1. Ifihan
This manual provides detailed instructions for the safe and effective operation of the Mastfuyi FY02A Digital Multimeter. The FY02A is a compact, auto-ranging digital multimeter designed for measuring AC/DC voltage, AC/DC current, resistance, frequency, diode, and continuity. It also features Non-Contact Voltage (NCV) detection, a backlit LCD, data hold, and automatic power-off for energy conservation.
2. Alaye Aabo
ÌKÌLỌ̀: Láti yẹra fún ìkọlù iná mànàmáná tàbí ìpalára ara ẹni, ka gbogbo ìwífún nípa ààbò kí o tó lo ọjà yìí.
- Rí i dájú pé multimeter náà wà ní iṣẹ́ àti ìwọ̀n tó yẹ kí o tó ṣe àwọn ìwọ̀n.
- Ma ṣe wọn voltages exceeding the maximum rated input of 600V.
- Ṣọra pupọ nigbati o ba n ṣiṣẹ pẹlu awọn iyika laaye.
- Ṣe àyẹ̀wò àwọn ìdánwò ìdánwò fún ìbàjẹ́ kí o tó lò ó ní gbogbo ìgbà. Má ṣe lò ó tí ìdènà bá bàjẹ́.
- Replace the battery when the low battery indicator appears to ensure accurate readings.
- Má ṣe lo multimeter náà bí ó bá dàbí pé ó ti bàjẹ́ tàbí tí kò bá ṣiṣẹ́ dáadáa.
- The internal circuit includes two fuses (F250mA/250V and F10A/250V) and two PTC thermistors for overload protection.
- The rubber sheath provides protection against electric shock during use.
3. Package Awọn akoonu
Jẹrisi pe gbogbo awọn ohun kan wa ninu package:
- 1 x Mastfuyi FY02A Digital Multimeter
- Àwọn Ìdánwò 2 x (Pupa àti Dúdú)
- 1 x 9V Batiri
- 1 x Itọsọna olumulo

Image: The Mastfuyi FY02A Digital Multimeter, including test leads and a 9V battery.
4. Ọja Ipariview
Familiarize yourself with the components and controls of the multimeter.

Image: Detailed diagram of the Mastfuyi FY02A multimeter, highlighting the LCD display, function dial, input jacks, and control buttons.
- Ifihan LCD: Ṣe afihan awọn kika wiwọn, awọn ẹya, ati awọn afihan iṣẹ.
- Ṣiṣe ipe iṣẹ: A lo lati yan iṣẹ wiwọn ti a fẹ (Iwọn didun)tage, Current, Resistance, àti bẹ́ẹ̀ bẹ́ẹ̀ lọ).
- Bọtini Dimu: Didi kika lọwọlọwọ lori ifihan. Tẹ lẹẹkansi lati tu silẹ.
- Bọ́tìnì FUNK: Used to switch between AC/DC modes or other sub-functions within a dial setting.
- Bọtini Imọlẹhin: Activates the LCD backlight. Press and hold for 2 seconds to turn on; it automatically turns off after 15 seconds.
- Awọn Jacks ti nwọle:
- COM (Wọpọ) Jack: Fún àyẹ̀wò dúdú.
- VΩmA Jack: For the red test lead when measuring voltage, resistance, frequency, diode, continuity, and current up to 200mA.
- 10A Jack: For the red test lead when measuring current up to 10A.
5. Eto
5.1 Fifi sori batiri
- Rii daju pe multimeter ti wa ni pipa.
- Wa ideri iyẹwu batiri ni ẹhin ẹyọ naa.
- Tú àwọn skru tí ó wà ní ìpamọ́ náà kí o sì yọ ìbòrí náà kúrò.
- Insert the 9V battery, observing correct polarity (+ and -).
- Rọpo ideri batiri naa ki o si fi skru(s) so o mọ.
5.2 Nsopọ Awọn itọsọna Igbeyewo
- Fi dudu igbeyewo asiwaju sinu COM (Wọpọ) jack.
- Fi okun idanwo pupa sinu apoti titẹ sii ti o yẹ fun wiwọn rẹ:
- Fun Voltage, Resistance, Frequency, Diode, Continuity, and mA current: use the VΩmA jaki.
- For 10A current: use the 10A jaki.
- Before use, remove the protective caps from the test lead tips.

Image: Illustration demonstrating the removal of protective caps from the test lead tips before use.
6. Awọn ilana Iṣiṣẹ
The Mastfuyi FY02A features auto-ranging, simplifying operation by automatically selecting the correct measurement range.
6.1 Iwọn AC / DC Voltage
- Ṣeto ipe kiakia iṣẹ si V~ (Ìdìpọ̀ ACtage) tabi V- (DC Voltage) position. The multimeter will automatically detect AC or DC.
- Fi asiwaju igbeyewo pupa sinu VΩmA jack and the black test lead into the COM jaki.
- So àwọn ìwádìí ìdánwò pọ̀ mọ́ àyíká tàbí èròjà tí o fẹ́ wọ̀n.
- Ka voltage iye lori ifihan LCD.

Image: A user demonstrating how to measure the voltage of a 9V battery using the multimeter's test leads.
6.2 Measuring AC/DC Current
- Ṣeto ipe kiakia iṣẹ si A~ (AC Current) tàbí A- (Ipo DC Current).
- For currents up to 200mA, insert the red test lead into the VΩmA jack. For currents up to 10A, insert the red test lead into the 10A jack. The black test lead always goes into the COM jaki.
- IKILO: Connect the multimeter in series with the circuit. Do not connect in parallel across a voltage source when measuring current, as this can damage the meter and circuit.
- Ka awọn ti isiyi iye lori LCD àpapọ.
6.3 Idiwọn Resistance
- Ṣeto ipe kiakia iṣẹ si Ω Ipò (àtakò).
- Fi asiwaju igbeyewo pupa sinu VΩmA jack and the black test lead into the COM jaki.
- Rí i dájú pé agbára ìṣiṣẹ́ tàbí ohun èlò náà ti dínkù kí o tó wọn agbára ìdènà.
- So awọn iwadii idanwo kọja paati naa.
- Ka iye resistance lori ifihan LCD.

Image: A user measuring the resistance of a component on a circuit board using the multimeter.
6.4 Igbeyewo Ilọsiwaju
- Ṣeto ipe kiakia iṣẹ si Ω (Resistance) position and press the FUNC button until the continuity symbol (a speaker icon) appears on the display.
- Fi asiwaju igbeyewo pupa sinu VΩmA jack and the black test lead into the COM jaki.
- Rí i dájú pé agbára ìṣiṣẹ́ tàbí ohun èlò náà kò pọ̀.
- So awọn wadi igbeyewo kọja awọn Circuit ona tabi paati.
- If the resistance is less than approximately 100Ω, the buzzer will sound, indicating continuity.

Image: A user performing a continuity test, indicated by the multimeter's display and an audible alert.
6.5 Idanwo Diode
- Ṣeto ipe kiakia iṣẹ si Ω (Resistance) position and press the FUNC button until the diode symbol appears on the display.
- Fi asiwaju igbeyewo pupa sinu VΩmA jack and the black test lead into the COM jaki.
- Ensure the diode is de-energized.
- So ohun èlò pupa mọ́ anode, kí ohun èlò dúdú náà sì so mọ́ katódì ti diode náà. Ìfihàn náà yóò fi ohun èlò iwájú hàn.tage ju.
- Reverse the probes. The display should show "OL" (Overload) for a good diode, indicating high resistance in the reverse direction. If "OL" is displayed in both directions or a value is shown in both directions, the diode may be faulty.

Image: A user performing a diode test, with the multimeter displaying "OL" for an open circuit in one direction.
6.6 Non-olubasọrọ Voltage (NCV) erin
- Ṣeto ipe kiakia iṣẹ si NCV ipo.
- Bring the top part of the multimeter close to the conductor.
- Ti AC voltage greater than 90V (RMS) is detected, the instrument's backlight will flash, and an audible alarm will sound.

Image: The multimeter detecting non-contact voltage near an electrical outlet, indicated by visual and audible alarms.
6.7 Data idaduro
Tẹ awọn DIMU button to freeze the current reading on the display. This is useful for recording unstable measurements or when the display is difficult to view directly. Press the DIMU button again to release the reading and resume live measurement.
6.8 Imọlẹ ẹhin
Tẹ mọlẹ Imọlẹ ẹhin button for 2 seconds to turn on the LCD backlight, improving visibility in dimly lit areas. The backlight will automatically turn off after 15 seconds to conserve battery power.
6.9 Agbara Aifọwọyi Pa
The multimeter will automatically power off after approximately 15 minutes of inactivity to save battery life. To reactivate, turn the function dial to OFF and then back to the desired measurement function.
7. Itọju
7.1 Ninu
Pa ọran naa pẹlu ipolowoamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun tí ó ń yọ́ omi. Rí i dájú pé multimeter náà gbẹ pátápátá kí o tó lò ó.
7.2 Batiri Rirọpo
When the low battery indicator appears on the display, replace the 9V battery as described in Section 5.1. Using a low battery can lead to inaccurate readings.
7.3 Fiusi Rirọpo
If the current measurement function stops working, the fuse may need replacement. This should only be performed by qualified personnel. The internal fuses are F250mA/250V and F10A/250V.
8. Laasigbotitusita
- No Display / Power On Issue: Check battery installation and charge. Replace battery if necessary.
- "OL" Ti a fihan:
- In resistance mode: Indicates an open circuit or resistance beyond the meter's range.
- In diode mode (reverse bias): Normal for a good diode.
- In current mode: Indicates current exceeding the selected range. Switch to a higher range (e.g., 10A jack) or check for an open circuit.
- Awọn kika ti ko pe:
- Ṣayẹwo ipele batiri.
- Ensure test leads are fully inserted and not damaged.
- Verify the correct function and range are selected.
- Ko si Beep Tesiwaju: Ensure the continuity function is selected (speaker icon on display). Check if the circuit resistance is above 100Ω.
9. Awọn pato
| Paramita | Iye |
|---|---|
| Nọmba awoṣe | FY02A |
| Ifihan | 2000 Counts, Backlit LCD |
| Ibiti o wa | Aifọwọyi-Range |
| DC Voltage | 200mV - 600V |
| AC Voltage | 2V - 600V |
| DC Lọwọlọwọ | 200µA - 10A |
| AC Lọwọlọwọ | 200µA - 10A |
| Atako | 200Ω - 20MΩ |
| Igbohunsafẹfẹ | 200Hz - 200kHz |
| Idanwo Diode | Bẹẹni |
| Igbeyewo Ilọsiwaju | Yes (Buzzer < 100Ω) |
| Iwari NCV | Yes (>90V RMS) |
| Idaduro data | Bẹẹni |
| Agbara Aifọwọyi Paa | Bẹẹni (lẹhin iṣẹju 15) |
| Orisun agbara | 9V batiri |
| Awọn iwọn | 16.8 x 11.5 x 4.7 cm |
| Iwọn | 320 giramu |
| Awọn Ilana Abo | CE, RoHS |
10. Atilẹyin ọja ati Support
Mastfuyi provides a 48-month unconditional warranty and lifetime after-sales service for this product. For technical support or warranty claims, please contact Mastfuyi customer service. Contact information can typically be found on the product packaging or the official Mastfuyi webojula.
The manufacturer offers 24-hour consulting services for product-related questions.