Anern AN-SCI-MAX 10,2kW 48V

Anern 10200W Hybrid Solar Inverter

Ilana itọnisọna

1. Ọja Ipariview

The Anern 10200W Hybrid Solar Inverter is a high-performance device designed to efficiently convert solar energy into usable AC power for your home or business. It integrates a pure sine wave inverter, a 160A MPPT solar charge controller, and a battery charger into one compact unit. This inverter is compatible with various battery types and offers flexible operating modes to optimize energy usage.

Anern 10200W Hybrid Solar Inverter front view

Figure 1: Anern 10200W Hybrid Solar Inverter

Aworan yii ṣe afihan iwaju view of the Anern 10200W Hybrid Solar Inverter, showcasing its sleek design and integrated display panel.

2. Alaye Aabo

Jọ̀wọ́ ka gbogbo ìtọ́ni àti ìkìlọ̀ dáadáa kí o tó fi sori ẹ̀rọ àti ṣiṣẹ́. Àìtẹ̀lé àwọn ìtọ́ni wọ̀nyí lè yọrí sí ìkọlù iná mànàmáná, iná, tàbí ìpalára ńlá.

  • Fifi sori gbọdọ wa ni ošišẹ ti nipasẹ oṣiṣẹ eniyan.
  • Rii daju pe gbogbo onirin ti wa ni iwọn ti o tọ ati ti sopọ daradara.
  • Do not attempt to disassemble or repair the inverter. Contact qualified service personnel.
  • Jeki oluyipada kuro lati awọn ohun elo ina, ọrinrin, ati imọlẹ orun taara.
  • Rii daju pe fentilesonu to dara ni ayika ẹrọ oluyipada lati ṣe idiwọ igbona.
  • Always disconnect all power sources (PV, battery, and AC) before performing any maintenance or wiring.

3. Awọn ẹya Ọja

  • 10200W Solar Inverter 48VDC: 10.2KW Off Grid Solar Inverter 48Vdc to 230Vac with 160A MPPT Solar Charge Controller. Max PV input power: 10200W; PV operating voltage range: 90Vdc-450Vdc; Max.PV Array Open Circuit Voltage: 500Vdc; Max PV charging current: 130Amp; Rated output current: 44.3Amp; Max.PV Array Power: PV1 Channel: 5400W; PV2 Channel: 5400W; IMax.PV: PV1 Channel: 18A; PV2 Channel: 18A.
  • Dual PV Input / Dual AC Output: The MAX 10.2kw dual input has two independent MPPTs, two circuits with a total of 36A, capable of connecting higher power solar modules. Dual Output - If there is no PV and grid feed-in and the battery voltage is too low, the primary circuit switches off and only the secondary output is maintained, similar to super power saving mode.
  • Compatible with all types of batteries: The solar inverter is compatible with AGM, Gel, Lead-acid, Lithium, and Lithium Iron Phosphate batteries and supports battery-less operation mode. It supports solar, grid, or generator power for charging batteries. The inverter's charging and discharging time can be flexibly set.
  • 4 Output Modes 3 Charging Modes: The solar inverter can set the battery charging current via the LCD display; 4 output modes: Solar Priority (SUB), Utility Priority (USB) and SBU mode, MKS. 3 charging modes to choose from: Solar First (CSO), Solar Only (OSO), Solar Mixed and Utility (SNU) for various applications.
  • Idaabobo Gbigba agbara ailewu: Features short circuit protection, overcurrent protection, overvoltage Idaabobo, undervoltage protection, overload protection, backfill protection, overtemperature protection, and overload protection. Comprehensive protection for safer and more secure charging.

4. Package Awọn akoonu

Daju pe gbogbo awọn ohun kan wa ninu package rẹ:

  • Ilana itọnisọna
  • Module WiFi

5. Ọja irinše

Familiarize yourself with the main components and connection points of the inverter:

Diagram showing the front and rear components of the Anern Hybrid Solar Inverter, including LCD display, status indicators, function keys, AC input/output, PV inputs, battery input, and communication port.

Figure 2: Inverter Components Overview

This diagram illustrates the various components of the inverter, highlighting the LCD display for monitoring, touch buttons for control, and connection points for AC input, main and secondary AC outputs, PV inputs, battery connections, and the communication port for the WiFi module.

6. Eto ati fifi sori

6.1. Unboxing and Initial Setup (WiFi Module)

This video demonstrates the unboxing process and how to connect the WiFi module to your inverter for remote monitoring.

Video 1: MAX WIFI Connection

This video guides you through the process of unboxing your new Anern Hybrid Solar Inverter and connecting the included WiFi module. It shows how to attach the WiFi module to the inverter's communication port.

6.2. Wiring Awọn isopọ

Follow these steps for proper and safe wiring of the inverter:

Diagram illustrating the connections for the Anern 10200W Hybrid Solar Inverter, showing PV input, battery connections, and AC output.

Figure 3: Inverter Wiring Diagram

This image provides a visual guide for connecting the solar panels to the PV input, the 48V battery bank, and the AC loads to the inverter's output. It also highlights recommended cable sizes and fuse ratings.

Video 2: Inverter Wiring

This video provides a step-by-step guide for wiring the inverter. It covers connecting the battery terminals, solar PV panels, the essential ground wire, and the AC input and output connections. Proper wiring is crucial for safe and efficient operation.

6.3. Starting the Inverter

Follow the correct sequence to power on your inverter:

  • Rii daju pe gbogbo awọn asopọ onirin wa ni aabo ati pe o tọ.
  • Turn on the battery switch first.
  • Then, turn on the inverter's power switch.
  • Allow the inverter to initialize. Once operational, you can connect AC and PV inputs.

Video 3: How to Start the Inverter

This video demonstrates the correct sequence for starting the Anern Hybrid Solar Inverter, including turning on the battery and then the inverter. It also provides important attention points regarding AC and PV inputs.

7. Awọn ilana Iṣiṣẹ

7.1. Understanding Display and Controls

The inverter features an intuitive LCD display and touch buttons for monitoring and configuration.

Diagram showing the RGB working modes of the Anern Hybrid Solar Inverter, indicating different light colors for Battery, Utility, and PV modes.

Figure 4: RGB Working Modes

The inverter features an RGB light indicator that changes color based on its operating mode: red for battery mode, blue for utility mode, and purple for PV mode. This provides a quick visual status of the inverter's power source.

7.2. Batiri Voltage Settings (Lithium)

To optimize performance and battery lifespan, you can adjust specific voltage parameters for lithium batteries:

  • Item 05: "User-Defined" - Select this option for custom lithium battery settings.
  • Item 26: Set charging protection voltage - Define the maximum voltage fun gbigba agbara.
  • Item 27: Set float charge voltage - Configure the voltage for maintaining a full charge.
  • Item 29: Set discharge protection voltage - Set the minimum voltage before discharge cutoff.

Video 4: Lithium Battery Setting

This video demonstrates how to configure the lithium battery voltage settings directly on the inverter's LCD panel. It covers setting the charging protection voltage (item 26), float charge voltage (item 27), and discharge protection voltage (item 29) for optimal battery health and performance.

7.3. Output and Charging Modes

The inverter offers various modes to suit different energy management strategies:

Diagram explaining the four output modes (SUB, USB, SBU, MKS) and three charging modes (Solar First, Solar Only, Solar Mixed and Utility) of the Anern Hybrid Solar Inverter.

Figure 5: Output and Charging Modes

The inverter offers flexible operation with four output modes: Solar Priority (SUB), Utility Priority (USB), SBU mode, and MKS. It also provides three charging modes: Solar First (CSO), Solar Only (OSO), and Solar Mixed and Utility (SNU), allowing users to optimize energy flow based on their needs.

8. Awọn Itọsọna Itọju

Regular maintenance ensures optimal performance and longevity of your inverter:

  • Pa inverter mọ ki o si wa ninu eruku.
  • Rí i dájú pé afẹ́fẹ́ tó péye wà ní àyíká ẹ̀rọ náà.
  • Periodically check all connections for tightness and signs of wear.
  • Inspect the cooling fans for obstructions and proper operation.
Image showing the removable dust filter and intelligent cooling fans of the Anern Hybrid Solar Inverter, highlighting ease of maintenance.

Figure 6: Removable Dust Filter and Cooling Fans

The inverter is equipped with a removable dust filter to prevent dust-induced short circuits and intelligent cooling fans for efficient heat dissipation, ensuring long-term reliability. Regular cleaning of the dust filter is recommended.

9. Laasigbotitusita wọpọ oran

Ti o ba pade awọn ọran, tọka si awọn iṣoro ti o wọpọ ati awọn ojutu wọnyi:

  • Ko si Ijade agbara: Check battery connections, input voltage, and ensure the inverter is turned on.
  • Itaniji apọju: Dín ẹrù tí a so pọ̀ kù. Rí i dájú pé gbogbo agbára tí a ń lò kò ju agbára tí a fi ṣe àyẹ̀wò fún ẹ̀rọ amúṣẹ́dá.
  • Itaniji iwọn otutu giga: Check for proper ventilation, clean dust filters, and ensure ambient temperature is within operating limits.
  • Batiri Low Voltage: Check battery charge level and charging sources (solar/utility).
Iconographic representation of various protection features of the Anern Hybrid Solar Inverter, including short circuit, overcurrent, overvoltage, undervoltage, overload, backfill, and overtemperature protection.

Àwòrán 7: Àwọn Ẹ̀yà Ààbò Gbogbogbò

The inverter incorporates comprehensive protection mechanisms such as short-circuit, overcurrent, overvoltage, undervoltage, overload, backfill, and overtemperature protection to ensure safe and reliable operation.

10. Imọ ni pato

SipesifikesonuIye
Nọmba awoṣeAN-SCI-MAX 10,2kW 48V
Wattage10200 Wattis
Orisun agbaraSolar & Battery Powered
Ọja Mefa53 x 26 x 69 cm; 17 kilo
Max. PV Array Power (PV1/PV2)5400W / 5400W
PV Ṣiṣẹ Voltage Ibiti90Vdc-450Vdc
O pọju. PV orun Open Circuit Voltage500Vdc
O pọju. Gbigba agbara lọwọlọwọ PV130Amp
Ti won won Jade Lọwọlọwọ44.3Amp
AC Input Voltage230V
AC wu Voltage220V/230V

11. Atilẹyin ọja ati Onibara Support

Anern provides a 1-year warranty for this product. For technical support, troubleshooting, or warranty claims, please contact Anern customer service through the official channels. When contacting support, please provide your product model number and purchase details for faster assistance.

Fun alaye diẹ sii, ṣabẹwo si Anern Store.

Awọn iwe aṣẹ ti o jọmọ - AN-SCI-MAX 10,2kW 48V

Ṣaajuview ANERN FGI-S12000 Hybrid Solar Inverter User Manual
User manual for the ANERN FGI-S12000 Hybrid Solar Inverter. This guide details the installation, operation, safety, and specifications of the 12KW solar energy storage system, featuring MPPT charge control and UPS functionality.
Ṣaajuview Anern Pure Sine Wave Hybrid Inverter Afọwọṣe: Fifi sori, Aabo, ati Itọsọna Iṣiṣẹ
Itọsọna olumulo yii n pese aabo okeerẹ, fifi sori ẹrọ, ati awọn itọnisọna iṣẹ ṣiṣe fun Anern Pure Sine Wave Hybrid Inverter. O ni wiwa alaye pataki lori awọn irinṣẹ, onirin, ati iṣeto eto fun awọn solusan agbara igbẹkẹle.
Ṣaajuview Manuale Utente Inverter Solare Ibrido AN-SCI-MAX-10200
Questo manuale utente fornisce istruzioni pipe fun l'installazione, il funzionamento e la risoluzione dei problemi dell'Inverter Solare Ibrido AN-SCI-MAX-10200. Copre linee guida di sicurezza, architettura del sistema, process di connessione, modalità operative, specifiche and manutenzione.
Ṣaajuview AN-SCI-EVO-2000 & AN-SCI-EVO-3200 Ilana Olumulo Oluyipada
Iwe afọwọkọ olumulo pipe fun Anern AN-SCI-EVO-2000 ati AN-SCI-EVO-3200 Pure Sine Wave Solar Hybrid Inverters. Ni wiwa fifi sori ẹrọ, iṣẹ ṣiṣe, awọn pato, ati laasigbotitusita.
Ṣaajuview Itọsọna olumulo: Arabara Inverter 3.6KW/4.2KW/6.2KW
Iwe afọwọkọ olumulo pipe fun awọn awoṣe Anern Hybrid Inverter 3.6KW, 4.2KW, ati 6.2KW. Ni wiwa fifi sori ẹrọ, iṣẹ ṣiṣe, awọn pato, laasigbotitusita, ati faaji eto fun awọn solusan agbara igbẹkẹle.
Ṣaajuview Anern AN-SCI-EVO Series Hybrid Inverter User Manual
User manual for the Anern AN-SCI-EVO series hybrid inverters, including models AN-SCI-EVO-4200 and AN-SCI-EVO-6200. Provides information on installation, operation, and specifications for powering home and office appliances.