1. Ifihan
Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.
2. Awọn ilana aabo
Nigbagbogbo ṣe akiyesi awọn iṣọra ailewu atẹle lati yago fun ipalara tabi ibajẹ si ẹrọ naa:
- Aabo Itanna: Ensure the device is connected to a properly grounded power outlet. Do not open the casing; ko si awọn ẹya olumulo-iṣẹ inu. Tọkasi gbogbo iṣẹ si oṣiṣẹ oṣiṣẹ.
- Asopọ batiri: Connect the battery with correct polarity (red to positive, black to negative). Incorrect connection can cause severe damage to the inverter and battery. Use a 12V DC battery with a capacity between 50-200 Ah (55 Ah suggested).
- Afẹfẹ: Ensure adequate ventilation around the unit. Do not block the fan or ventilation openings. Overheating can lead to device malfunction or damage.
- Ayika: Operate the device within the specified temperature range of 0 - 40°C and humidity of 10 - 90%. Avoid direct sunlight, moisture, dust, and corrosive environments.
- Idaabobo Apọju: Do not exceed the rated power of 700 W. The device is equipped with overload protection, but continuous overloading can shorten its lifespan.
- Olubasọrọ olomi: Keep the device away from liquids. In case of accidental liquid contact, immediately disconnect power and consult a service technician.
- Awọn ọmọde ati awọn ohun ọsin: Jeki ẹrọ naa kuro ni arọwọto awọn ọmọde ati awọn ohun ọsin.
3. Ọja irinše
Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

olusin 3.1: Iwaju Panel
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

olusin 3.2: Ru Panel Loriview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.
Figure 3.3: Rear Panel Connections Detail
A jo view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.
Awọn eroja pataki:
- Ifihan LED: Provides real-time information on operating status, battery charge level, and load level.
- Main ON/OFF Switch: O n ṣakoso agbara si inverter.
- Awọn ibọsẹ Ijade AC: Two 230V AC sockets for connecting your devices.
- Battery Terminals (12V DC): Connect to an external 12V DC battery. Ensure correct polarity.
- AC Input (230V): Connects the inverter to the mains power supply for charging the battery and providing power in UPS mode.
- Olufẹ itutu: Dissipates heat generated during operation.
- Opin Iyika monamona: Provides protection against overcurrent.
4. Eto
Follow these steps to set up your Rebel POWER-1000 UPS Inverter:
- Ṣii silẹ: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
- Ibi: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
- Asopọ batiri:
- Rii daju pe inverter ti wa ni pipa.
- Sopọ awọn pupa okun batiri si okun batiri naa rere (+) terminal of your 12V DC battery.
- Sopọ awọn dudu okun batiri si okun batiri naa odi (-) terminal of your 12V DC battery.
- Tighten all connections securely to prevent arcing.
- Asopọ Mais AC: Plug the inverter's AC input cable into a standard 230V AC wall outlet.
- Asopọmọra ẹrọ: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.
5. Awọn ilana Iṣiṣẹ
The Rebel POWER-1000 operates in three main modes:
- UPS Mode (Emergency Power Supply): When connected to mains power, the inverter charges the external battery and simultaneously supplies power to connected devices. In case of a power outage, it automatically switches to battery power within <4 ms, providing uninterrupted power.
- Rectifier Mode (Battery Charger): When connected to mains power without any load, the inverter functions as a battery charger, replenishing the external battery.
- Ipo Iyipada: When not connected to mains power, the inverter converts 12V DC battery power into 230V AC pure sine wave power for your connected devices.
Bíbẹ̀rẹ̀ Inverter:
- Ensure all connections (battery, AC input, loads) are secure.
- Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
- The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.
Alaye Ifihan LED:
The clear LED display provides crucial information:
- Iṣagbewọle Voltage: Fi iyipo AC ti nwọle hantage lati awọn mains.
- O wujade Voltage: Displays the 230V AC output voltage.
- Batiri Voltage: Tọkasi lọwọlọwọ voltage ti batiri 12V ti a so pọ mọ.
- Ipele fifuye: Ṣe afihan ogoruntage of the inverter's capacity being used by connected devices.
- Ipo Iṣiṣẹ: Icons or indicators for mains power, battery power, charging, and fault conditions.
6. Itọju
Regular maintenance ensures optimal performance and longevity of your inverter:
- Ninu: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure the cooling fan and ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Ayewo Batiri: Regularly check battery terminals for corrosion and ensure connections are tight. If using a lead-acid battery, check electrolyte levels if applicable and top up with distilled water as needed (refer to battery manufacturer's instructions).
- Afẹfẹ: Always ensure the inverter has adequate ventilation. Do not place objects on top of the unit or block its air vents.
- Ibi ipamọ: If storing the inverter for an extended period, disconnect it from both mains power and the battery. Store in a cool, dry place. For optimal battery health, fully charge the battery before storage and recharge it every 3-6 months.
7. Laasigbotitusita
If you encounter issues with your Rebel POWER-1000, refer to the following table:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Inverter ko tan | No battery connected or battery discharged; Main switch off; Blown circuit breaker. | Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel. |
| Ko si AC jade | Overload; Short circuit; Battery low; Inverter fault. | Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support. |
| Batiri ko ngba agbara | AC input not connected; AC input voltage too low/high; Battery fault. | Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty. |
| Apọju Ikilọ lori ifihan | Total power of connected devices exceeds 700 W. | Disconnect some devices to reduce the load below 700 W. |
| Unit is unusually hot | Blocked ventilation; Excessive load; High ambient temperature. | Ensure vents are clear; Reduce load; Move unit to a cooler environment. |
If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.
8. Awọn pato
Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Ti won won Agbara | 700 W (1000 VA) |
| Batiri Iru | 12 V DC |
| Max Batiri Voltage | 15 V DC |
| Iṣagbewọle Voltage Ibiti | 190 - 260 V AC |
| Igbohunsafẹfẹ Input | 45 - 60 Hz |
| O wujade Voltage (AC) | 230 V AC +/-5% (Inverter: 230 V AC +/-3%) |
| Igbohunsafẹfẹ Ijade | 50/60 Hz +/-0.5 Hz |
| Iwajade Waveform | Wave Sine Sure |
| Agbara idawọle | >= 85% (DC to AC) |
| Ngba agbara Batiri Lọwọlọwọ | Max. 10 A. |
| Aba agbara Batiri | 50-200 Ah (suggested: 55 Ah) |
| Ifoju Ngba Aago | 4-14 hours (dependent on battery capacity) |
| Yipada Time | =<4 ms |
| Awọn aabo | Overload, Short Circuit, Over/Under Voltage |
| Awọn iwọn otutu ti nṣiṣẹ | 0-40°C |
| Ọriniinitutu ti nṣiṣẹ | 10 - 90% |
| Awọn iwọn (L x W x H) | 336 x 143 x 178 mm |
| Iwọn | 4.3 kg |
9. Atilẹyin ọja ati Support
The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.