waveshare Modbus RTU Relay (D)

Ìwé Ìtọ́ni fún Ìgbékalẹ̀ Ìṣiṣẹ́ Waveshare Modbus RTU 8-Channel Relay Module (D)

Model: Modbus RTU Relay (D)

1. Ọja Ipariview

The Waveshare Industrial Modbus RTU 8-Channel Relay Module (D) is a robust and versatile device designed for industrial control and automation applications. It features 8 relay outputs and 8 digital inputs, communicating via the RS485 bus using the Modbus RTU protocol. This module incorporates multiple isolation protection circuits, including power isolation, magnetic isolation, and TVS diode protection, ensuring stable, reliable, and safe operation. Its rail-mounted ABS plastic enclosure facilitates easy installation in various industrial environments.

Waveshare Industrial Modbus RTU 8-Channel Relay Module (D)

Figure 1: Waveshare Industrial Modbus RTU 8-Channel Relay Module (D)

1.1. Ọja Video Loriview

Video 1: Modbus RTU Relay Series Overview. This video provides a general introduction to the Waveshare Modbus RTU relay series, highlighting key features and different versions available.

2. Package Awọn akoonu

Jọwọ rii daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:

  • Modbus RTU Relay (D) x1
  • Screwdriver x1
Package Contents of Modbus RTU Relay (D)

Nọmba 2: Awọn akoonu Package

3. Awọn ẹya ara ẹrọ ati awọn pato

The Modbus RTU 8-Channel Relay Module (D) offers a comprehensive set of features for reliable industrial control:

  • Configurable device address (1~255), allowing multiple devices to be cascaded on the RS485 bus.
  • Features flash-on, flash-off function, enabling temporary relay activation with automatic closure.
  • Onboard unibody power supply isolation provides stable isolated voltage, eliminating the need for an extra power supply for the isolated terminal.
  • Onboard unibody magnetic isolation ensures signal isolation, high reliability, strong anti-interference, and low power consumption.
  • Onboard resettable fuse and TVS (Transient Voltage Suppressor) effectively suppress surge voltage ati tionkojalo iwasoke voltage, providing over-current/over-voltage protection, lightning protection, and anti-electrostatic capabilities.
  • Onboard Optocoupler isolation prevents interference from high-voltage awọn iyika.
  • Adopts a dedicated relay driver chip with built-in flyback diode protection for stronger and more stable driving ability.
  • Supports passive and active digital input with bi-directional optocoupler isolation and built-in debouncing algorithm. The relay supports digital input linkage control or toggle control.
  • Reverse-proof circuit prevents accidental damage from incorrect power connection.
  • High quality relay with contact rating: ≤10A 250VAC/30VDC.
  • Rail-mounted ABS plastic enclosure for easy installation and safe use.
  • Multiple LEDs for indicating MCU status and signal transceiving status.
RS485 8-Ch Relay Module (D) Overview

Figure 3: RS485 8-Channel Relay Module (D) with key features highlighted.

3.1. Imọ ni pato

ParamitaIye
Ibi ti ina elekitiriki ti nwa7 ~ 36V
Ibaraẹnisọrọ InterfaceRS485
Ṣàyẹ̀wò4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000
Default Communication Format9600, N, 8, 1
Relay awọn ikanni8
Fọọmu olubasọrọ1KO 1NC
Olubasọrọ Rating≤10A 250VAC/30VDC
Input oni -nọmba8DI, 5~36V, passive / active input (NPN or PNP), built-in bi-directional optocoupler isolation
Ilana ibaraẹnisọrọStandard Modbus RTU protocol
RS485 adirẹsi1-255
LED IfiSTA: MCU indicator, keeps flashing when the MCU normally working
TXD: TX indicator, lights up when sending data
RXD: RX indicator, lights up when receiving data
Ọja Mefa6.89 x 3.54 x 1.57 inches; 13.05 iwon
Features At A Glance and Primary Function Diagram

Figure 4: Detailed specifications and primary function diagram.

4. Hardware Loriview and Protection

The module is designed with multiple protection mechanisms to ensure safe and reliable operation:

  • Power Supply Isolation: Provides stable isolated voltage, eliminating the need for an external power supply for the isolated terminal.
  • Magnetic Coupling Isolation: Ensures signal isolation, high reliability, strong anti-interference, and low power consumption.
  • Optocoupler Isolation: Prevents interference from high-voltage awọn iyika.
  • TVS Lightning & ESD Protection: Effectively suppresses surge voltage ati tionkojalo iwasoke voltage.
  • Fiusi Tunto: Provides over-current/over-voltage Idaabobo.
  • Dedicated Relay Driver Chip: With built-in flyback diode protection for stronger and more stable driving.
  • Reverse-Proof Circuit: Prevents accidental damage from incorrect power connection.
Hardware Analysis and Protection Circuits

Figure 5: Internal hardware components and protection circuits.

5. Digital Input Functionality

The module supports both passive (dry contact) and active (wet contact) digital inputs, with bi-directional optocoupler isolation and a built-in debouncing algorithm. This allows for flexible integration with various sensors and switches.

  • Passive Digital Input (Dry Contact): Connects to devices like button switches (self-reset) or ON/OFF switches (status hold).
  • Active Digital Input (Wet Contact): Connects to devices like NPN proximity sensors or IR curtain sensors.
Digital Input Connection Diagrams

Figure 6: Digital input types and connection diagrams.

6. Interfaces and Indicators

The module features multiple LED indicators to monitor its operating status and communication activity:

  • STA LED: MCU indicator, flashes when the MCU is operating normally.
  • TXD LED: TX indicator, lights up when sending data.
  • RXD LED: RX indicator, lights up when receiving data.
  • Relay Working Indicators: Individual LEDs for each relay channel indicate its current state (ON/OFF).
Awọn atọkun ati Awọn Atọka

Figure 7: Module interfaces and LED indicators.

7. Awọn ọna ṣiṣe

The module supports multiple relay control modes for various automation scenarios, with each channel supporting independent control settings:

  • Normal Mode (Command Direct Control): Relays are controlled directly by sending Modbus commands.
  • Flash ON / Flash OFF: Allows turning the relay ON for a specified duration and then automatically turning it OFF (Flash ON), or turning it OFF for a duration and then automatically turning it ON (Flash OFF). The duration is set by passing an argument to the command.
  • Iṣakoso Asopọ: The output status of a relay follows the digital input status, enabling direct control based on sensor readings or switch states.
  • Ipo Yipada: When a pulse is input, the output status of the relay will toggle once (ON to OFF, or OFF to ON).

8. RS485 ibaraẹnisọrọ

The module communicates via the RS485 interface using the Modbus RTU protocol. It supports configurable device addresses (1-255), allowing multiple modules to be cascaded on a single RS485 bus. For long communication distances or a large number of cascaded devices, RS485 repeaters may be necessary to maintain signal integrity and system efficiency.

RS485 Communication Diagram

Figure 8: RS485 communication setup with multiple cascaded devices.

9. Relay Connection

The onboard relays have a contact rating of ≤10A 250VAC/30VDC, allowing direct control of various devices. Ensure proper wiring according to the load type:

  • AC 220V Device Connection: Connect the AC load to the COM and NO (Normally Open) terminals of the relay.
  • DC 30V Device Connection: Connect the DC load to the COM and NO (Normally Open) terminals of the relay.

Always ensure the power supply to the module is within the 7~36V range.

10. Enclosure and Installation

The module is housed in a rail-mounted ABS plastic enclosure, designed for easy installation and secure mounting on standard DIN rails. This design simplifies integration into industrial control cabinets and systems, providing both convenience and safety.

11. Awọn ohun elo

The Waveshare Modbus RTU Relay series products are suitable for a wide range of applications requiring intelligent and automated control:

  • Industrial Control: Valve control, pump station control, unattended industrial control systems.
  • Ile Smart: Controlling appliances like air conditioners, access control, purifiers, water heaters, etc.
  • Smart Agriculture: Controlling door curtain motors, air blowers, and other agricultural equipment.
  • Breeding & Farming: Controlling ventilators, lighting, water supply, feeding systems, etc.

12. Outline Dimensions

The physical dimensions of the module are provided below for planning and integration purposes. All units are in millimeters (mm).

Outline Dimensions of the Module

Figure 9: Outline dimensions of the Modbus RTU Relay (D) module.

13. Laasigbotitusita

If you encounter issues with your Waveshare Industrial Modbus RTU 8-Channel Relay Module (D), please consider the following common troubleshooting steps:

  • Ko si Agbara/Atọka Pipa: Ṣayẹwo asopọ ipese agbara ati rii daju pe voltage is within the 7~36V range. Verify the power adapter is functioning correctly.
  • Ikuna ibaraẹnisọrọ: Ensure the RS485 A+, B-, and GND connections are correct and secure. Check the baudrate, parity, data bits, and stop bits settings on your Modbus master device match the module's default or configured settings. Verify the device address is unique and correctly set.
  • Relay Not Actuating: Confirm that the Modbus commands sent are correct for the desired relay action (ON/OFF, Flash, Linkage, Toggle). Check the load connected to the relay is within the specified contact rating (≤10A 250VAC/30VDC).
  • Digital Input Not Responding: Ensure the digital input connections are correct for either passive (dry contact) or active (wet contact) input. Verify the external switch or sensor is functioning properly.
  • Iṣiṣẹ Laarin: Check for loose connections or environmental interference. Ensure proper grounding.

For persistent issues, refer to the detailed product documentation available on the Waveshare website or contact Waveshare technical support.

14. Atilẹyin ọja ati Support

Waveshare products typically come with a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty information provided with your purchase or visit the official Waveshare website. Technical support is available through the Waveshare support channels, including online documentation, forums, and direct contact options. Please have your product model and purchase details ready when seeking support.

For the latest drivers, software, and detailed technical resources, please visit the Waveshare official webojula: www.waveshare.com

Awọn iwe aṣẹ ti o jọmọ - Modbus RTU Relay (D)

Ṣaajuview Ìtẹ̀síwájú Analog Waveshare Modbus RTU 8CH - Ìwé Ìtọ́sọ́nà Olùlò àti Ìlànà Ìmọ̀-ẹ̀rọ
Ìtọ́sọ́nà pípéye sí ẹ̀rọ Waveshare Modbus RTU Analog Input 8CH, tó bo àpèjúwe ẹ̀rọ, ìfiwéra ẹ̀yà, ìṣètò, ìdánwò sọ́fítíwè pẹ̀lú SSCOM àti Modbus Poll, àti àwọn ìlànà ìdàgbàsókè fún Raspberry Pi, STM32, àti Arduino.
Ṣaajuview Modbus RTU Relay: Ìwé Ìtọ́sọ́nà Olùlò àti Ìtọ́sọ́nà Ìmọ̀-ẹ̀rọ
Ìtọ́sọ́nà pípéye sí Modbus RTU Relay, tí ó bo àwọn ìlànà ààbò, ìsopọ̀ hardware, ìṣètò software pẹ̀lú SSCOM àti Modbus Poll, àti àwọn ìlànà àṣẹ tí a ṣàlàyé fún onírúurú iṣẹ́.ampawọn les fun isopọmọ Raspberry Pi, STM32, Arduino, ati PLC.
Ṣaajuview Module d'Entrée Analogique Modbus RTU 8 Canaux par Waveshare
Ce document technique présente le module d'entrée analogique 8 canaux Modbus RTU de Waveshare, conçu pour l'acquisition de données de tension et de courant dans les systèmes d'automatisation industrielle. Il détaille les spécifications techniques, les méthodes de connexion, les tests logiciels et le protocole de communication Modbus.
Ṣaajuview Ìwé Ìtọ́sọ́nà àti Ìtọ́sọ́nà Ìmọ̀-ẹ̀rọ Modbus RTU Relay 32CH
Ìwé ìtọ́ni tó péye àti ìtọ́sọ́nà ìmọ̀ ẹ̀rọ fún Modbus RTU Relay 32CH. Ó ní ààbò, ohun èlò, ìṣọ̀kan sọ́fítíwè (Raspberry Pi, STM32, Arduino, PLC), àti àwọn ìlànà àṣẹ Modbus RTU fún ìdáṣiṣẹ́ ilé iṣẹ́.
Ṣaajuview Modbus RTU E/S 8CH: Industrial 8-Channel Digital Input/Output Module
Comprehensive technical guide for the Waveshare Modbus RTU E/S 8CH module, detailing its specifications, wiring, primary functions, testing procedures, and Modbus communication protocol for industrial automation applications.
Ṣaajuview Modbus POE ETH Relay User Manual and Configuration Guide
Comprehensive guide for the Waveshare Modbus POE ETH Relay, covering hardware connection, safety instructions, parameter configuration using Vircom software and web interface, virtual serial port setup, and detailed Modbus RTU/TCP protocol commands and examples.