Ọrọ Iṣaaju
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Total Automatic Self-priming Jet Pump, model TWP415006. Please read this manual thoroughly before operating the pump to ensure proper use and to prevent damage or injury.
Awọn Itọsọna Aabo
Nigbagbogbo ṣe akiyesi awọn iṣọra ailewu atẹle lati dinku eewu ina, mọnamọna, tabi ipalara:
- Aabo Itanna: Rii daju pe ipese agbara ibaamu voltage (220-240V~50Hz). Always connect the pump to a properly grounded outlet. Do not operate the pump with a damaged cord or plug.
- Aabo omi: Do not pump flammable or corrosive liquids. Ensure the pump is not submerged unless specifically designed for submersible use. Protect the pump from freezing temperatures.
- Fifi sori: Install the pump in a dry, well-ventilated area, protected from direct sunlight and rain. Ensure stable mounting to prevent vibration.
- Itọju: Disconnect power before performing any maintenance or repairs. Only qualified personnel should perform repairs.
- Awọn ọmọde ati awọn ohun ọsin: Pa awọn ọmọde ati awọn ohun ọsin kuro ni fifa soke lakoko iṣẹ.
Ọja Pariview ati irinše
The Total Automatic Self-priming Jet Pump TWP415006 is designed for efficient water transfer. It includes a 24L cylindrical tank, pressure switch, pressure gauge, stainless steel hose, and brass 3-way connector.

Olusin 1: Pariview of the Total Automatic Self-priming Jet Pump TWP415006.

Figure 2: Key features of the pump, including 1500W power, 24L tank, and copper wire motor.
Awọn eroja to wa:
- 1 x Automatic Self-priming Jet Pump (1.5kW)
- 1 x 24L Cylindrical Tank
- 1 x Ipa Yipada
- 1 x Stainless Steel Hose
- 1 x Iwọn Ipa
- 1 x Brass 3-way Connector
Awọn pato
| Paramita | Iye |
|---|---|
| Awoṣe | TWP415006 |
| Voltage | 220-240V ~ 50Hz |
| Ti won won Agbara | 1500W (2.0HP) |
| Max. Sisan | 100 L/min |
| O pọju. Ori | 60m |
| Max. Suction | 9m |
| Pipe Opin | 1" x 1" |
| Motor Iru | Mẹ́ńtì Wáyà Ejò |
| Ohun elo Impeller | Irin ti ko njepata |
| Ara fifa | Electrophoresis |
| Ohun elo ọpa | Stainless Steel Welding (304+45#) |
| USB Ipari | 0.3m |
| Iwọn Nkan | 32 kilo |
| Package Mefa | 62.7 x 57.3 x 36 cm |
Ṣeto
1. Ifiweranṣẹ
- Choose a flat, stable, and dry location for the pump, protected from direct weather exposure.
- Rii daju pe fentilesonu to peye ni ayika fifa soke.
- Gbe fifa omi naa si ibi ti o sunmọ orisun omi bi o ti ṣee ṣe lati dinku gbigbe fifa omi.
2. Pipe Asopọ
- Ifa Pipe: Connect a rigid pipe of 1" diameter to the suction inlet. Ensure the suction pipe is airtight to prevent air leaks, which can affect priming and pump performance. Install a foot valve with a strainer at the end of the suction pipe in the water source to prevent debris from entering the pump and to maintain prime.
- Paipu Yiyọ: Connect a 1" diameter pipe to the discharge outlet. The included stainless steel hose and brass 3-way connector should be used for the pressure tank and pressure gauge connection.
- Use thread sealant tape on all threaded connections to ensure a watertight seal.
3. Asopọ Itanna
- Ensure the power supply is 220-240V~50Hz.
- Connect the pump to a dedicated, properly grounded electrical outlet.
- Do not use extension cords unless absolutely necessary, and if so, ensure they are rated for outdoor use and the pump's power requirements.
4. Ṣíṣe àtúnṣe Pọ́ọ̀pù
- Before first use, or if the pump has run dry, it must be primed.
- Locate the priming plug on the top of the pump casing.
- Remove the priming plug and slowly fill the pump casing with clean water until it overflows.
- Rọpo plug alakoko ni aabo.
- Ensure the discharge valve is open before starting the pump.
Awọn ilana Iṣiṣẹ
1. Bibẹrẹ Pump
- Ensure the pump is properly primed (see Setup section).
- Daju pe gbogbo awọn asopọ wa ni aabo ati laisi jijo.
- Plug the pump into the grounded electrical outlet. The pump will start automatically when pressure drops below the set point of the pressure switch.
2. Monitoring Operation
- Observe the pressure gauge to ensure the system is operating within expected pressure ranges.
- Fetí sílẹ̀ fún àwọn ìró tàbí ìgbọ̀nsẹ̀ tí kò wọ́pọ̀, èyí tí ó lè fi ìṣòro hàn.
- Check for any leaks around connections.
3. Títìpa
- To stop the pump, simply unplug it from the power source. The automatic pressure switch will also stop the pump when the desired pressure is reached.
- For extended periods of non-use, especially in freezing conditions, drain the pump and pipes completely to prevent damage.
Itoju
1. Awọn sọwedowo deede
- Periodically inspect the pump and all connections for signs of wear, damage, or leaks.
- Check the pressure tank's air charge annually. Refer to the tank's specific instructions for proper air pressure.
- Ensure the foot valve strainer is clear of debris.
2. Ninu
- Keep the pump exterior clean and free of dust and dirt to ensure proper cooling.
- Maṣe lo awọn kemikali lile tabi awọn afọmọ abrasive.
3. Winterization (for cold climates)
- If the pump is installed in an area subject to freezing temperatures, it must be drained completely to prevent damage from ice expansion.
- Disconnect power, open all drain plugs, and remove the priming plug to allow all water to escape.
- Store the pump in a warm, dry place if possible.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ | No power; tripped circuit breaker; faulty motor. | Check power connection and circuit breaker. Consult a qualified electrician if motor is suspected faulty. |
| Pọ́m̀pù ń ṣiṣẹ́ ṣùgbọ́n omi kò ṣàn | Pump not primed; air leak in suction line; clogged foot valve/strainer; low water level in source. | Re-prime the pump. Check all suction connections for leaks. Clean foot valve strainer. Ensure adequate water in source. |
| Low pressure or flow | Partial air leak; clogged impeller; worn components; incorrect pipe size. | Check suction line for small leaks. Inspect and clean impeller. Consult service for worn parts. Ensure correct pipe diameter. |
| Awọn iyipo fifa soke nigbagbogbo | Pressure tank air charge too low; leak in system; faulty pressure switch. | Check and adjust pressure tank air charge. Inspect entire system for leaks. Test or replace pressure switch. |
| Nmu ariwo / gbigbọn | Cavitation (air in pump); loose mounting; bearing wear. | Ensure pump is primed and no air leaks. Secure pump mounting. Consult service for bearing issues. |
Atilẹyin ọja ati Support
TOTAL products are manufactured to high-quality standards and are guaranteed against manufacturing defects. For warranty claims or technical support, please contact your local TOTAL authorized service center or the retailer from whom you purchased the product. Please retain your proof of purchase for warranty validation.
Fun iranlọwọ siwaju sii, o le ṣabẹwo si TOTAL Store on Amazon.