Keystone KSTHW25B

Keystone 23,200 BTU Window-Wall Air Conditioner User Manual

Awoṣe: KSTHW25B

1. Ifihan

Thank you for choosing the Keystone 23,200 BTU Window-Wall Air Conditioner with Supplemental Heat and Dehumidifier. This manual provides essential information for the safe and efficient operation of your appliance. Please read it thoroughly before installation and use, and retain it for future reference.

2. Alaye Aabo

Awọn Itọsọna Aabo pataki:

  • This appliance requires a special 230-volt/25-amp electrical outlet (NEMA 6-30P plug). Do not use with a standard 115V household outlet. Consult a qualified electrician if you are unsure about your electrical supply.
  • Máa yọ agbára kúrò kí o tó sọ ọ́ di mímọ́ tàbí kí o tó tún un ṣe.
  • Ma ṣe ṣiṣẹ ẹyọ naa pẹlu okun agbara ti o bajẹ tabi pulọọgi.
  • Rii daju didasilẹ to dara lati dinku eewu ti mọnamọna.
  • Jeki awọn ohun elo apoti kuro ni arọwọto awọn ọmọde.
  • The supplemental heating mode is not intended as a primary heat source. Use it to support your main heating system when outdoor temperatures are between 23°F and 76°F.

3. Ọja Ipariview

The Keystone KSTHW25B is a versatile air conditioning unit designed for both window and through-the-wall installation. It offers multiple functions to maintain indoor comfort.

Awọn ẹya pataki:

  • Agbara Itutu: 23,200 BTU, o dara fun awọn yara to iwọn 1,500 sq. ft.
  • Atunse Afikun: 16,000 BTU, for use when outdoor temperatures are between 23°F and 76°F.
  • Igbẹmi tutu: Ó máa ń mú omi tó tó 5.7 pints kúrò ní wákàtí kan.
  • Išẹ Olufẹ: Circulates air with multiple fan speeds.
  • Iṣakoso Latọna jijin Smart: Features a 'Follow Me' function for precise temperature sensing.
  • Àwọn Ọ̀nà Ìfipamọ́ Agbára: Includes 'Energy Saver' and 'Sleep' modes.
  • Irọrun fifi sori ẹrọ: Designed for window or through-the-wall installation with a removable chassis.
Iwaju view of the Keystone 23,200 BTU Window-Wall Air Conditioner

olusin 3.1: Iwaju view of the Keystone KSTHW25B Air Conditioner.

Diagram showing 4-in-1 technology: Powerful Cooling, Dehumidification, Air Flow, Supplemental Heat

Olusin 3.2: Pariview of the unit's 4-in-1 functionality.

4. fifi sori

The KSTHW25B unit can be installed in a window or through an exterior wall. A window installation kit is included.

4.1 Electrical ibeere

This unit requires a dedicated 230-volt, 25-amp circuit with a NEMA 6-30P plug. Ensure your electrical system can support these requirements before installation. Do not use extension cords or adapters.

Image showing the AC unit installed in a window with a power cord connected to a 230V/25A NEMA 6-30P outlet.

Figure 4.1: Electrical connection details for the 230V/25A NEMA 6-30P plug.

4.2 Window fifi sori

The unit comes with an adjustable window kit. The minimum window height required for installation is 19.5 inches. Compatible window widths range from 31 to 42 inches.

Image showing the AC unit installed in a window with text indicating compatible window width of 31-42 inches and 'Easy Installation'.

Figure 4.2: Window installation with compatible width range.

AC unit installed in a window in a bedroom setting.

Olusin 4.3: Example of window installation.

4.3 Through-the-Wall Installation

The unit features a removable chassis for through-the-wall installation. Refer to the detailed instructions provided in the separate installation guide for specific wall sleeve requirements and procedures.

5. Awọn ilana Iṣiṣẹ

Your Keystone air conditioner can be operated using the control panel on the unit or the included smart remote control.

5.1 Iṣakoso latọna jijin

The smart remote control features a 'Follow Me' function, which senses the temperature at its location and sends this data to the unit every 3 minutes for optimized comfort. This allows the unit to adjust its operation based on the temperature where you are, rather than just at the unit's location.

Hand holding the Keystone remote control with the AC unit visible in the background.

Figure 5.1: Smart remote control for convenient operation.

5.2 Awọn ọna ṣiṣe

  • Ipo Itura: Provides cooling for the room. Adjust temperature and fan speed as desired.
  • Heat Mode (Supplemental): Provides supplemental heating. This mode is effective when outdoor temperatures are between 23°F and 76°F. It is not designed to be a primary heat source during colder months.
  • Ipò Ìtújáde: Reduces humidity in the room. The fan operates at a low speed in this mode.
  • Ipo Ipele: Circulates air without cooling or heating. Select desired fan speed (Low, Medium, High).

5.3 Energy-Saving Features

  • Ipo Ipamọ Agbara: The fan will cycle on and off with the compressor to reduce energy consumption.
  • Ipo orun: Gradually increases the set temperature over several hours to save energy and provide comfortable sleeping conditions.
  • Aago 24-wakati: Allows you to program the unit to turn on or off automatically within a 24-hour period.
Image of a person sleeping in bed with text 'ENERGY EFFICIENT Sleep mode gradually increases room temperature to save energy'.

Figure 5.2: Sleep mode for energy efficiency and comfort.

6. Itọju

Itọju deede ṣe idaniloju iṣẹ ṣiṣe ti o dara julọ ati igbesi aye gigun ti afẹfẹ afẹfẹ rẹ.

6.1 Air Filter Cleaning

The unit is equipped with a mesh air filter. A 'Filter Light Reminder' will illuminate to indicate when the filter needs cleaning. To clean:

  1. Ge asopọ agbara si ẹyọkan.
  2. Remove the front panel and slide out the air filter.
  3. Wẹ àlẹmọ pẹlu gbona, omi ọṣẹ. Fi omi ṣan daradara.
  4. Gba àlẹmọ laaye lati gbẹ patapata ṣaaju fifi sori ẹrọ.
  5. Reinstall the filter and front panel, then restore power.

6.2 Gbogbogbo Cleaning

Mu ese ita kuro pẹlu asọ, damp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure the drainage area is clear of obstructions.

7. Laasigbotitusita

Ṣaaju ki o to kan si atilẹyin alabara, tunview Awọn iṣoro ti o wọpọ ati awọn solusan wọnyi:

IsoroOwun to le FaOjutu
Ẹka ko ni tan-anKò sí agbára, ẹ̀rọ ìdènà ìṣiṣẹ́ tí ó ti bàjẹ́, páálí tí ó dẹ̀.Check power supply, reset breaker, ensure plug is fully inserted.
Insufficient itutu / alapapoDirty air filter, blocked air intake/outlet, room too large, doors/windows open.Clean filter, clear obstructions, ensure proper room size, close doors/windows.
Omi ti n ṣan ni itaNormal operation (condensation).This is normal during cooling/dehumidifying. Ensure proper drainage.
Unit jẹ alariwoLoose parts, unit not level, fan obstruction.Check for loose components, ensure unit is level, clear fan area.

8. Awọn pato

Technical details for the Keystone KSTHW25B Air Conditioner:

Image showing the AC unit with its dimensions: 25.4 inches wide, 23.6 inches deep, 17.9 inches high, and a weight of 121 lbs.

Figure 8.1: Physical dimensions and weight of the unit.

Room Size Guide table showing 25,000 BTU for 1,500 Sq. Ft. and 18,000 BTU for 1,000 Sq. Ft.

Figure 8.2: Room size guide based on BTU capacity.

SipesifikesonuIye
Nọmba awoṣeKSTHW25B
Agbara Itutu23,200 BTU
Supplemental Heating Power16,000 BTU
Pakà Area IderiTiti di 1,500 Sq. Ft.
Voltage230 Volts
Dehumidifier Agbara5.7 pints / aago
Ariwo Ipele56.3 dB
Awọn iwọn Ọja (D x W x H)25.39 x 23.62 x 17.91 inches
Iwọn Nkan121 iwon
Fọọmù ifosiweweWindow/Wall
BEE Star Rating4 Irawo
Ipin Iṣiṣẹ Agbara Igba Igba (SEER)9.4
Awọn irinše to waAC unit, remote, batteries, mesh air filter, window installation kit

9. Atilẹyin ọja ati Support

9.1 atilẹyin ọja Alaye

This Keystone air conditioner comes with a 1-odun atilẹyin ọja covering parts and labor. Additionally, there is an extended 4-odun atilẹyin ọja specifically for the sealed system components.

Jọwọ ṣe idaduro ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

9.2 Onibara Support

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact Keystone customer support. Refer to the contact information provided with your product packaging or visit the official Keystone webaaye fun awọn alaye atilẹyin lọwọlọwọ.

Awọn iwe aṣẹ ti o jọmọ - KSTHW25B

Ṣaajuview Keystone KSTAT10-2D Air Conditioner Installation Instructions
Comprehensive installation guide for the Keystone KSTAT10-2D air conditioner, detailing wall sleeve preparation, unit mounting, and finishing steps for various wall sleeve brands including Emerson, Fedders, Whirlpool, White-Westinghouse, Frigidaire, Carrier, General Electric, Hotpoint, Sears, Kenmore, and Friedrich.
Ṣaajuview Ferese Keystone/Iyẹwu Odi Afọwọṣe Olumulo Amulomu KSTHW08A KSTHW12A
Iwe afọwọkọ olumulo pipe fun window Keystone ati awọn amúlétutù yara iru ogiri, awọn awoṣe KSTHW08A ati KSTHW12A. Pẹlu awọn itọnisọna ailewu, awọn itọsọna fifi sori ẹrọ, awọn ẹya iṣẹ, itọju, ati awọn imọran laasigbotitusita.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò fún Fèrèsé Keystone/Yàrá Irú Ògiri
This user's manual provides important safety instructions, installation guidance, operating instructions, care and cleaning tips, troubleshooting advice, and warranty information for Keystone window/wall-type room air conditioners.
Ṣaajuview Keystone KSTAT12-2C - 2016 Air Conditioner Owner's Manual & Installation Guide
Comprehensive owner's manual and installation guide for the Keystone KSTAT12-2C - 2016 Window/Wall-Type Room Air Conditioner. Includes safety, features, installation, care, troubleshooting, and warranty information.
Ṣaajuview Keystone KSTAT14-2D Installation Instructions
Comprehensive installation guide for the Keystone KSTAT14-2D air conditioner, detailing wall sleeve preparation, unit mounting, and finishing touches for optimal performance and safety.
Ṣaajuview Ìwé Ìtọ́sọ́nà fún lílo àti ìtọ́sọ́nà fún fífi afẹ́fẹ́ inú yàrá Keystone KSTHW18B/KSTHW25B
Ìwé ìtọ́ni tó péye nípa lílo àti ìtọ́sọ́nà ìfisílé fún àwọn afẹ́fẹ́ inú yàrá Keystone KSTHW18B àti KSTHW25B tí wọ́n ń lo fèrèsé/ogiri, tó ní ààbò, ìṣètò, iṣẹ́, àwọn ẹ̀yà ara rẹ̀, ìtọ́jú àti ìṣòro tó ń yọjú. Ó ní àtìlẹ́yìn àti ìwífún nípa ìforúkọsílẹ̀.