Awọn Itọsọna Aabo pataki
Read all instructions before using this appliance. Follow all safety precautions to reduce the risk of fire, electric shock, or injury.
- Máa so mọ́ ihò ìtẹ̀sí mẹ́ta tí a ti rì mọ́lẹ̀ nígbà gbogbo. Má ṣe yọ ihò ìtẹ̀sí náà kúrò.
- Ma ṣe lo ohun ti nmu badọgba tabi okun itẹsiwaju.
- Má ṣe lo ẹ̀rọ amúlétutù èyíkéyìí pẹ̀lú okùn tàbí plug tí ó ti bàjẹ́.
- Maṣe dina awọn ṣiṣi afẹfẹ.
- Ma ṣe lo ni awọn agbegbe tutu.
- Refer to the installation instructions for proper window mounting.
Ọja Pariview
The Keystone KSTAW10INV is a 10,000 BTU window-mounted inverter air conditioner designed for efficient cooling and dehumidification of rooms up to 450 square feet. It features inverter technology for energy efficiency and quiet operation, along with a remote control for convenient use.

Iwaju view of the Keystone 10,000 BTU Window Mounted Inverter Air Conditioner, showing the control panel and air intake grille.
Awọn ẹya pataki:
- Agbara Itutu BTU 10,000: Effectively cools rooms up to 450 sq. ft.
- Imọ ọna ẹrọ oluyipada: Provides energy-efficient and quiet operation.
- Igbẹmi tutu: Ó máa ń mú omi tó tó 1.4 pints kúrò ní wákàtí kan.
- Isakoṣo latọna jijin: Faye gba atunṣe irọrun ti awọn eto lati ọna jijin.
- Ipo Ipamọ Agbara: Iṣapeye agbara agbara.
- Ipo orun: Adjusts temperature for comfortable sleep and energy savings.
- Aago 24-wakati: Programmable on/off times.
- Asọ Washable: Easy to clean for maintaining efficiency.

Illustration highlighting the 3-in-1 technology: Powerful Cooling (10,000 BTU - 450 Sq. Ft.), Air Flow (3 Fan Speeds), and Dehumidification (1.4 Pints per Hour).
Eto ati fifi sori
This section provides general guidelines for setting up your Keystone window air conditioner. For detailed instructions, refer to the included installation kit manual.
Yiyan Ibi:
- Install the unit in a window that is structurally sound and can support the unit's weight (approximately 53.1 lbs).
- Ensure the window opening is between 23 inches and 36 inches wide, and at least 19.5 inches tall.
- The unit requires a standard 115V/15A NEMA 5-15P plug. Ensure a compatible grounded outlet is nearby.

Diagram illustrating the compatible window width for installation (23-36 inches).
Awọn igbesẹ fifi sori ẹrọ (Overview):
- Prepare the window by cleaning the sill and frame.
- So awọn oke iṣagbesori iṣinipopada si awọn kuro.
- Place the unit in the window opening, ensuring it is securely seated.
- Extend the side panels to fill the window gap and secure them.
- Install the window sash seal and any additional sealing materials to prevent air leaks.
- So ẹ̀rọ náà mọ́ fèrèsé náà nípa lílo àwọn ìkọ́kọ́ àti skru tí a pèsè.
- Ensure the unit is slightly tilted outwards to allow for proper condensate drainage.

Image showing the included remote control, which allows for convenient operation from anywhere in the room.

Details of the NEMA 5-15P plug type (Standard 115V/15A) and 6.5 ft. LCDI cable length.
Awọn ilana Iṣiṣẹ
Your Keystone air conditioner offers various modes and settings for optimal comfort.
Iṣakoso Panel ati Latọna jijin:
The unit can be operated using the control panel on the front of the unit or the included remote control. The control panel features touch buttons for power, fan speed, mode selection, temperature adjustment, timer, and swing function. A digital display will show the current temperature and settings.
Official product video demonstrating the Keystone KSTAW10INV AC unit's features and operation.
Awọn ọna ṣiṣe:
- Ipo Itura: Provides cooling to the set temperature. Adjust fan speed as desired.
- Ipo Ipele: Circulates air lai itutu. Yan lati ọpọ awọn iyara àìpẹ.
- Ipo Gbẹ (Yọ eruku kuro): Din ọriniinitutu ninu yara.
- Ipo Aifọwọyi: Automatically selects cooling or fan mode based on the room temperature and set temperature.
- Heat Mode (if applicable): Provides supplemental heating. Note: Heat mode will not operate when outdoor temperature is below 41°F (5°C) and will display 'LO'. This unit is not intended as a primary heat source.
Awọn iṣẹ pataki:
- Ipo Ipamọ Agbara: The fan will turn off when the compressor cycles off and turn on when the compressor cycles on.
- Ipo orun: Gradually increases the set temperature over several hours to save energy and provide comfortable sleep.
- Aago 24-wakati: Ṣe eto ẹyọ naa lati tan tabi paa laifọwọyi lẹhin akoko ti a ṣeto.
- Iṣẹ Swing: Activates the automatic swing of the horizontal louvers to distribute air evenly.

Visual representation of the unit's energy efficiency and quiet operation, ideal for bedrooms.
Itoju
Itọju deede ṣe idaniloju iṣẹ ṣiṣe ti o dara julọ ati igbesi aye gigun ti afẹfẹ afẹfẹ rẹ.
Ninu Ajọ Afẹfẹ:
The "Check Filter" alert will illuminate after approximately 250 hours of operation. Clean the air filter every two weeks or when the "Check Filter" light appears.
- Pa ẹyọ kuro ki o yọọ kuro lati inu iṣan agbara.
- Ṣí iwájú pátákó náà.
- Grasp the handle of the filter and pull it out.
- Fi omi gbígbóná àti ọṣẹ fọ àlẹ̀mọ́ náà. Fi omi wẹ̀ ẹ́ dáadáa.
- Allow the filter to dry completely before reinserting it. Do not use hot water or dry with direct heat.
- Once the filter is reinserted, plug in the unit and press the "Filter" button on the control panel or remote to reset the filter timer.

Close-up of a hand washing the washable removable filter under running water.
Ninu Ẹka naa:
- Nu minisita nu pẹlu asọ, damp asọ.
- Maṣe lo awọn kemikali lile tabi awọn afọmọ abrasive.
- Rii daju pe ẹyọ kuro ti yọọ kuro ṣaaju ṣiṣe mimọ.
Ibi ipamọ asiko:
If storing the unit for an extended period, clean the filter and unit thoroughly. Cover the unit with plastic or cloth and store it in a dry, cool place.
Laasigbotitusita
Ṣaaju ki o to kan si atilẹyin alabara, gbiyanju awọn igbesẹ laasigbotitusita ti o wọpọ wọnyi.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹka ko ni tan-an. | No power, tripped circuit breaker, unit unplugged. | Ṣàyẹ̀wò ìsopọ̀ okùn agbára, tún ẹ̀rọ ìfọ́wọ́sí ẹ̀rọ náà ṣe, rí i dájú pé ìjáde náà ṣiṣẹ́ dáadáa. |
| Unit ko itutu fe ni. | Àlẹ̀mọ́ afẹ́fẹ́ tó dọ̀tí, èéfín tó dí, yàrá tóbi jù, ilẹ̀kùn/fèrèsé tó ṣí sílẹ̀. | Clean air filter, clear obstructions, ensure room size is within specifications, close doors/windows. |
| Ẹka jẹ alariwo. | Fífi sori ẹrọ ti ko ni wahala, idinamọ afẹfẹ, awọn ohun iṣiṣẹ deede. | Check installation for tightness, remove any obstructions, some sounds (e.g., refrigerant flow) are normal. |
| Omi ti n ṣan ni ita. | Normal condensation drainage. | This is normal. Ensure unit is slightly tilted outwards for proper drainage. |
| Heat mode displays 'LO'. | Outdoor temperature is below 41°F (5°C). | Heat mode is designed for supplemental heating and will not operate below this temperature. |
Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | KSTAW10INV |
| Agbara Itutu | 10,000 BTU |
| Ibi ti ina elekitiriki ti nwa | 115V, 60Hz |
| Agbegbe Agbegbe | Titi di 450 Sq. Ft. |
| Isokuso | 1.4 pints / Aago |
| Ariwo Ipele | 51 dB |
| Awọn iwọn Ọja (DxWxH) | 21.97" x 19.17" x 13.46" |
| Iwọn Nkan | 53.1 lbs |
| Energy Efficiency Ratio (CEER) | 14.5 |
| Pulọọgi Iru | KO 5-15P |
| USB Ipari | 6.5 ft. LCDI |

Image detailing the dimensions (19.17in W x 21.97in D x 13.46in H) and weight (54 lb) of the unit.
Atilẹyin ọja ati Support
Keystone provides a 1-year limited warranty for this product. For warranty claims or technical assistance, please contact Keystone customer support.
- Apejuwe atilẹyin ọja: 1 year limited (as per product specifications).
- Atilẹyin Onibara: Refer to the contact information provided in your product packaging or visit the official Keystone webojula.
- Awọn orisun Ayelujara: Fun afikun atilẹyin ati awọn ibeere loorekoore, ṣabẹwo si Keystone Store on Amazon.