ERICKHILL ROOK800P

ERICKHILL Infrared Thermometer Gun ROOK800P User Manual

Model: ROOK800P | Brand: ERICKHILL

1. Ifihan

The ERICKHILL Infrared Thermometer Gun ROOK800P is a versatile dual-mode temperature measurement device, combining a non-contact infrared sensor with a detachable stainless-steel probe. It is designed for accurate and rapid temperature readings across a wide range of applications, from cooking and BBQ to industrial and home use. This manual provides essential information for safe and effective operation.

2. Alaye Aabo

IKILO: This device uses a Class II laser. Do not aim the laser directly at eyes or reflective surfaces. Avoid direct exposure to the laser beam. This product is not a medical device and should not be used for measuring human body temperature.

3. Ọja Ipariview

The ERICKHILL ROOK800P features a robust design with an easy-to-read backlit LCD display. It includes both non-contact infrared measurement and a contact probe for internal temperatures.

ERICKHILL Infrared Thermometer Gun ROOK800P with probe and carrying case

Figure 1: ERICKHILL Infrared Thermometer Gun ROOK800P with its detachable probe and protective carrying case.

4. Eto

4.1 Fifi sori batiri

  1. Wa ibi ipamọ batiri naa lori ọwọ naa.
  2. Ṣii ideri iyẹwu naa.
  3. Fi awọn batiri AAA meji sii, ki o rii daju pe polarity ti o tọ (+/-).
  4. Pa ideri batiri naa ni aabo.

4.2 Attaching the Temperature Probe

The detachable meat probe connects to a port on the side of the thermometer gun. Simply insert the probe's jack into the designated port until it clicks into place.

Video: Official ERICKHILL STORE video demonstrating the product features, including probe attachment and usage.

5. Awọn ilana Iṣiṣẹ

5.1 Agbara Tan / Pa

To power on the device, pull the trigger. The device will automatically power off after 15 seconds of inactivity to conserve battery life.

5.2 Switching Measurement Modes (IR / Probe)

Tẹ awọn IR/PR button to toggle between Infrared (non-contact) and Probe (contact) measurement modes. The display will indicate the active mode.

5.3 Temperature Units (°C / °F)

Tẹ awọn ° C / ° F bọtini lati yipada laarin awọn iwọn otutu Celsius ati Fahrenheit.

5.4 Laser Aiming

In IR mode, the laser pointer can be activated or deactivated by pressing the laser button. The laser helps pinpoint the measurement area for non-contact readings.

5.5 Àtúnṣe Ìtújáde Ìtújáde

The emissivity setting (0.10-0.99) allows for precise temperature measurements across various materials. Refer to the manual's emissivity chart for common materials. Press the MODE button to access emissivity settings.

Infrared thermometer displaying adjustable emissivity setting from 0.10 to 0.99

Figure 2: The thermometer's display showing the adjustable emissivity setting, crucial for accurate readings on different surfaces.

5.6 Max/Min/Avg Modes

Tẹ awọn MODE button repeatedly to cycle through Max, Min, and Average temperature display modes during continuous measurement.

5.7 Using IR Mode (Non-Contact)

Point the infrared sensor at the target object and pull the trigger. The laser will indicate the measurement spot. The display will show the surface temperature. Maintain an optimal distance for accuracy (refer to the device's spot ratio diagram, typically around 360mm for a 30mm spot).

Person using the infrared thermometer to measure the surface temperature of a cooking steak on a griddle.

Figure 3: Measuring the surface temperature of food on a griddle using the non-contact infrared function.

5.8 Using Probe Mode (Contact)

Ensure the probe is securely attached and the device is in Probe mode. Insert the stainless-steel probe into the object (e.g., meat, liquid) to measure its internal temperature. Allow a few seconds for the reading to stabilize.

Person using the detachable probe of the ERICKHILL thermometer to measure the internal temperature of a steak.

Figure 4: Using the detachable probe to accurately measure the internal temperature of food.

6. Awọn ohun elo

The ERICKHILL ROOK800P is suitable for a wide array of temperature measurement tasks:

Collage showing various applications of the ERICKHILL thermometer, including cooking, automotive checks, and general temperature measurement.

Figure 5: Versatile applications of the thermometer, from kitchen to automotive and industrial settings.

7. Awọn pato

Ẹya ara ẹrọIye
Ibiti Igba otutu IR-50°C si 800°C (-58°F si 1472°F)
Iwadi Iwọn otutu-50°C si 300°C (-58°F si 572°F)
Yiye±2°C
Akoko Idahun0.5 aaya
Ijinna-to-Aami Ratio12:1
EmissivityAdjustable (0.10-0.99)
Orisun agbara2 x Awọn batiri AAA (pẹlu)
Aifọwọyi Agbara-PaaAwọn aaya 15 (isunmọ)
Ifihan IruDíjítàlì, LCD ẹ̀yìn títàn
Ohun eloABS Body, Stainless-Steel Probe

8. Itọju

9. Laasigbotitusita

IsoroOwun to le Fa / Solusan
Ko si ifihan / Ẹrọ kii yoo tanCheck battery installation and replace if necessary. Ensure the trigger is fully pressed.
Àwọn kíkà IR tí kò péyeVerify emissivity setting for the target material. Ensure proper distance-to-spot ratio. Avoid measuring through glass or highly reflective surfaces. Allow device to acclimate to ambient temperature if moved from extreme conditions.
Inaccurate Probe readingsEnsure the probe is fully inserted into the object and has sufficient time to stabilize. Check for proper connection of the probe to the device.
Lesa ko hanEnsure the laser aiming function is activated (check display icon).

10. Atilẹyin ọja ati Support

ERICKHILL products typically come with a manufacturer's warranty. Please refer to the product packaging or the official ERICKHILL webojula fun pato atilẹyin ọja awọn alaye.

For technical support or customer service, please contact ERICKHILL support at: support@erick-hill.com

Awọn iwe aṣẹ ti o jọmọ - ROOK800P

Ṣaajuview ERICKHILL ROOK 400/600 SP IR Itanwo Itọsọna olumulo
Itọsọna olumulo fun ERICKHILL ROOK 400 SP ati ROOK 600 SP infurarẹẹdi thermometers. Pese awọn itọnisọna lori iṣẹ, awọn ẹya, ailewu, ati awọn alaye imọ-ẹrọ.
Ṣaajuview ERICKHILL ER02 EMF Mita Itọsọna olumulo
Ṣawari awọn agbara ti ERICKHILL ER02 EMF Mita pẹlu itọnisọna olumulo okeerẹ yii. Kọ ẹkọ nipa iṣẹ ṣiṣe 3-in-1 rẹ fun wiwọn ina, oofa, ati awọn aaye igbohunsafẹfẹ redio, pẹlu iṣẹ ṣiṣe, awọn pato, ati awọn itọnisọna ailewu.
Ṣaajuview Erickhill RT-100S EMF Mita olumulo Afowoyi
Itọsọna olumulo fun Erickhill RT-100S EMF Mita, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, awọn alaye imọ-ẹrọ, ati awọn ohun elo fun wiwọn ina, oofa, ati awọn aaye RF.