Ọrọ Iṣaaju
Thank you for choosing the Inkbird ITC-C216T Thermostat. This device is a versatile plug-and-play temperature controller designed for precise temperature management in a wide range of applications. It features three control modes: temperature, cycle time, and countdown, along with safety features like high/low temperature alarms and a child lock. This manual will guide you through the setup, operation, and maintenance of your thermostat to ensure optimal performance and safe use.
Alaye Aabo
- Ensure the thermostat is connected to a grounded power outlet.
- Do not exceed the maximum load capacity of 10A, 220V AC (2200W).
- Keep the device away from water, except for the IP67 rated probe.
- Do not attempt to disassemble or repair the unit yourself. Contact customer support if issues arise.
- Yọọ ẹrọ naa nigba gbogbo ṣaaju ṣiṣe mimọ tabi ṣiṣe itọju.
Ọja Pariview
Awọn eroja

Aworan: Detailed diagram of the Inkbird ITC-C216T thermostat with labeled components.
- LCD with White Backlight: Displays current and set temperatures/times.
- Operational Buttons: MODE, UP, SET, DOWN for navigation and setting adjustments.
- Abajade: Max 10A (2200W at 220Vac) for connecting heating or cooling devices.
- Iwadi otutu: 2m/79in long, IP67 waterproof for accurate temperature detection.
- Iṣawọle: 100~240Vac 50/60Hz max 10A.
- Aami alapapo: Indicates heating operation.
- Cooling Icon: Indicates cooling operation.
- Timing Icon: Indicates timing function is active.
- Aami Titii Ọmọde: Indicates child lock is engaged.
- BERE: Displays start temperature or time.
- DURO: Displays stop temperature or time.
Key Awọn ẹya ara ẹrọ

Aworan: The Inkbird ITC-C216T thermostat showcasing awọn ẹya ara ẹrọ akọkọ rẹ.
- Ifihan LCD Backlit: Easy to read current and set values, even in low light.
- Three Control Modes: Temperature, Cycle Time, and Countdown.
- Ibi iwọn otutu ti o tobi: Controls temperatures from -40°C to 100°C.
- Awọn itaniji iwọn otutu giga/kekere: Customizable alarm values with an option to mute the buzzer.
- Iṣatunṣe iwọn otutu: Allows for fine-tuning temperature readings.
- Cooling Delay: Protects cooling equipment from short cycling.
- Titiipa ọmọ: Idilọwọ awọn ayipada lairotẹlẹ si awọn eto.
- Iṣẹ Iranti: Retains all settings after a power interruption.
- Ìwádìí Omi IP67: Suitable for use in soil or submerged in water.
Ṣeto
- Yọọ kuro: Carefully remove the thermostat and its components from the packaging.
- Wọle: Insert the thermostat into a standard 220V AC grounded power outlet. The LCD display will light up.
- So ẹrọ pọ: Plug your heating or cooling device (e.g., heater, fan, refrigerator) into the output socket of the thermostat.
- Iwadi ipo: Place the waterproof temperature probe in the environment where temperature control is needed (e.g., terrarium, water, soil). Ensure the probe is securely positioned and not directly exposed to heating elements or strong air currents that could affect readings.
Awọn ọna ṣiṣe
The ITC-C216T thermostat supports three main control modes: Temperature Mode, Cycle Time Mode, and Countdown Mode. Please note that Temperature Mode and Timing functions cannot be used simultaneously.
1. Temperature Mode

Aworan: Visual representation of the thermostat's cooling and heating functions.
In Temperature Mode, the thermostat automatically controls your connected device (heater or cooler) to maintain a desired temperature range. The device will operate in heating or cooling mode based on your set START and STOP temperatures.
- Tẹ awọn MODE button repeatedly until the display shows the temperature mode (usually indicated by a thermometer icon).
- Tẹ SET to enter setting mode. The START temperature will flash. Use the UP ati SILE buttons to adjust the desired START temperature.
- Tẹ SET again to confirm and move to the STOP temperature. Adjust the STOP temperature using UP ati SILE.
- Tẹ SET one more time to save the settings and exit.
- If START temperature is lower than STOP temperature, the thermostat operates in alapapo mode.
- If START temperature is higher than STOP temperature, the thermostat operates in itutu mode.
2. Cycle Time Mode (P01)

Aworan: Diagram explaining the Cycle Time Mode (P01) operation.
This mode allows you to set a repeating ON/OFF cycle for your connected device. The time range is 0 to 99 hours and 59 minutes.
- Tẹ MODE until P01 is displayed.
- Tẹ SET. The ON time will flash. Adjust using UP/SILE.
- Tẹ SET. The OFF time will flash. Adjust using UP/SILE.
- Tẹ SET to save and exit. The device will now cycle ON and OFF according to your settings.
3. Countdown Mode (P02, P03, P04)
The Countdown Mode offers three sub-modes for specific timed operations:
- P02: Countdown ON

Aworan: Diagram explaining the Countdown ON Mode (P02).
The device will turn ON after the set countdown period. - P03: Countdown OFF

Aworan: Diagram explaining the Countdown OFF Mode (P03).
The device will turn OFF after the set countdown period. - P04: Countdown ON & OFF

Aworan: Diagram explaining the Countdown ON&OFF Mode (P04).
The device will turn ON after the first countdown, then turn OFF after a second countdown.
To set any Countdown Mode:
- Tẹ MODE until P02, P03, or P04 is displayed.
- Tẹ SET. The countdown time(s) will flash. Adjust using UP/SILE.
- Tẹ SET lati fipamọ ati jade.
To ti ni ilọsiwaju Eto
Iṣatunṣe iwọn otutu (CA)

Aworan: Thermostat screen showing temperature calibration setting.
If you find that the temperature reading is inaccurate compared to a known reference thermometer, you can calibrate the device:
- With the device powered on, press and hold the SET button for approximately 3 seconds to enter the parameter settings.
- Lo awọn UP/SILE buttons to navigate to the 'CA' (Calibration) setting.
- Tẹ SET, lẹhinna lo UP/SILE to adjust the calibration value (e.g., +0.5°C or -0.5°C).
- Tẹ SET lati jẹrisi ati jade.
Cooling Delay (Pt)

Aworan: Thermostat screen showing refrigeration delay setting.
The cooling delay function prevents rapid cycling of cooling equipment, which can extend its lifespan.
- Enter parameter settings (press and hold SET fun 3 aaya).
- Navigate to 'Pt' (Cooling Delay).
- Adjust the delay time in minutes using UP/SILE.
- Tẹ SET lati jẹrisi ati jade.
High/Low Temperature Alarms (AH/AL)

Aworan: Thermostat screen showing high temperature alarm with mute option.
Set custom high (AH) and low (AL) temperature alarm values. If the detected temperature exceeds these limits, an audible alarm will sound.
- Enter parameter settings.
- Navigate to 'AH' (High Alarm) or 'AL' (Low Alarm).
- Adjust the alarm temperature using UP/SILE.
- Tẹ SET lati jẹrisi.
- To mute the buzzer, press any button when the alarm sounds.
Titiipa ọmọ

Aworan: Thermostat displaying the child lock icon.
Láti dènà àwọn ìyípadà àìròtẹ́lẹ̀ sí àwọn ètò, mu titiipa ọmọ náà ṣiṣẹ́:
- Tẹ mọlẹ UP ati SILE buttons simultaneously for approximately 3 seconds. The child lock icon will appear on the display.
- Repeat the action to unlock the device.
Iranti iṣẹ & Atunto Factory
- Iṣẹ Iranti: The thermostat automatically saves all your settings. In case of a power outage, the device will resume operation with the last saved settings once power is restored.
- Idapada si Bose wa tele: To restore the device to its default factory settings, consult the full user manual or contact Inkbird support for specific instructions.
Awọn ohun elo

Aworan: Diverse applications of the Inkbird ITC-C216T thermostat.
The Inkbird ITC-C216T thermostat is suitable for a wide range of temperature control needs, including but not limited to:
- Reptile Terrariums and Aquariums
- Greenhouses and Plant Propagation
- Incubators for Eggs
- Home Brewing and Fermentation
- Controlling Freezers and Refrigerators
- Managing Heating Mats and other Home Appliances
Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awoṣe | ITC-C216T |
| Voltage | 220V AC |
| Iṣajade ti o pọju | 10A / 2200W |
| Iwọn iṣakoso iwọn otutu | -40°C si 100°C (-40°F si 212°F) |
| Ibiti akoko | 0 to 99 hours 59 minutes |
| Iwadi Iru | IP67 mabomire |
| Gigun ibere | 2 mita (79 inches) |
| Ohun elo | Acrylonitrile Butadiene Styrene (ABS) |
| Awọn iwọn | 8.8 x 8.9 x 13.7 cm |
| Iwọn | 250 g |
| Adarí Iru | Bọtini |
Laasigbotitusita
If you encounter issues with your Inkbird ITC-C216T thermostat, please refer to the following common solutions:
- Ifihan Ko Imọlẹ: Ensure the thermostat is securely plugged into a live power outlet. Check the power supply.
- Kika iwọn otutu ti ko pe: Verify the probe is correctly placed and not damaged. Perform a temperature calibration (refer to Advanced Settings).
- Ohun elo Ko Titan/Pa: Check if the connected heating/cooling device is functioning correctly. Ensure the thermostat is in the correct operating mode (Temperature, Cycle Time, or Countdown) and that settings are properly configured. Verify the child lock is not active.
- Alarm Sounds Continuously: Check the high/low alarm settings (AH/AL) and the current temperature. Adjust alarm values if necessary or mute the buzzer by pressing any button.
- Awọn Eto ti ko Fipamọ: The device has a memory function. If settings are not retained, try a factory reset (consult full manual) or contact support.
For more detailed troubleshooting or persistent issues, please contact Inkbird customer support.
Itoju
- Ninu: Disconnect the thermostat from power before cleaning. Wipe the unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the main unit in water.
- Itọju Iwadii: Regularly inspect the temperature probe for any signs of damage. Clean the probe gently if it accumulates debris, especially if used in water or soil.
- Ibi ipamọ: If storing the device for an extended period, ensure it is clean and dry. Store in a cool, dry place away from direct sunlight.
Atilẹyin ọja ati Support
Inkbird products are designed for reliability and performance. This product comes with a standard manufacturer's warranty. For specific warranty terms, registration, or technical support, please visit the official Inkbird webojula tabi kan si wọn onibara iṣẹ taara.
O le wa alaye diẹ sii ati awọn orisun atilẹyin nipasẹ lilo si Inkbird Store on Amazon.