1. Ifihan
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.
2. Alaye Aabo
Awọn Itọsọna Aabo pataki:
- Installation and servicing must be performed by a qualified HVAC technician. Improper installation can result in electric shock, fire, or water leakage.
- Rii daju pe ẹyọ ti wa ni ilẹ daradara lati ṣe idiwọ mọnamọna itanna.
- Turn off all power to the unit before performing any maintenance or servicing.
- Do not block the air intake or outlet of the outdoor or indoor units.
- Use only specified refrigerants (R410A) and follow all environmental regulations.
- Pa awọn ọmọde ati awọn ẹranko mọ kuro ni ibi ti a fi n ṣiṣẹ ni ita gbangba.
3. Ọja Ipariview ati Awọn ẹya ara ẹrọ
The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.
Awọn ẹya pataki:
- Inverter AC Technology: Adjusts compressor speed for optimal temperature control, reduced energy consumption, and quieter operation.
- Multi-Positional Cased Coil: Factory-integrated TXV ensures efficient operation and flexibility in various installation configurations, enhancing HVAC performance.
- Iṣiṣẹ to gaju: 15.5 SEER2 rating for significant energy savings.
- Ikole ti o tọ: Features a Gold Fin condenser coil for enhanced corrosion resistance and longevity.
- Isẹ idakẹjẹ: Engineered for ultra-quiet performance, with a noise level of 56 dB.
- Awọn sensọ Smart: Integrated smart sensors for intelligent operation and performance monitoring.
- All-Climate Performance: Designed to operate effectively across a wide range of outdoor temperatures.
- Iwari ti o jo: System includes alerts for refrigerant leaks to prevent hazards.
Awọn eroja to wa:
The complete system includes the following components:
- Ita gbangba Condenser Unit
- Indoor Multi-Positional Evaporator Cased Coil
- Smart WiFi Thermostat
- 50' Insulated Line Set (3/8" LL x 3/4" SL x 3/8")
- 1/2" x 6' 10 Gauge Electrical Whip
- 60A Non-fused Disconnect Switch
- Controls Surge Protector
- CPS Charging Adapter
- Odi Sleeve
- Wall Mount akọmọ
- Afowoyi Olumulo (iwe-ipamọ yii)

Nọmba 3.1: Pariview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

Nọmba 3.2: Alaye view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

Nọmba 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.
4. Eto ati fifi sori
Ti beere fifi sori Ọjọgbọn: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.
Ilana fifi sori ẹrọ nigbagbogbo pẹlu:
- Aṣayan Aaye: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
- Mounting Units: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
- Isopọ laini firiji: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
- Asopọmọra Itanna: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
- Imujade Condensate: Installing proper drainage for the indoor evaporator coil.
- Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
- Fifi sori ẹrọ thermostat: Wiring and configuring the Smart WiFi Thermostat.
- Idanwo eto: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.
Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.
5. Awọn ilana Iṣiṣẹ
Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.
Smart WiFi Thermostat Operation:
The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:
- Aṣayan Ipo: Switch between cooling, fan-only, or off modes.
- Eto iwọn otutu: Adjust the desired indoor temperature.
- Iṣeto: Program daily or weekly temperature schedules for energy efficiency.
- Iṣakoso Iyara Fan: Adjust fan speed (if applicable).
- Asopọmọra: Connect to your home WiFi network for remote control via a smartphone app and integration with smart home systems (e.g., Alexa, Google Home, SmartThings, IFTTT).
- Abojuto ọriniinitutu: View indoor humidity levels.
- Ipo eto: Monitor current indoor temperature, cooling set point, and system operational status.

Nọmba 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.
For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.
6. Itọju
Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.
User Maintenance (Monthly/Quarterly):
- Clean or Replace Air Filters: Check and clean or replace the air filters in your indoor unit (or furnace/air handler, if applicable) monthly, or more frequently if the system is used heavily or in dusty environments. The system uses washable, reusable mesh filters.
- Ẹyọ ita gbangba ti o han gbangba: Ensure the outdoor condenser unit is free from debris, leaves, grass clippings, and other obstructions that could block airflow. Keep vegetation trimmed around the unit.
- Check Condensate Drain: Periodically check the condensate drain line for blockages. A clogged drain can cause water overflow.
Professional Maintenance (Annually):
It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:
- Cleaning of condenser and evaporator coils.
- Ṣiṣayẹwo awọn ipele refrigerant ati titẹ.
- Ṣíṣàyẹ̀wò àwọn ìsopọ̀ iná mànàmáná àti àwọn èròjà.
- Àwọn ẹ̀yà ara tí ń gbé nǹkan (tí ó bá yẹ).
- Ṣíṣàyẹ̀wò ìṣàtúnṣe thermostat.
- Ṣíṣe àyẹ̀wò àwọn ọ̀nà ìṣàn omi fún jíjò.
- Verifying proper system operation and performance.
7. Laasigbotitusita
Ṣaaju ki o to kan si onimọ-ẹrọ iṣẹ kan, tunview the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| System Not Cooling |
|
|
| Ailera Airflow |
|
|
| Awọn Ariwo Alailẹgbẹ |
|
|
| Water Leakage (Indoor Unit) |
|
|
If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.
8. Awọn pato
Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:
| Sipesifikesonu | Iye |
|---|---|
| Brand | ACIQ |
| Awọn nọmba awoṣe | ACiQ-48-AC / ACIQ-60-ACL / IKIC51 |
| Agbara | 4 Tons (48,000 BTU/h) |
| Ìṣiṣẹ́ (SEER2) | 15.5 SEER2 |
| Iru Refrigerant | R410A |
| Voltage | 230 Volts |
| Wattage | 4000 watt |
| Ariwo Ipele | 56 dB |
| Awọn iwọn Ita ita (D x W x H) | 16.14" x 37.24" x 52.48" |
| Indoor Coil Dimensions (W x D x H) | 24.49" x 20.98" x 27.99" (622 x 533 x 711 mm) |
| Iru fifi sori ẹrọ | Pin System |
| Fọọmù ifosiwewe | Central Split System |
| Àlẹmọ Iru | Washable, Reusable Mesh Filter |
| Pakà Area Ideri | Isunmọ 2400 Square Ẹsẹ |
| Pataki Awọn ẹya ara ẹrọ | Inverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance |

Nọmba 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Nọmba 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

Nọmba 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.
9. Atilẹyin ọja ati Support
Awọn ofin Atilẹyin ọja: The ACiQ system comes with a 7-odun awọn ẹya ara atilẹyin ọja ati a 12-odun konpireso atilẹyin ọja. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.
Atilẹyin Onibara: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official webaaye tabi iwe ti o wa pẹlu rira rẹ. O tun le ṣàbẹwò awọn ACiQ Store on Amazon fun alaye siwaju sii.





