The Elitech VGW-Mini is a compact and versatile wireless digital vacuum gauge designed for HVAC and refrigeration systems. It provides accurate vacuum measurements, features app connectivity for monitoring and data management, and includes an adaptor for convenient use. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your device.

Elitech VGW-Mini Wireless Digital Vacuum Gauge with included adapter

Image 1: Elitech VGW-Mini Wireless Digital Vacuum Gauge with included adapter.

2. Eto

2.1 Unboxing ati Ibẹrẹ ayewo

Ni ifarabalẹ yọ gbogbo awọn paati kuro ninu apoti. Jẹrisi pe awọn nkan wọnyi wa:

2.2 Batiri sori ati gbigba agbara

The VGW-Mini requires 1 Lithium Ion battery (included). Ensure the battery is properly installed. For charging, connect the device using a standard USB cable. The device is rechargeable.

Elitech VGW-Mini showing USB charging port and dimensions

Image 2: Elitech VGW-Mini connected via USB for charging, illustrating its compact dimensions.

2.3 Connecting the Adaptor

Attach the provided 1/4" SAE adaptor to the vacuum gauge. Ensure it is securely fastened to prevent leaks during operation.

2.4 Elitech Tools App Installation

Download the Elitech Tools App from your device's app store (iOS and Android compatible). This integrated app allows for remote monitoring, data recording, and management of Elitech tools.

Elitech Tools App interface showing monitoring and data export options

Image 3: The Elitech Tools App interface demonstrating monitoring capabilities and data export functions.

3. Awọn ilana Iṣiṣẹ

3.1 Agbara Tan / Pa ati Ifihan

Press the power button to turn the device on or off. The large, full-view LCD screen provides a continual digital readout of the evacuation process. The device supports multiple units of measurement.

Elitech VGW-Mini highlighting features like app support, OTA upgrade, offline record, and large display

Image 4: Elitech VGW-Mini showcasing its key features including app support, OTA upgrades, offline recording, and a large display.

3.2 Wiwọn igbale

Connect the VGW-Mini to the HVAC or refrigeration system using the 1/4" SAE adaptor. The gauge measures vacuum from 19,000 Microns (atmosphere) down to 0 Micron with an accuracy of ±10% or ±10 Micron.

3.3 H2O Status Judgment

The vacuum meter automatically assesses the physical state of H2O by comparing the ambient temperature with the water saturation temperature corresponding to the system's vacuum level.

Elitech VGW-Mini display showing H2O status judgment with temperature readings

Image 5: The VGW-Mini's display indicating H2O status judgment based on temperature and vacuum readings.

3.4 App Connectivity and Data Management

Pair the VGW-Mini with the Elitech Tools App via Bluetooth. The app allows you to:

Elitech VGW-Mini connected to the app, showing a vacuum graph and data

Image 6: The Elitech VGW-Mini connected to the mobile app, displaying a vacuum graph and detailed data.

4. Itọju

4.1 Sensọ Cleaning

Regular cleaning of the sensor is crucial for maintaining accurate readings. Oil or contaminants can impact accuracy. Refer to the manufacturer's guidelines for specific cleaning procedures. Generally, this involves carefully removing any debris and cleaning with an appropriate solvent like denatured alcohol, ensuring the sensor is completely dry before reassembly.

4.2 Oil Proof Film

The product includes an oil proof film inside its head. If directly connecting to a vacuum pump, this film may cause a delayed numerical display. It is suggested to remove the oil film when connecting to the vacuum pump and reinstall it when connecting to the system to prevent oil contamination.

4.3 batiri Itọju

To prolong battery life, charge the device regularly and avoid fully discharging it. Store the device in a cool, dry place when not in use.

5. Laasigbotitusita

5.1 Delayed Numerical Display

If you experience a delayed numerical display when connected directly to a vacuum pump, consider temporarily removing the internal oil proof film as described in Section 4.2. Reinstall the film when connecting to the system.

5.2 Awọn kika ti ko pe

Inaccurate readings can often be attributed to a contaminated sensor. Perform a thorough sensor cleaning as outlined in Section 4.1. Ensure all connections are tight and leak-free.

5.3 App Asopọmọra Oran

Ensure Bluetooth is enabled on your mobile device and the VGW-Mini is within range. Restart both the device and the app if connection problems persist. Verify that the Elitech Tools App is updated to the latest version.

6. Awọn pato

Elitech VGW-Mini showing weight, measuring range, operating temperature, interface, accuracy, and resolution

Image 7: Detailed technical specifications and physical attributes of the Elitech VGW-Mini.

Ẹya ara ẹrọSipesifikesonu
OlupeseElitech
Nọmba apakanVGW-mini+ad
Iwọn Nkan209 g (0.44 lb)
Ọja Mefa12.45 x 3.56 x 2.79 cm (4.9 x 1.4 x 1.1 inches)
Awọn batiri1 batiri litiumu ion (pẹlu)
Ohun eloṢiṣu
Yiye wiwọn±10% or ±10 Micron
Iwọn Iwọn0-19000 Micron
Ni wiwo1/4" SAE
Ipinnu0-400 Micron: 1 Micron
400-3000 Micron: 10 Micron
3000-10000 Micron: 100 Micron
10000-19000 Micron: 250 Micron

7. Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the official Elitech website or contact Elitech customer service directly. The Elitech Tools App may also provide access to support resources and firmware updates (OTA Upgrade).

Awọn iwe aṣẹ ti o jọmọ - VGW-mini+ad

Ṣaajuview VGW 760 Wireless Digital Vacuum Gauge User Manual
Comprehensive user manual for the Elitech VGW 760 Wireless Digital Vacuum Gauge, covering overview, features, specifications, operation instructions, cleaning, app usage, warnings, and package contents for HVAC and refrigeration applications.
Ṣaajuview Elitech MS-100 Digital Manifold Gauge User Afowoyi
Itọsọna olumulo fun Elitech MS-100 Digital Manifold Gauge, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, awọn pato, ati itọju.
Ṣaajuview Elitech MS-100 Digital Manifold Gauge: Àwọn Ẹ̀yà Ara Rẹ̀, Iṣẹ́ Rẹ̀, àti Àwọn Ìlànà Tí Ó Yẹ Kí Ó Ṣe
Ìtọ́sọ́nà pípéye sí Elitech MS-100 Digital Manifold Gauge, tí ó ní àwọn ẹ̀yà ara rẹ̀, iṣẹ́ kíákíá, àwọn ìlànà ìmọ̀-ẹ̀rọ, àwọn ìṣọ́ra, àti àwọn àlàyé ọjà fún àwọn ètò HVAC àti fìríìjì.
Ṣaajuview Elitech MS Series Digital Manifold Gauge User Afowoyi
Iwe afọwọkọ olumulo fun Elitech MS Series oni ọpọlọpọ iwọn, ti o bo apejuwe ọja, gbogbogbo ti pariview, Awọn iṣẹ bọtini, awọn pato, itọsọna ibẹrẹ ni kiakia, awọn igbesẹ iṣẹ, awọn ohun elo ti oye, ati itọju.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Elitech MS-100 PLUS Smart Digital Manifold Gauge
Ìwé ìtọ́nisọ́nà oníṣe tó péye fún Elitech MS-100 PLUS Smart Digital Manifold Gauge, tó bo ìfihàn ọjà, àwọn ìtọ́ni ààbò, lóríview, awọn iṣẹ bọtini, awọn paramita imọ-ẹrọ, ati awọn itọsọna iṣiṣẹ iyara fun awọn eto firiji ati HVAC.
Ṣaajuview Ìwé Ìtọ́sọ́nà àti Àwọn Ìlànà Ìtọ́sọ́nà Oní-ẹ̀rọ Oní-ẹ̀rọ Elitech MS-800 Series
Ìwé ìtọ́ni tó péye fún ẹ̀rọ ìṣiṣẹ́ oní-nọ́ńbà oní-nọ́ńbà Elitech MS-800 Series, tó ní í ṣe pẹ̀lú ìfihàn ọjà, àwọn ìlànà ààbò, ààbò àyíká, àwọn ìlànà pàtó, àti àwọn ìtọ́sọ́nà ìṣiṣẹ́ kíákíá fún ìwọ̀n ìfúnpá àti iwọ̀n otútù, ìdánwò ìfúnpá, àti gbígbà agbára ìfọ́jú fún àwọn ẹ̀rọ HVAC àti fìríìjì.