1. Ifihan
The AC Infinity pH Meter Kit (Model AC-PHM3) is a digital water quality meter designed for precise measurement of water's acidity, alkalinity, and temperature. This device is essential for optimizing water quality in various applications, including gardening, hydroponics, aquariums, swimming pools, and homebrewing. Its highly responsive sensor probe, featuring a lithium glass membrane, provides instant pH readings with an accuracy of ±0.1 pH.
The meter is built for durability with an IP-67 rating, ensuring protection against moisture, dust, and sand. A sensor shield further safeguards the probe. The kit includes 4.00 pH and 7.00 pH calibration solutions to maintain consistent accuracy and support proper probe storage.
2. Package Awọn akoonu
Verify that all items are present in your AC Infinity pH Meter Kit:
- AC Infinity pH Meter (Model AC-PHM3)
- 4.00 pH Calibration Solution
- 7.00 pH Calibration Solution

Image 2.1: The AC Infinity pH Meter Kit, showcasing the meter, calibration solutions, and its protective storage case.
3. Awọn ẹya Ọja
- Advanced Water Testing: Measures acidity, alkalinity, and temperature.
- Lithium Glass Membrane Sensor: Provides instant and accurate pH readings.
- Lab-Grade Precision: ±0.1 pH accuracy with included calibration solutions.
- Greater Durability: IP-67 rated for protection against water, dust, and sand.
- Sensor Shield: Protects the probe when not in use.

Image 3.1: Detail of the pH meter's lithium glass membrane sensor, highlighting its role in advanced water testing.

Image 3.2: The pH meter's digital display, illustrating a precise 4.00 pH reading and temperature, indicative of its accuracy.

Image 3.3: The pH meter partially submerged in water, emphasizing its IP67 rating and robust design for challenging environments.
4. Eto ati odiwọn
For accurate readings, the pH meter must be calibrated before first use and regularly thereafter. The kit includes 4.00 pH and 7.00 pH calibration solutions.
4.1 Igbaradi akọkọ
- Yọ ideri aabo kuro lati elekiturodu.
- Wẹ elekiturodu pẹlu omi ti a ti pọn tabi ti a ti pọn.
- Gently blot dry with a clean tissue. Do not rub.
4.2 Ilana isọdọtun
- Tan mita pH naa.
- Immerse the electrode into the 7.00 pH calibration solution. Ensure the electrode is fully submerged.
- Press and hold the CAL button until the display shows 'CAL' or begins flashing. The meter will automatically recognize the solution and calibrate. Wait for the reading to stabilize.
- Fi omi ṣan awọn elekiturodu pẹlu distilled omi ati ki o nù gbẹ.
- Immerse the electrode into the 4.00 pH calibration solution.
- Press and hold the CAL button again. The meter will calibrate to the 4.00 pH solution. Wait for the reading to stabilize.
- Fi omi ṣan awọn elekiturodu pẹlu distilled omi ati ki o nù gbẹ.
- Your meter is now calibrated and ready for use.
Akiyesi: Regular calibration (e.g., every few weeks or before critical measurements) is crucial for maintaining accuracy, especially with frequent use or after long periods of storage.
5. Isẹ
5.1 Gbigba Idiwon
- Ensure the meter is calibrated as described in Section 4.
- Remove the protective cap and rinse the electrode with distilled water.
- Fi elekitirodu sinu sample solution you wish to test. Ensure the electrode is fully submerged.
- Gently stir the meter in the solution to remove any air bubbles.
- Wait for the reading on the display to stabilize. This typically takes a few seconds. The display will show both pH and temperature.
- Record your measurement.
- After use, rinse the electrode thoroughly with distilled water.

Image 5.1: The pH meter in operation, measuring the pH and temperature of a liquid sample in a laboratory beaker.
6. Itọju ati Ipamọ
Proper maintenance and storage are crucial for extending the lifespan and accuracy of your pH meter.
6.1 Nu elekitirodu naa mọ
- Fi omi tí a ti yọ tàbí tí a ti yọ kúrò nínú rẹ̀ fọ elekitirodu náà nígbà gbogbo kí ó tó di àti lẹ́yìn lílò kọ̀ọ̀kan.
- If the electrode becomes dirty or contaminated, gently clean it with a soft brush or cotton swab and a mild cleaning solution (e.g., diluted detergent or specialized electrode cleaning solution). Rinse thoroughly afterward.
- Avoid touching the glass membrane directly, as oils from your skin can affect its performance.
6.2 Ibi ipamọ
- The pH electrode should always be stored in a storage solution or 4.00 pH calibration solution. Never store it dry or in distilled water, as this can damage the glass membrane.
- Ensure the protective cap is securely placed over the electrode when not in use to prevent drying out and physical damage.
- Tọ́jú mita náà sí ibi tí ó tutù tí ó sì gbẹ, kúrò níbi tí oòrùn kò ti lè tàn án tàbí ibi tí ó gbóná jù.
7. Laasigbotitusita
- Àwọn Ìkà tí kò péye tàbí tí kò dúró ṣinṣin:
- Ensure the meter is properly calibrated. Re-calibrate if necessary.
- Check if the electrode is clean and free from debris. Clean as per Section 6.1.
- Verify that the electrode is fully submerged in the solution.
- Rii daju pe sampiwọn otutu le wa laarin iwọn iṣiṣẹ ti mita naa.
- Mita ko tan:
- Ṣàyẹ̀wò ipele batiri. Rọpo awọn batiri ti o ba kere.
- Ensure the battery compartment is properly sealed.
- Àkókò Ìdáhùn Díẹ̀díẹ̀:
- The electrode may be dry or contaminated. Re-hydrate by soaking in storage solution for a few hours, then re-calibrate.
- The electrode may be nearing the end of its lifespan.
- Ikuna Iṣatunṣe:
- Ensure you are using fresh, unexpired calibration solutions.
- Verify the electrode is clean and properly submerged.
- If issues persist, the electrode may be damaged or worn out.
8. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Awoṣe | AC-PHM3 |
| Sensọ Iru | pH, Temperature |
| Iwadii | Lithium Glass Membrane |
| pH Yiye | ± 0.1 pH |
| Calibration Solutions Included | 4.00 pH, 7.00 pH |
| IP Rating | IP67 |
| Package Mefa | 11.14 x 7.99 x 3.07 inches |
| Iwọn Nkan | 1.92 iwon |

Image 8.1: Visual representation of the pH meter's dimensions and the two types of calibration solutions provided.
9. Atilẹyin ọja ati Support
AC Infinity products are designed for reliability and performance. For warranty information, technical support, or assistance with your AC Infinity pH Meter Kit (Model AC-PHM3), please visit the official AC Infinity website or contact their customer service department. Ensure you have your product model number (AC-PHM3) and purchase details available when seeking support.