Friedrich CCV15A10A

Friedrich Chill Premier Inverter User Manual

Model: CCV15A10A

15,000 BTU 115v Cooling Only Window & Wall Unit

1. Alaye Aabo pataki

Please read all instructions carefully before installing or operating your Friedrich Chill Premier Inverter air conditioner. Retain this manual for future reference.

WARNING: Risk of Fire or Explosion

Aabo Itanna: Rí i dájú pé ẹ̀rọ náà so mọ́ ihò ìtẹ̀jáde tí ó ní ilẹ̀ dáadáa pẹ̀lú ìpele tí ó tọ́tage (115V). Do not use extension cords. Disconnect power before servicing.

Aabo fifi sori ẹrọ: Follow all local and national electrical codes. Ensure the unit is securely installed to prevent falling. Do not block air vents.

Awọn iṣọra gbogbogbo: Keep children and pets away from the unit during operation. Do not insert objects into the air vents. Do not operate with a damaged power cord or plug.

2. Ọja Ipariview

The Friedrich Chill Premier Inverter is a high-efficiency window and wall air conditioning unit designed for precise temperature control and quiet operation. It features advanced inverter technology and is Energy Star certified, offering significant energy savings.

Iwaju view of the Friedrich Chill Premier Inverter air conditioner with digital display and control buttons.

olusin 2.1: Iwaju view of the Friedrich Chill Premier Inverter unit.

This image displays the front of the Friedrich Chill Premier Inverter air conditioner, highlighting its sleek design, digital temperature display, and intuitive control buttons located above the main air intake grille.

Awọn ẹya pataki:

Couple smiling with Friedrich Chill Premier Inverter unit in background, text 'Precise performance meets quiet comfort'.

Figure 2.2: Precise performance and quiet comfort.

This image illustrates the quiet operation and precise performance of the Chill Premier Inverter, showing a couple comfortably enjoying their living space with the unit in the background.

3. Eto ati fifi sori

The Friedrich Chill Premier Inverter unit is designed for simplified installation in both window and through-the-wall applications. Always ensure proper support and sealing to maximize efficiency and prevent water intrusion.

3.1 Window fifi sori

The unit features a three-step window installation process with a one-piece frame, simplifying setup. The unique SimpleSill™ Design allows you to open and close your window even after the unit is installed, providing flexibility for fresh air when cooling is not needed.

  1. Prepare the window opening according to the dimensions provided in the specifications.
  2. Assemble the one-piece frame and securely mount it in the window.
  3. Carefully slide the air conditioner unit into the installed frame.
  4. Secure the unit and seal any gaps to prevent air leakage.
  5. Ensure the unit is slightly tilted outwards to allow for proper condensate drainage.
Friedrich Chill Premier Inverter unit installed in a window in a living room setting.

Figure 3.1: Easy three-step window installation.

This image demonstrates the Friedrich Chill Premier Inverter unit seamlessly installed in a window, showcasing its adaptable design within a typical living room environment.

3.2 odi fifi sori

For through-the-wall installation, a wall sleeve (sold separately) is typically required. Consult the detailed installation guide provided with the wall sleeve for specific instructions and structural requirements.

  1. Ensure the wall opening is properly sized and reinforced to support the unit's weight.
  2. Install the wall sleeve according to its instructions, ensuring it is level and sealed.
  3. Slide the air conditioner unit into the wall sleeve.
  4. Secure the unit and apply weather stripping or sealant around the edges to prevent drafts and moisture.
Woman opening a window with the Friedrich Chill Premier Inverter unit installed, demonstrating SimpleSill Design.

Figure 3.2: SimpleSill™ Design for window flexibility.

This image highlights the SimpleSill™ Design feature, showing a user easily opening a window even with the air conditioner installed, allowing for natural ventilation.

4. Awọn ilana Iṣiṣẹ

Your Friedrich Chill Premier Inverter unit offers various modes and settings for optimal comfort and energy efficiency.

4.1 Pánẹ́lì Ìṣàkóso àti Ọ̀nà Ààbò

The unit can be controlled via the intuitive control panel on the front of the unit or the included remote control. The digital display shows the current temperature and selected settings.

4.2 Awọn ọna ṣiṣe

4.3 Smart Wi-Fi Control

Control your air conditioner from anywhere using the FriedrichGo™ app on your smartphone or tablet. The unit is also compatible with Amazon Alexa and Google Assistant for voice control.

  1. Download the FriedrichGo™ app from your device's app store.
  2. Tẹle awọn ilana inu-app lati so ẹrọ amúlétutù rẹ pọ̀ mọ́ nẹtiwọọki Wi-Fi ile rẹ.
  3. Once connected, you can adjust settings, set schedules, and monitor the unit remotely.
Woman using a smartphone to control the Friedrich Chill Premier Inverter unit, with Amazon Alexa and Google Assistant logos.

Figure 4.1: Smart Wi-Fi Control via FriedrichGo™ app.

This image demonstrates the convenience of controlling the Friedrich Chill Premier Inverter unit remotely using the FriedrichGo™ app on a smartphone, highlighting its compatibility with smart home assistants.

5. Itọju

Itọju deede ṣe idaniloju iṣẹ ṣiṣe ti o dara julọ ati igbesi aye gigun ti afẹfẹ afẹfẹ rẹ.

5.1 Ninu Ajọ Afẹfẹ

The unit is equipped with a washable air filter. A dirty filter can reduce cooling efficiency and airflow. Clean the filter every two weeks or more frequently if the unit is used heavily or in dusty environments.

  1. Pa afẹ́fẹ́ afẹ́fẹ́ náà kí o sì yọ ọ́ kúrò nínú ihò agbára.
  2. Locate and remove the air filter from the front grille.
  3. Wẹ àlẹmọ pẹlu gbona, omi ọṣẹ. Fi omi ṣan daradara.
  4. Allow the filter to air dry completely before reinstalling. Do not use heat to dry.
  5. Tun fi àlẹmọ gbẹ sinu ẹyọ.

5.2 Ninu Unit Ode

Mu ese ita kuro pẹlu asọ, damp Aṣọ. Má ṣe lo àwọn kẹ́míkà líle, àwọn ohun ìpara, tàbí àwọn ohun olómi, nítorí pé wọ́n lè ba ojú ilẹ̀ jẹ́.

5.3 Coil Maintenance

The unit features corrosion-resistant coils, which help prolong their lifespan. Periodically inspect the outdoor coils for dirt and debris. If heavily soiled, professional cleaning may be required to maintain efficiency.

Ẹyìn view of the Friedrich Chill Premier Inverter unit showing the condenser coils.

olusin 5.1: Ẹyìn view showing condenser coils.

Aworan yi pese a view of the rear of the air conditioner, revealing the condenser coils which are crucial for heat exchange and cooling performance.

6. Laasigbotitusita

Before contacting customer service, try the following troubleshooting steps for common issues.

IsoroOwun to le FaOjutu
Ẹka ko ni tan-an.No power, tripped circuit breaker, unit unplugged.Ensure unit is plugged in. Check circuit breaker and reset if tripped. Verify power outlet is functional.
Ẹka n ṣe ariwo nla.Loose parts, fan obstruction, unit not level, internal component issue.Check for loose screws or panels. Ensure no objects are obstructing the fan. Verify the unit is level. If noise persists, contact customer support.
Itutu agbaiye ti ko to.Dirty air filter, blocked air vents, room too large, temperature setting too high.Clean the air filter. Ensure air intake and exhaust vents are clear. Verify room size is within unit capacity. Lower the temperature setting.
Omi jijo.Unit not tilted correctly, clogged drain pan/hose.Ensure the unit is slightly tilted outwards for proper drainage. Check and clear any blockages in the drain pan or hose.

If the problem persists after attempting these solutions, please contact Friedrich customer support.

7. Awọn pato

IwaIye
Orukọ BrandFriedrich
Alaye AwoṣeCCV15A10A
Agbara Itutu15,000 Awọn ẹya Gbona Ilu Gẹẹsi (BTU)
Voltage115 Volts
Wattage1600 watt
Iwọn Nkan100 iwon
Awọn iwọn Ọja (D x W x H)26 x 26 x 17 inches
Ariwo Ipele42 dB
Agbara423 Onigun Ẹsẹ
Iru fifi sori ẹrọWindow or Wall-mounted
Iru RefrigerantR-32
Ipin Iṣiṣẹ Agbara Igba Igba (SEER)14.4
Ifọwọsi Agbara StarBẹẹni

8. Atilẹyin ọja ati Onibara Support

This Friedrich Chill Premier Inverter unit is covered by a manufacturer's warranty. Please refer to the warranty card included with your product for specific terms, conditions, and duration. Keep your proof of purchase for warranty claims.

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact Friedrich customer support. Contact information can typically be found on the manufacturer's webaaye tabi lori apoti ọja.

Awọn orisun Ayelujara: Visit the official Friedrich webojú òpó wẹ́ẹ̀bù fún àwọn ìbéèrè tó ń wá síni lọ́kàn, àwọn ìwé àtúnṣe, àti àwọn ohun èlò ìrànlọ́wọ́.

Awọn iwe aṣẹ ti o jọmọ - CCV15A10A

Ṣaajuview Friedrich GO WiFi Eto Itọsọna fun Chill Premier & Uni-Fit Air Conditioners
Itọsọna okeerẹ si iṣeto Friedrich GO WiFi-agbara afẹfẹ afẹfẹ afẹfẹ rẹ. Kọ ẹkọ bii o ṣe le ṣe igbasilẹ ohun elo naa, ṣẹda akọọlẹ kan, sopọ si nẹtiwọọki rẹ nipa lilo awọn ipo CF tabi AP, ati ṣakoso AC rẹ latọna jijin. Pẹlu awọn imọran laasigbotitusita.
Ṣaajuview Friedrich Air Conditioner Wi-Fi isẹ Manuali
Iwe afọwọkọ yii n pese awọn itọnisọna okeerẹ fun sisẹ awọn air conditioners Friedrich pẹlu iṣẹ Wi-Fi, pẹlu iṣeto, laasigbotitusita, ati iṣakoso app fun awọn awoṣe bi Friedrich Connect, Friedrich Go, Kuhl, Kuhl Q, Wallmaster, FA Pro, FA Premier, ati Chill Premier/Unifit.
Ṣaajuview Awọn Afẹ́fẹ́ Afẹ́fẹ́ Yara Friedrich Chill Inverter Series: Fifi sori ẹrọ ati Iṣiṣẹ Iwe afọwọkọ
Ìwé ìtọ́ni yìí pèsè ìtọ́sọ́nà pàtàkì fún fífi sori ẹrọ àti ìṣiṣẹ́ fún àwọn afẹ́fẹ́ afẹ́fẹ́ Friedrich Chill Inverter® Series Room, pẹ̀lú àwọn ìtọ́ni ààbò, ìṣètò, lílò, àti ìṣòro fún àwọn àwòṣe CCV15, CCV18, àti CCV24.
Ṣaajuview Friedrich Itanna Window Air kondisona Awọn ilana ti nṣiṣẹ
Awọn ilana iṣiṣẹ pipe fun Friedrich Itanna Window Air Conditioners, aabo ibora, fifi sori ẹrọ, iṣẹ ṣiṣe, itọju, ati laasigbotitusita fun awọn awoṣe CCW15B10A, CCW18B30A, CCW24B30A, CEW18B33A, ati CEW24B33A.
Ṣaajuview Friedrich Chill Premier Series Room Air Conditioners Installation and Operation Manual
Comprehensive installation and operation manual for Friedrich Chill Premier Series Room Air Conditioners, covering safety, installation, operation, troubleshooting, and warranty information for models CCW15B10B, CCW18B30B, CCW24B33B, CEW18B33B, and CEW24B33B.
Ṣaajuview Friedrich Chill Inverter Series Room Air Conditioners Installation and Operation Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of Friedrich Chill Inverter Series Room Air Conditioners, including models CCV15, CCV18, and CCV24. It covers safety precautions, setup, troubleshooting, and other features to ensure optimal performance and longevity of the unit.