AC/DC Voltage ati Lọwọlọwọ

Figure 3: Measuring AC/DC Voltage and Current with the KM401.

5.3.2 Ìwọ̀n Ìsinsìnyìí AC/DC

Set the rotary dial to the A~ (AC Current) or A- (DC Current) position, selecting either the mA or 10A input jack as appropriate. Connect the multimeter in series with the circuit to measure current. Ensure the circuit power is off before connecting.

5.3.3 Resistance Wiwọn

Set the rotary dial to the Ω (Resistance) position. Connect the test leads across the component to measure its resistance. Ensure the component is de-energized before measurement.

KAIWEETS KM401 performing Resistance, Capacitance, Diode, and Temperature tests

Figure 4: Various measurement capabilities including Resistance, Capacitance, Diode, and Temperature.

5.3.4 Igbeyewo Ilọsiwaju

Ṣeto ipe kiakia Rotari si Ω ipo ati tẹ FUNC to select continuity mode (indicated by a buzzer icon). Touch the test leads to the points to be tested. A continuous beep indicates continuity (low resistance).

5.3.5 Idanwo Diode

Ṣeto ipe kiakia Rotari si Ω ipo ati tẹ FUNC to select diode mode (indicated by a diode symbol). Connect the red lead to the anode and the black lead to the cathode of the diode. The display shows the forward voltage ju.

5.3.6 Iwọn Agbara

Ṣeto ipe kiakia Rotari si F (Capacitance) position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before testing.

5.3.7 Igbohunsafẹfẹ wiwọn

Ṣeto ipe kiakia Rotari si Hz (Frequency) position. Connect the test leads to the signal source. The display will show the frequency in Hertz.

5.3.8 NCV (Ti kii ṣe Olubasọrọ Voltage) Idanwo

Ṣeto ipe kiakia Rotari si NCV position. Move the top of the multimeter near a live wire or electrical outlet. The meter will beep and the NCV indicator will light up if AC voltage is detected without direct contact.

KAIWEETS KM401 performing Live and NCV tests

Figure 5: Using the KM401 for Live wire detection and Non-Contact Voltage (NCV) testing.

5.3.9 Wiwaya Laaye

Ṣeto ipe kiakia Rotari si Gbe position. Insert the red test lead into the live wire socket or touch it to the live wire. The display will indicate if the wire is live.

5.3.10 Phase Sequence Detection

The KM401 can perform phase sequence detection. Set the rotary dial to the Ipele position. Follow the on-screen prompts to connect the test leads to the phases. The meter will indicate the phase sequence.

KAIWEETS KM401 performing Phase Sequence Detection

Figure 6: The KM401's unique Phase Sequence Detection feature.

5.3.11 Wiwọn iwọn otutu

Ṣeto ipe kiakia Rotari si ° C / ° F position. Connect the thermocouple to the input jacks, observing polarity. Place the thermocouple tip on the object or in the environment whose temperature is to be measured.

5.4 Awọn iṣẹ pataki

5.4.1 Data idaduro

Tẹ awọn DIMU bọ́tìnì láti dì kíkà tó wà lórí ìbòjú náà. Tẹ̀ ẹ́ lẹ́ẹ̀kan síi láti tú iṣẹ́ ìdúró náà sílẹ̀.

5.4.2 Imọlẹ ẹhin ati Imọlẹ ina

Tẹ awọn Imọlẹ button (often combined with the HOLD button) to turn on the display backlight for improved visibility in dim conditions. Some models also feature a built-in flashlight, activated by a separate button or a long press of the light button, to illuminate the work area.

KAIWEETS KM401 with flashlight and backlight activated

Figure 7: The KM401 features a backlight for the display and a built-in flashlight.

6. Itọju

6.1 Ninu

Nu multimeter c nuasing pẹlu ipolowoamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun èlò ìfọṣọ. Rí i dájú pé ẹ̀rọ náà gbẹ pátápátá kí o tó lò ó.

6.2 Ibi ipamọ

Nigbati o ko ba wa ni lilo fun awọn akoko ti o gbooro sii, yọ awọn batiri kuro lati yago fun jijo. Tọju multimeter ni itura, aye gbigbẹ, kuro lati orun taara ati awọn iwọn otutu to gaju.

6.3 Batiri Rirọpo

Tí àmì bá hàn lórí ìbòjú, yí àwọn bátìrì padà kíákíá láti rí i dájú pé àwọn ìkà náà péye. Wo Apá 4.1 fún ìtọ́ni lórí bí a ṣe ń fi bátìrì sí.

7. Laasigbotitusita

8. Awọn pato

SipesifikesonuIye
BrandKAIWEETS
Nọmba awoṣeKM401
Orisi wiwọnMultimeter, Voltmeter
Orisun agbaraAgbara Batiri (Batiri AAA 3 to wa)
Iwọn Nkan350 giramu
Awọn iwọn Ọja (L x W x H)19.3 x 11.5 x 5.6 centimeters
Aabo RatingIEC 61010-1:2000-1 CAT. IV 600V, CAT. III 1000V
Awọn iṣiro ifihan4000 Awọn iṣiro
RMS otitọBẹẹni
Gbigbe AifọwọyiBẹẹni
Agbara Aifọwọyi PaaBẹẹni
Itọkasi Batiri KekereBẹẹni
Apọju IdaaboboBẹẹni

9. Atilẹyin ọja ati Support

KAIWEETS provides lifetime after-sale service and technical support for the KM401 Digital Multimeter. If you encounter any questions or problems while using the product, please do not hesitate to contact KAIWEETS customer support.

For assistance, please refer to the contact information provided on the KAIWEETS official webojula tabi rẹ ra Syeed.

Awọn iwe aṣẹ ti o jọmọ - KM401

Ṣaajuview KAIWEETS HT118A Digital Multimeter User Afowoyi
Itọnisọna olumulo pipe fun KAIWEETS HT118A Digital Multimeter, awọn ilana aabo ti o bo, apejuwe ọja, awọn ẹya multimeter, awọn iṣẹ wiwọn, ati awọn pato.
Ṣaajuview Ìwé Àtọ́sọ́nà Olùlò Onímọ̀ọ́nà Onímọ̀ọ́nà Onímọ̀ọ́nà Kaiweets KM601 Smart Digital
Ìwé ìtọ́ni tó péye fún Kaiweets KM601 Smart Digital Multimeter, tó ní ìwífún nípa ààbò, àwọn ẹ̀yà ara ọjà, àwọn ọ̀nà ìwọ̀n (SMART àti MANUAL), àwọn àpèjúwe ìparí, ìtọ́jú, àwọn ìlànà pàtó, àti àtìlẹ́yìn.
Ṣaajuview KAIWEETS HT113B Digital Multimeter User Afowoyi
Ìwé ìtọ́ni tó péye fún KAIWEETS HT113B Digital Multimeter, tó ṣàlàyé àwọn ẹ̀yà ara rẹ̀, àwọn ìlànà rẹ̀, àti àwọn ìlànà ìṣiṣẹ́ rẹ̀ fún ìdánwò iná mànàmáná tó péye.
Ṣaajuview KAIWEETS KM100 Digital Multimeter User Manual
Comprehensive guide to the KAIWEETS KM100 Digital Multimeter, covering safety operations, meter diagram, functions, measurement procedures for DC/AC voltage, DC current, resistance, continuity, and diode testing, along with technical specifications and maintenance.
Ṣaajuview KAIWEETS HT206D True-RMS Digital Clamp Afowoyi olumulo Mita
Ìwé ìtọ́ni tó péye fún KAIWEETS HT206D True-RMS Digital Clamp Mita. Kọ́ nípa àwọn ẹ̀yà ara rẹ̀, ìwífún nípa ààbò, àwọn ìtọ́ni ìṣiṣẹ́, àti àwọn ìlànà pàtó fún àwọn ìwọ̀n iná mànàmáná tó péye.
Ṣaajuview KAIWEETS HT206D Digital Clamp Itọsọna olumulo Mita ati Awọn pato
Okeerẹ afọwọṣe olumulo fun KAIWEETS HT206D oni clamp mita. Pẹlu awọn itọnisọna alaye lori iṣẹ, awọn iṣọra ailewu, awọn ẹya, awọn pato, ati itọju fun T-RMS AC/DC laifọwọyiamp mita.