Sonel P-6

SONEL P-6 Advanced Bipolar Voltage Atọka olumulo Afowoyi

Model: P-6 | Brand: Sonel

1. Ifihan

The Sonel P-6 is a state-of-the-art bipolar voltage indicator designed for professional electrical measurements. It offers a comprehensive range of functions including automatic AC/DC voltage detection up to 1000V, unique phase identification, continuity testing, RCD operational checks, and bipolar phase rotation testing. Engineered for safety and durability, the P-6 features a robust, IP65-rated housing, clear LCD and LED bar indications, and integrated safety alarms, making it an essential tool for electricians and technicians.

2. Alaye Aabo

Always read and understand this manual before operating the Sonel P-6. Failure to follow safety instructions may result in injury or damage to the device.

  • CAT IV 1000V Rating: This device is rated for CAT IV installations up to 1000V, indicating its suitability for measurements at the source of the low-voltage fifi sori.
  • IP65 Idaabobo: The P-6 is protected against dust ingress and low-pressure water jets from any direction. Do not immerse the device in water.
  • Ewu Voltage Alarms: The device provides acoustic and visual alarms for voltages exceeding 50V AC and 120V DC. Always treat live circuits with extreme caution.
  • Ṣayẹwo Ṣaaju Lilo: Before each use, inspect the device and test leads for any signs of damage. Do not use if damaged.
  • Aabo Batiri: Ensure correct battery polarity during installation. Replace batteries when the low battery indicator appears.
  • Oṣiṣẹ ti o peye: Only qualified and trained personnel should perform electrical measurements.

3. Ọja Ipariview ati irinše

The Sonel P-6 voltage indicator consists of two main probes connected by a flexible cable. It features an LCD display, LED indicators, and control buttons for various functions.

Sonel P-6 Voltage Indicator with accessories including probes, tips, and batteries

Nọmba 3.1: Sonel P-6 Voltage Indicator with included accessories. This image shows the main unit with its two probes, four interchangeable probe tips, two protective caps for the tips, and two AAA batteries.

3.1 Awọn eroja akọkọ:

  • Main Unit (Probe 1): Contains the LCD display, LED indicators, function buttons, and battery compartment.
  • Secondary Probe (Probe 2): Connected to the main unit via a flexible cable.
  • Ifihan LCD: Shows numerical voltage readings, resistance, and other measurement data.
  • LED Bar Indicators: Provide optical indication of voltage levels (e.g., 12V, 24V, 50V, 120V, 230V, 400V, 690V, 1000V).
  • Awọn bọtini iṣẹ: For RCD test, HOLD function, and backlight.
  • Awọn imọran Iwadii: Interchangeable tips for various applications.
  • Awọn bọtini aabo: For safe storage of probe tips.

3.2 alaye Views:

Sun mo tipetipe views of the Sonel P-6 showing probe connections, display, and cable attachment

Nọmba 3.2: Alaye views of the Sonel P-6, highlighting the secure connection points of the probes, the clear LCD and LED display area, and the robust cable attachment, ensuring durability and reliable performance.

4. Eto

4.1 Fifi sori batiri:

The Sonel P-6 requires 2 AAA batteries (included). To install or replace batteries:

  1. Locate the battery compartment on the rear of the main unit.
  2. Ṣii ideri batiri naa.
  3. Insert 2 AAA batteries, ensuring correct polarity as indicated inside the compartment.
  4. Pa ideri batiri naa ni aabo.

4.2 Attaching Probe Tips:

Select the appropriate probe tips for your measurement task and securely attach them to the probes.

5. Awọn ilana Iṣiṣẹ

5.1 Automatic AC/DC Voltage Iwọn:

The P-6 automatically detects and displays AC or DC voltage. Connect the two probes to the circuit under test. The voltage will be indicated on the LCD display and by the LED bar.

Sonel P-6 measuring voltage in a wall socket, showing LCD and LED bar indications

Nọmba 5.1: The Sonel P-6 in use, measuring voltage in a wall socket. The LCD displays the voltage reading, and the LED bar indicates the voltage range, providing clear and immediate feedback.

5.2 Phase Identification:

The Sonel P-6 is capable of unique phase identification. When measuring AC voltage, the device will indicate the phase line.

5.3 Idanwo Itẹsiwaju:

To test for continuity, connect the probes across the component or circuit path. The device will provide an audible and visual indication if continuity is detected.

5.4 RCD Function Test:

The P-6 includes a function for testing Residual Current Devices (RCDs) with an additional load. Refer to the on-screen prompts or specific instructions for this test.

5.5 Bipolar Phase Rotation Test:

For three-phase systems, the P-6 can perform a bipolar phase rotation test to determine the correct phase sequence.

5.6 HOLD Function:

Press the "HOLD" button to freeze the current measurement reading on the LCD display for easier recording or analysis.

5.7 Imọlẹ atẹhin:

Press the backlight button to illuminate the LCD display for better visibility in low-light conditions. The device also has an integrated flashlight.

6. Itọju

6.1 Ninu:

Nu ẹrọ naa pẹlu asọ, damp Aṣọ. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun èlò ìfọṣọ. Rí i dájú pé ẹ̀rọ náà gbẹ kí o tó kó o pamọ́ tàbí kí o tó lò ó.

6.2 Ibi ipamọ:

Store the Sonel P-6 in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.

6.3 Iyipada Batiri:

Replace batteries promptly when the low battery indicator appears on the display to ensure accurate measurements and proper device function.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Ẹrọ naa ko ṣiṣẹ.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Ṣayẹwo polarity batiri; ropo awọn batiri.
Awọn kika ti ko pe.Low battery; damaged probes/leads; incorrect measurement technique.Replace batteries; inspect probes for damage; review awọn ilana iṣẹ.
No continuity indication.Open circuit; faulty probes.Verify circuit integrity; check probes for damage.

8. Imọ ni pato

Ẹya ara ẹrọSipesifikesonu
Nọmba awoṣeP-6
O pọju Ṣiṣẹ Voltage1000 Volts
Orisi wiwọnVoltmeter (AC/DC), Resistance, Continuity, Phase Rotation
Ingress Idaabobo (IP) RatingIP65
Apọjutage ẸkaNran IV
Orisun agbara2 x Awọn batiri AAA (pẹlu)
Awọn iwọn33.1 x 9.3 x 5.6 cm (13.03 x 3.66 x 2.2 inches)
Iwọn430 g (0.95 lbs)
Àwọ̀ọsan

9. Atilẹyin ọja ati Support

For warranty information and technical support, please contact Sonel customer service or visit the official Sonel webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira.

Manufacturer: Sonel

Awọn iwe aṣẹ ti o jọmọ - P-6

Ṣaajuview Sonel MIC-2511 Insulation Resistance Meter - Measure up to 2 TΩ
The Sonel MIC-2511 is a versatile insulation resistance meter capable of measuring up to 2 TΩ. Features include adjustable test voltages up to 2500V, EPA measurements, data logging, and compatibility with the Sonel MeasureEffect™ platform. Ideal for industrial, residential, and telecommunications applications.
Ṣaajuview Sonel CMP-1015-PV Digital Clamp Meter for Photovoltaic Installations
Detailed information on the Sonel CMP-1015-PV digital clamp meter, designed for photovoltaic installations. Features include high DC voltage measurement up to 3000V DC, VFD function, modern clamp design, wireless communication via Bluetooth, and robust construction. Includes technical specifications, standard, and optional accessories.
Ṣaajuview Sonel AHV-3 High Voltage DC Adapter User Manual
Detailed user manual for the Sonel AHV-3 adapter, designed for measuring high DC voltages in conjunction with compatible master meters. Covers safety, operation, technical specifications, and maintenance.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Ìpa Èròjà - Sónẹ́lì Ìwọ̀n Sonel
Comprehensive user manual for the Sonel MeasureEffect platform, detailing how to take measurements, store and manage data, and control instruments. Covers interface configuration, connections, electrical safety, measurements, special features, and troubleshooting.
Ṣaajuview Sonel AHV-3 High Voltage DC Adapter User Manual
User manual for the Sonel AHV-3 adapter, detailing its features, safety precautions, technical specifications, and usage instructions for high voltage DC measurements.
Ṣaajuview Sonel CMP-400 AC Clamp Afowoyi olumulo Mita
User manual for the Sonel CMP-400 AC Clamp Meter, detailing its features, operation, safety precautions, and technical specifications for electrical measurements including AC current, voltage, resistance, frequency, and temperature.