Anern Anern 6200W Hybrid Solar Inverter

Anern 6200W Hybrid Solar Inverter User Manual

Comprehensive guide for installation, operation, and maintenance of your Anern 6200W Hybrid Solar Inverter.

1. Ifihan

Thank you for choosing the Anern 6200W Hybrid Solar Inverter. This advanced all-in-one inverter combines the functions of an inverter, solar charger, and battery charger to provide uninterrupted power support for your off-grid solar system. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your inverter. Please read it thoroughly before installation and use.

2. Alaye Aabo

Máa tẹ̀lé àwọn ìlànà ààbò wọ̀nyí láti dín ewu ìkọlù iná mànàmáná, iná, tàbí ìpalára kù:

3. Ọja Ipariview

The Anern 6200W Hybrid Solar Inverter is a pure sine wave inverter designed for robust performance in off-grid solar applications. It features a built-in 120A MPPT solar charge controller and supports operation without a battery.

Awọn ẹya pataki:

Awọn Irinṣẹ Ọja:

Anern 6200W Hybrid Solar Inverter front view

olusin 3.1: Iwaju view of the Anern 6200W Hybrid Solar Inverter.

Anern 6200W Hybrid Solar Inverter with labeled ports

Nọmba 3.2: Alaye view of the inverter showing LCD display, status indicators, function buttons, AC input/output, battery input, PV input, and communication ports.

Anern 6200W Hybrid Solar Inverter key specifications

Figure 3.3: Visual representation of key technical specifications including 6.2KW/48V, 48VDC nominal input, 120A max charging current, and 500VDC PV array open circuit voltage.

Awọn fidio ọja:

Fidio 3.1: Pariview of the Hybrid Solar Inverter with 120A MPPT Charge Controller, highlighting its features and benefits.

Video 3.2: Demonstrates the 6200W Hybrid Solar Inverter's capabilities, including its 48V DC to 220VAC conversion.

4. Eto ati fifi sori

Proper installation is crucial for the safe and efficient operation of your inverter. Follow these guidelines carefully.

4.1 Atokọ fifi sori ẹrọ tẹlẹ:

4.2 Aworan onirin:

The following diagram illustrates a typical wiring setup for the hybrid solar inverter, connecting to solar panels, batteries, AC input (utility/generator), and AC output loads.

Solar Inverter Wiring Diagram

Figure 4.1: Comprehensive wiring diagram showing connections for PV input (max 6500W, 500Vdc), 48V battery bank, 230VAC utility input, and 220-230VAC output. Recommended cable sizes and breaker ratings are indicated.

4.3 Dual AC Output Configuration:

The inverter features a dual AC output system to manage different load priorities. The primary output handles higher rated power appliances, while the secondary output is for less critical loads. In scenarios of low mains current or low battery voltage, the primary circuit may switch off, maintaining power only to the secondary output to conserve energy.

Dual AC Output Explanation

Figure 4.2: Illustration of the dual AC output functionality, showing primary output (6200W) for high-power devices and secondary output (2066W) for lower-power devices.

4.4 Battery Compatibility:

The Anern inverter is compatible with several types of 48V batteries, including Gel, FLD, Li-ion (Lithium), and AGM. Ensure your battery type is correctly configured in the inverter settings for optimal charging and discharge performance.

Battery Compatibility Types

Figure 4.3: Visual guide to compatible battery types: Gel, FLD, Li-ion, and AGM. The inverter supports a maximum battery charging current of 120A.

5. Awọn ọna ṣiṣe

The inverter offers flexible operating modes to suit various power management needs.

5.1 Awọn ọna gbigba agbara:

Select from four charging modes:

  1. Iyanju Oorun: Solar power is prioritized for charging batteries and powering loads.
  2. Àkọ́kọ́ Ohun Èlò: Utility power is prioritized for charging and loads, with solar as backup.
  3. Oorun ati Ohun elo: Both solar and utility power are used for charging and loads.
  4. Battery and Solar: Utilizes battery power first, then solar.

Àwọn Ìgbéjáde Mẹ́ta:

Choose from three output modes:

  1. Iyanju Oorun: Loads are powered by solar first, then battery, then utility.
  2. Àkọ́kọ́ Ohun Èlò: Loads are powered by utility first, then battery, then solar.
  3. SBU Mode (Solar-Battery-Utility): Loads are powered by solar, then battery, then utility.

5.3 RGB Working Mode Indicator:

The inverter features an RGB light indicator that changes color based on its operating status:

RGB Working Mode Display

Figure 5.1: RGB indicator showing different operating modes: White for Stationary, Violet for PV mode, Red for Battery mode, and Blue for Utility mode.

5.4 Wi-Fi Monitoring:

The system supports Wi-Fi monitoring, allowing you to control and monitor the inverter's operation via a mobile application (iOS/Android). This feature provides real-time data and remote management capabilities.

6. Itọju

Itọju deede ṣe idaniloju igbesi aye gigun ati iṣẹ ti o dara julọ ti oluyipada rẹ.

7. Laasigbotitusita

Abala yii n pese awọn ojutu fun awọn ọran ti o wọpọ ti o le ba pade.

IsoroOwun to le FaOjutu
Oluyipada ko titanNo DC input from battery/PV; On/Off switch off; Blown fuse.Check battery and PV connections; Ensure switch is ON; Inspect and replace fuses if necessary.
Ko si AC jadeOverload; Over-temperature; Short circuit; Low battery voltage.Reduce load; Ensure proper ventilation; Check for short circuits; Charge batteries. The inverter has automatic restart when AC power is restored.
Ina gbigba agbara kekereInsufficient solar input; MPPT controller issue; Battery fault.Check solar panel connections and sunlight; Verify MPPT settings; Inspect battery health.
Inverter display shows error codeInternal fault or specific protection triggered.Refer to the inverter's LCD display for specific error codes and consult the manufacturer's support for detailed resolution.

The Anern Solar Inverter includes built-in protections against Overload, Over-temperature, and Short circuit. If an issue persists, contact customer support.

8. Imọ ni pato

Detailed technical specifications for the Anern 6200W Hybrid Solar Inverter:

Ẹya ara ẹrọSipesifikesonu
AwoṣeAnern 6200W Hybrid Solar Inverter
Ti won won Agbara6200W
DC Input Voltage48V
AC wu Voltage220-230VAC
Fọọmu igbiWave Sine Sure
MPPT Solar Charge Controller Current120A
O pọju. PV orun Open Circuit Voltage450Vdc
Max. PV Agbara Agbara6500W
Max PV No-Load Voltage500Vdc
Ti won won Jade Lọwọlọwọ44.3Amp
Ọja Mefa16.92 x 8.26 x 21.65 inches
Iwọn Nkan24.2 iwon
Battery Capacity (Controller)120 Amp Hours (Max. charging current)

9. Atilẹyin ọja ati Support

Anern provides a one-year maintenance service for this inverter. If you encounter any malfunctions, please provide pictures or videos of the issue to the professional after-sales team. They will diagnose the cause and assist with component replacement if necessary.

For further assistance or technical support, please refer to the contact information provided with your purchase or visit the official Anern webojula.

Awọn iwe aṣẹ ti o jọmọ - Anern 6200W Hybrid Solar Inverter

Ṣaajuview Anern Pure Sine Wave Hybrid Inverter Afọwọṣe: Fifi sori, Aabo, ati Itọsọna Iṣiṣẹ
Itọsọna olumulo yii n pese aabo okeerẹ, fifi sori ẹrọ, ati awọn itọnisọna iṣẹ ṣiṣe fun Anern Pure Sine Wave Hybrid Inverter. O ni wiwa alaye pataki lori awọn irinṣẹ, onirin, ati iṣeto eto fun awọn solusan agbara igbẹkẹle.
Ṣaajuview ANERN FGI-S12000 Hybrid Solar Inverter User Manual
User manual for the ANERN FGI-S12000 Hybrid Solar Inverter. This guide details the installation, operation, safety, and specifications of the 12KW solar energy storage system, featuring MPPT charge control and UPS functionality.
Ṣaajuview ANERN FGI-P6500 MPPT Solar Inverter User Manual
Explore the ANERN FGI-P6500 MPPT Solar Inverter with this comprehensive user manual. Learn about installation, operation, safety, and troubleshooting for your solar energy storage system.
Ṣaajuview 2.0KVA/3.2KVA Inverter MPPT SCC AC Ṣaja olumulo Afowoyi
Iwe afọwọkọ olumulo pipe fun oluyipada 2.0KVA/3.2KVA pẹlu MPPT SCC ati Ṣaja AC. Ni wiwa fifi sori ẹrọ, iṣẹ ṣiṣe, awọn ẹya, awọn pato, ati laasigbotitusita. Pẹlu awọn ilana aabo, faaji eto, ati awọn eto alaye fun iṣẹ ṣiṣe to dara julọ.
Ṣaajuview Anern Hybrid Solar Inverter/Charger User Manual (3.5KVA/5.5KVA)
User manual for the Anern Hybrid Solar Inverter/Charger models 3.5KVA and 5.5KVA. Provides detailed instructions on installation, operation, specifications, and troubleshooting for this solar power system component.
Ṣaajuview Anern MPPT Solar Inverter Product Manual: AN-FGI-AS12000 & AN-FGI-AS12000P
Comprehensive product manual for Anern AN-FGI-AS12000 and AN-FGI-AS12000P MPPT solar inverters. Covers installation, operation, safety, troubleshooting, and technical specifications for efficient solar energy management.