Black+Decker BXGND6300E

BLACK+DECKER BXGND6300E Diesel Generator

Itọsọna olumulo

Model: BXGND6300E

1. Ifihan

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your BLACK+DECKER BXGND6300E Diesel Generator. This 6300W diesel generator features an Automatic Transfer Switch (ATS) for automatic power activation during outages and is suitable for solar system support, providing stable power with Automatic Voltage Regulation (AVR).

2. Alaye Aabo

IKILỌ: Ikuna lati tẹle awọn ilana aabo wọnyi le ja si ipalara nla tabi iku.

  • Èéfín Èéfín: Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous gas. Never operate the generator indoors or in enclosed spaces. Ensure adequate ventilation when operating outdoors.
  • Ibalẹ itanna: Do not operate the generator in wet conditions. Ensure all electrical connections are secure and properly grounded. Never touch live electrical parts.
  • Ewu ina: Diesel fuel is flammable. Always refuel in a well-ventilated area with the engine off and cool. Do not smoke or allow open flames near the generator. Store fuel in approved containers.
  • Awọn oju gbigbona: The generator engine and muffler become very hot during operation and remain hot for a period after shutdown. Avoid touching hot surfaces to prevent burns.
  • Awọn ẹya gbigbe: Keep hands, feet, and clothing away from moving parts such as the fan and belts.
  • Awọn ọmọde ati awọn ohun ọsin: Jeki awọn ọmọde ati awọn ohun ọsin kuro ni monomono ni gbogbo igba.

3. Ọja Ipariview ati irinše

The BLACK+DECKER BXGND6300E is a robust diesel generator designed for reliable power supply. Familiarize yourself with its main components for safe operation and maintenance.

BLACK+DECKER BXGND6300E Diesel Generator with two workers

Nọmba 3.1: Lapapọ view of the BLACK+DECKER BXGND6300E Diesel Generator.

Control panel of the BLACK+DECKER BXGND6300E Diesel Generator

Figure 3.2: Close-up of the generator's control panel, showing the display, start/stop buttons, key switch, and power outlets.

Engine compartment of the BLACK+DECKER BXGND6300E Diesel Generator

Figure 3.3: Engine compartment with the maintenance door open, showing the engine, oil fill, and fuel system components.

4. Eto

Before starting the generator, ensure it is properly set up according to these instructions.

4.1 Ṣiṣii ati Gbe

  • Fara yọ monomono kuro ninu apoti rẹ.
  • Place the generator on a firm, level surface outdoors, away from windows, doors, and vents. Ensure at least 1 meter (3 feet) of clear space around the generator for proper ventilation.

4.2 Epo kikun

The generator requires engine oil for operation. Use Motul 15W40 mineral oil.

  1. Open the maintenance cover on the side of the generator.
  2. Unscrew awọn epo kikun fila.
  3. Using a funnel, carefully fill the oil reservoir with the recommended oil until it reaches the upper mark on the dipstick. Do not overfill.
  4. Re-insert the dipstick without screwing it in to check the oil level. The oil level should be at the upper mark.
  5. Once filled, screw the oil filler cap back on securely and close the maintenance cover.

4.3 epo kikun

The generator operates on diesel fuel. Ensure you use clean, fresh diesel fuel.

  1. Unscrew the fuel tank cap located on the top of the generator.
  2. Using a clean funnel, carefully pour diesel fuel into the tank. Do not overfill; leave some space for expansion.
  3. Wipe up any spilled fuel immediately and thoroughly before proceeding.
  4. Paarọ ideri ojò epo ni aabo.

4.4 Purging the Fuel Circuit

Before the first start or after running out of fuel, the fuel circuit may need to be purged of air.

  1. Locate the fuel line connection to the fuel pump.
  2. Using two pliers, gently pinch the fuel tube and open the clamp to release the connection.
  3. Allow fuel to flow out until it is free of air bubbles, indicating the tube is full of fuel.
  4. Reconnect the fuel tube and secure the clamp.

5. Awọn ilana Iṣiṣẹ

Follow these steps to start and operate your generator safely.

5.1 Bibẹrẹ monomono

  1. Ensure the generator is on a level surface and all connections are secure.
  2. Insert the key into the ignition switch on the control panel.
  3. Turn the key to the 'START' position. The display screen will illuminate.
  4. Press the green 'START' button on the control panel. After a brief countdown, the generator will begin to crank and start.
  5. Allow the generator to run for a few minutes to warm up before connecting any electrical loads.

5.2 Idaduro monomono

  1. Ge asopọ gbogbo awọn ẹru itanna lati monomono.
  2. Press the red 'STOP' button on the control panel. After a brief countdown, the generator will shut down.
  3. Turn the ignition key to the 'OFF' position and remove it for security.

5.3 Automatic Transfer Switch (ATS) Functionality

The ATS system allows the generator to automatically activate during a power outage.

  • Ensure the ATS switch on the control panel is set to 'AUTO'.
  • When the main power supply fails, the ATS system will detect the outage and automatically start the generator.
  • Once main power is restored, the ATS system will automatically shut down the generator and transfer the load back to the main supply.

5.4 Solar System Support

This generator can function as a backup for photovoltaic installations, automatically switching to charge batteries when the main electrical grid is unavailable.

6. Itọju

Itọju deedee ṣe pataki fun igba pipẹ ati iṣẹ ṣiṣe ti ẹrọ ina rẹ.

6.1 Daily Checks (Before Each Use)

  • Ṣayẹwo ipele epo engine.
  • Ṣayẹwo ipele epo.
  • Inspect for any visible leaks (oil, fuel).
  • Ṣàyẹ̀wò àlẹ̀mọ́ afẹ́fẹ́ fún ìmọ́tótó.

6.2 Every 50 Hours or Monthly

  • Yi epo engine pada.
  • Nu tabi ropo air àlẹmọ.
  • Inspect battery terminals and cables.

6.3 Every 200 Hours or Annually

  • Rọpo idana àlẹmọ.
  • Inspect and adjust valve clearance (professional service recommended).
  • Clean fuel tank and fuel lines.
  • Ṣayẹwo gbogbo fasteners fun wiwọ.

7. Laasigbotitusita

Tọkasi apakan yii fun awọn ọran ti o wọpọ ati awọn ojutu wọn.

IsoroOwun to le FaOjutu
monomono yoo ko bẹrẹKo si epo
Ipele epo kekere
Batiri ti gba silẹ
Fuel system air-locked
Fi epo diesel kun
Fi epo ẹrọ kun
Gba agbara tabi ropo batiri
Purge fuel system (Section 4.4)
Engine starts but stops quicklyIpele epo kekere
Ajọ idana ti o ti di
Apọju
Ṣayẹwo ki o si fi epo kun
Rọpo idana àlẹmọ
Reduce electrical load
Ko si iṣelọpọ agbaraCircuit fifọ tripped
Apọju
Asopọmọra aṣiṣe
Atunto Circuit fifọ
Din fifuye
Ṣayẹwo gbogbo awọn asopọ itanna
Ẹfin ti o pọjuWrong oil type/level
Àlẹmọ afẹfẹ sé
Aṣiṣe ẹrọ
Use correct oil, check level
Mọ / ropo air àlẹmọ
Olubasọrọ iṣẹ Onimọn

8. Awọn pato

Key technical specifications for the BLACK+DECKER BXGND6300E Diesel Generator.

Dimensions of the BLACK+DECKER BXGND6300E Diesel Generator

Figure 8.1: Generator dimensions: 92 cm (length) x 52 cm (width) x 76 cm (height).

  • Nọmba awoṣe: BXGND6300E
  • Power Output (Max): 6300 Wattis
  • Power Output (Nominal): 6000 Wattis
  • Voltage: 230 Volts
  • Iru epo: Diesel
  • Enjini: 498cc, 4-stroke diesel
  • Agbara Epo epo: 12 liters
  • Autonomy (50% load): Titi di wakati 10
  • Ipele Ariwo: 72 dB (at 7 meters)
  • Awọn iwọn (L x W x H): 92 x 52 x 76 cm
  • Ìwúwo: 152 kg
  • Batiri: 1 x 12V (included, Lithium-Phosphate type)
  • Alternator: 100% Copper winding, AVR (Automatic Voltage Ilana)

9. Official Product Video: Setup and Operation

Watch this video for a visual guide on how to set up and operate your BLACK+DECKER BXGND6300E Diesel Generator, including oil and fuel filling, fuel circuit purging, and starting/stopping procedures.

Video 9.1: Step-by-step guide on preparing and starting the generator.

10. Atilẹyin ọja ati Support

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Black+Decker webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira.

Awọn iwe aṣẹ ti o jọmọ - BXGND6300E

Ṣaajuview Black+Decker BXGND6300E/BXGND7900E Generator User Manual
User manual for Black+Decker generators models BXGND6300E and BXGND7900E, including safety instructions, operation, maintenance, and technical specifications.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Ẹ̀rọ Amúṣiṣẹ́ BLACK+DECKER - Ẹ̀rọ BXGNP
Ìwé ìtọ́ni tó péye fún àwọn ẹ̀rọ amúṣẹ́dá BLACK+DECKER tó ṣeé gbé kiri, tó ní ààbò, ìṣiṣẹ́, ìtọ́jú, àti àwọn ìlànà ìmọ̀ ẹ̀rọ fún àwọn àwòṣe BXGNP2200E, BXGNP3000E, BXGNP5510E, BXGNP6510E, àti BXGNP7510E.
Ṣaajuview BLACK+DECKER Ọja Atilẹyin ọja, Atunlo, ati Alaye Iṣẹ
Itọsọna okeerẹ si BLACK+DECKER's atilẹyin ọja to lopin ọdun meji, eto atunlo batiri (RBRC), alaye ẹya ara ẹrọ, ati awọn alaye ile-iṣẹ iṣẹ fun awọn ọja olumulo.
Ṣaajuview BLACK+DECKER PPRH5B Portable Power Station Instruction Manual
This instruction manual for the BLACK+DECKER PPRH5B Portable Power Station provides comprehensive details on its features, operation, safety guidelines, and troubleshooting for jump-starting vehicles, inflating tires with its air compressor, and providing portable AC/DC/USB power.
Ṣaajuview Àwọn Ìbéèrè àti Àtìlẹ́yìn fún Àpótí Ẹ̀rọ Amúlétutù Dúdú+DECKER
Wa idahun si awọn ibeere ti a maa n beere nigbagbogbo ati alaye atilẹyin fun BLACK+DECKER Bagless Corded HEPA Filter Carpet Vacuum, awoṣe BDXCAV217G.
Ṣaajuview DÚDÙ+DECKER 450 AMP Ìbẹ̀rẹ̀ SLIM JUMP PẸ̀LÚ ÌWÉ ÌTỌ́NI COMPRESSOR
Ìwé ìtọ́ni tó péye fún BLACK+DECKER 450 AMP ÌBÁMẸ́RÌN SLIM JUMP PẸ̀LÚ COMPRESSOR, ó ṣàlàyé bí a ṣe fẹ́ lò ó, àwọn ìtọ́ni ààbò, ìtọ́jú, gbígbà agbára, ìṣiṣẹ́, àti ìṣòro fún àwọn ọkọ̀ ayọ́kẹ́lẹ́ tí ń bẹ̀rẹ̀ àti lílo compressor afẹ́fẹ́ tí a ti so pọ̀ mọ́ra.