Einhell TC-EH 250

Ìwé Ìtọ́ni fún Ìgbéga Okùn Einhell TC-EH 250

Model: TC-EH 250 | Item Number: 2255130

1. Ifihan ati Alaye Aabo

This manual provides essential information for the safe and efficient operation, setup, and maintenance of your Einhell Cable Hoist TC-EH 250. Please read all instructions carefully before using the device to ensure personal safety and prevent damage to the equipment.

Awọn Itọsọna Aabo Gbogbogbo:

  • Always ensure the hoist is securely mounted before operation.
  • Maṣe kọja agbara fifuye ti o pọju.
  • Pa ọwọ ati awọn aṣọ alaimuṣinṣin kuro lati awọn ẹya gbigbe.
  • Regularly inspect the wire rope, hooks, and safety mechanisms for wear or damage.
  • In case of malfunction, immediately activate the emergency stop switch and disconnect power.

2. Ọja Ipariview

The Einhell Cable Hoist TC-EH 250 is designed for lifting loads up to 250 kg using a robust wire rope and pulley system. It features a powerful motor, safety mechanisms, and a user-friendly control console.

Awọn ẹya pataki:

  • Lifts loads up to 250 kg with a pulley and load hook.
  • Maximum lifting height of 5.7 meters with pulley.
  • Equipped with a 12-meter twist-free wire rope (3 mm diameter).
  • 500-watt motor with thermal switch for overload protection.
  • Emergency stop switch on the control console for immediate shutdown.
  • Automatic brake system to secure the load in any position.
  • Automatic end stop mechanism to prevent overturning.
Einhell Cable Hoist TC-EH 250 mounted on a beam

Nọmba 1: Einhell Cable Hoist TC-EH 250. This image shows the red and silver electric hoist securely mounted on a horizontal metal beam. The robust red casing covers the motor and cable drum, with the steel wire rope visible. The control console cable extends from the unit, highlighting the compact design and mounting mechanism of the hoist.

3. Eto

Proper setup is crucial for the safe operation of the cable hoist.

Gbigbe Hoist:

  1. Select a sturdy, horizontal beam or support structure capable of safely bearing the hoist's weight plus the maximum intended load.
  2. Attach the hoist securely to the beam using appropriate mounting hardware (not always included, refer to product packaging). Ensure all bolts and fasteners are tightened to the manufacturer's specifications.
  3. Verify that the hoist is level and stable, with no wobbling or movement.

Wire Rope and Pulley Installation:

  1. The hoist comes with a 12-meter twist-free wire rope pre-installed on the drum.
  2. For single-line operation (max 125 kg), attach the load hook directly to the end of the wire rope.
  3. For double-line operation (max 250 kg), use the included pulley with load hook. Thread the wire rope through the pulley and secure the end of the rope to the hoist body as per the diagram in the full manual. Ensure the load hook's safety bar is functional.

Asopọmọra itanna:

  • Connect the hoist to a suitable power supply (e.g., 230V, 50Hz) via a grounded outlet.
  • Ensure the power supply matches the specifications on the hoist's rating plate.

4. Awọn ilana Iṣiṣẹ

Familiarize yourself with the control console and safety features before operating the hoist.

Konsolo Iṣakoso:

  • The control console typically features 'Up' and 'Down' buttons for lifting and lowering, and an 'Emergency Stop' button.
  • Press and hold the 'Up' button to lift the load. Release to stop.
  • Press and hold the 'Down' button to lower the load. Release to stop.

Lifting Operations:

  1. Attach the load securely to the load hook, ensuring the safety bar is closed.
  2. Ensure the load is balanced and will not swing excessively during lifting.
  3. Slowly lift the load, observing its stability.
  4. The automatic brake will engage when the 'Up' or 'Down' button is released, securing the load in position.
  5. The automatic end stop will prevent the hook from traveling too high or too low, stopping the motor automatically.

Iduro Pajawiri:

  • In an emergency or if an unsafe condition occurs, press the red 'Emergency Stop' button on the control console. This will immediately cut power to the motor and engage the brake.
  • To reset the emergency stop, twist the button clockwise and pull it out.

5. Itọju

Itọju deedee n rii daju pe o pẹ to ati pe o ni aabo lati ṣiṣẹ lori ohun elo gbigbe rẹ.

Lojoojumọ/Ṣaaju Lilo:

  • Inspect the wire rope for kinks, fraying, corrosion, or broken strands. Replace if any damage is found.
  • Check the load hook and safety bar for deformation or damage.
  • Verify that the mounting bolts are tight and the hoist is secure.
  • Test the emergency stop function.

Itọju igbakọọkan:

  • Clean the hoist exterior with a damp asọ. Maṣe lo awọn kẹmika ti o lewu tabi awọn olomi.
  • Check electrical cables for damage.
  • The motor is equipped with a thermal switch that will automatically shut down the motor if it overheats. Allow the motor to cool down before resuming operation.

6. Laasigbotitusita

Abala yii n ṣalaye awọn ọran ti o wọpọ ti o le ba pade.

Problem: Hoist does not operate.

  • Owun to le fa: Ipese agbara oro.
    Ojutu: Check if the hoist is properly plugged in and the power outlet is functional.
  • Owun to le fa: Emergency stop button is engaged.
    Ojutu: Reset the emergency stop button by twisting it clockwise and pulling it out.
  • Owun to le fa: Motor thermal switch activated due to overheating.
    Ojutu: Allow the motor to cool down for at least 15-20 minutes. Reduce load or operating time to prevent recurrence.

Problem: Load stops unexpectedly during operation.

  • Owun to le fa: Automatic end stop activated.
    Ojutu: The hoist has reached its upper or lower limit. Operate in the opposite direction.
  • Owun to le fa: Apọju.
    Ojutu: Reduce the load to within the specified capacity. The thermal switch may have activated.

7. Awọn pato

Ẹya ara ẹrọSipesifikesonu
AwoṣeTC-EH 250
Nọmba Awoṣe Nkan2255130
Agbara mọto500 W
Max Load (Single Line)125 kg
Max Load (Double Line with Pulley)250 kg
Max Lift Height (Single Line)11.5 m
Max Lift Height (Double Line with Pulley)5.7 m
Waya Okun Ipari12 m
Opin Ikun Waya3 mm
Ọja Mefa14.13 x 5.71 x 9.45 inches
Iwọn Ọja22.05 iwon
OlupeseEinhell

8. Atilẹyin ọja ati Support

For warranty information, technical support, or spare parts, please contact your retailer or the official Einhell customer service. Keep your purchase receipt and product model number (TC-EH 250) and item number (2255130) readily available when contacting support.

Awọn iwe aṣẹ ti o jọmọ - TC-EH 250

Ṣaajuview Einhell TC-EH 250 Seilhebezug Bedienungsanleitung
Umfassende Bedienungsanleitung für den Einhell TC-EH 250 Seilhebezug. Enthält wichtige Sicherheitshinweise, technische Daten, Bedienungsanleitungen, Wartungshinweise und Entsorgungsinformationen für den sicheren und effizienten Einsatz Ihres Einhell Seilhebezugs.
Ṣaajuview Einhell TC-EH 250 Originalbetriebsanleitung
Die Originalbetriebsanleitung für den Einhell TC-EH 250 elektrischen Seilhebezug. Enthält umfassende Informationen zu Sicherheit, technischen Daten, Montage, Bedienung und Wartung.
Ṣaajuview Einhell TC-LW 1000 / TC-LW 2000 Handhebelseilzug Bedienungsanleitung
Umfassende Bedienungsanleitung für die Einhell TC-LW 1000 und TC-LW 2000 Handhebelseilzüge. Enthält Sicherheitshinweise, technische Daten, Bedienung, Wartung und Garantieinformationen.
Ṣaajuview Àwọn Ìlànà Ìṣiṣẹ́ Winch Okùn EINHELL BT-EH 250
Comprehensive operating instructions for the EINHELL BT-EH 250 Cable Winch, covering safety, assembly, operation, maintenance, and disposal. Learn how to safely and effectively use this electric cable hoist for lifting and lowering loads.
Ṣaajuview Einhell TC-MG 250 CE Multifunktionswerkzeug - Originalbetriebsanleitung
Umfassende Originalbetriebsanleitung für das Einhell TC-MG 250 CE Multifunktionswerkzeug. Enthält Sicherheitshinweise, technische Daten, Bedienungsanleitung, Wartung und Entsorgung.
Ṣaajuview Einhell TC-EH 1000 Elektrischer Seilhebezug Bedienungsanleitung
Offisielle Bedienungsanleitung für den Einhell TC-EH 1000 Elektrischen Seilhebezug. Enthält Sicherheitshinweise, technische Daten, Montage-, Bedienungs- und Wartungsanleitungen.