Renogy RIV1230P2-126

Ìwé Ìtọ́ni fún Inverter Renogy 3000W 12V Pro Pure Sine Wave

Model: RIV1230P2-126

1. Ifihan

The Renogy 3000W 12V Pro Pure Sine Wave Inverter converts 12V DC battery power into stable 110V/120V AC household electricity. This inverter is designed for reliable performance in various applications, including RVs, trucks, and off-grid home energy systems. Key features include a 3000W continuous power output, 6000W peak power, built-in Bluetooth for monitoring, an EcoSleep mode for energy conservation, and a remote controller for convenient operation.

Renogy 3000W 12V Pro Pure Sine Wave Inverter with remote control and cable

Figure 1: Renogy 3000W 12V Pro Pure Sine Wave Inverter with included remote control and communication cable.

2. Alaye Aabo

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electrical shock, fire, or serious injury.

  • The inverter is UL 458 & CSA C22.2 No. 107.1 certified, ensuring compliance with safety and quality standards.
  • Ensure the inverter chassis is properly grounded to prevent electrical hazards.
  • The inverter features pre-charging functionality to ensure a smooth start, protecting both the battery and the inverter from high peak currents during connection.
  • Dual-polarity reverse connection protection is integrated to prevent internal damage in case of accidental misconnection of battery positive and negative terminals. However, always verify correct polarity before making connections.
  • Be aware that the surge capacity of inductive appliances can exceed their continuous rating by 5 to 7 times. Plan your loads accordingly to avoid unexpected shutdowns.
  • Do not expose the inverter to rain, moisture, or excessive dust.
  • Ṣiṣẹ ẹrọ oluyipada ni agbegbe ti o ni afẹfẹ daradara lati ṣe idiwọ igbona.
Diagram illustrating pre-charging and dual-polarity reverse protection features of the inverter

Figure 2: Inverter security features including pre-charging and dual-polarity reverse protection.

Renogy inverter with GFCI, FCC, and ETL certifications shown, with a boat in the background

Figure 3: Essential safety protections including GFCI, FCC, and ETL certifications.

3. Eto

3.1 Iṣagbesori

Mount the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure there is adequate space around the inverter for proper airflow and cooling.

3.2 DC Input Asopọ

Connect the inverter to your 12V battery bank. Use appropriate gauge cables for the power rating. The inverter is equipped with dual-polarity reverse connection protection, but it is crucial to always connect the positive (+) terminal of the inverter to the positive (+) terminal of the battery and the negative (-) terminal of the inverter to the negative (-) terminal of the battery. The pre-charging function will help protect the system during initial connection.

Person connecting battery cables to the inverter, highlighting reverse polarity protection

Figure 4: Connecting battery cables to the inverter, demonstrating reverse polarity protection.

3.3 AC o wu Asopọ

The inverter provides two standard AC sockets and one AC terminal block for connecting your AC loads. Ensure that the total continuous power draw of your appliances does not exceed 3000W. For permanent installations, use the AC terminal block following local electrical codes.

3.4 Remote Controller Connection

Connect the included 16.4ft wired remote controller to the designated port on the inverter. This allows for convenient power control and monitoring from a distance.

Renogy remote controller for the inverter

Figure 5: The Renogy wired remote controller.

4. Awọn ilana Iṣiṣẹ

4.1 Titan / Pa a

To power on the inverter, press the power button on the unit or the remote controller. The indicator lights will confirm operation. To power off, press the button again.

4.2 EcoSleep Mode

The intelligent EcoSleep mode conserves energy by automatically switching the inverter to a low-power sleep state when no load is detected. In this mode, idle power consumption is less than 10W. The inverter will automatically wake up when an AC load is connected or detected.

Renogy inverter with a smartphone displaying EcoSleep mode settings

Figure 6: Inverter operating in EcoSleep mode, showing smartphone monitoring interface.

Renogy inverter installed in an RV with EcoSleep mode indicator

Figure 7: Inverter in an RV setup, demonstrating EcoSleep mode activation.

4.3 Bluetooth Monitoring

The inverter features built-in Bluetooth connectivity, allowing for real-time monitoring via a compatible smartphone application. It also supports RV-C connectivity for seamless integration with Renogy One Core/M1 systems, providing enhanced control and convenience.

Smartphone screens displaying the Renogy inverter monitoring application

Figure 8: Real-time monitoring of the inverter via a smartphone application.

Diagram showing the inverter powering various RV appliances like TV, coffee maker, air conditioner, microwave, and portable freezer

Olusin 9: Example of RV appliances powered by the inverter.

5. Itọju

Itọju deede ṣe idaniloju igbesi aye gigun ati iṣẹ ti o dara julọ ti oluyipada rẹ.

  • Jẹ́ kí inverter náà mọ́ tónítóní kí ó má ​​sì sí eruku àti ìdọ̀tí. Lo aṣọ gbígbẹ fún fífọ.
  • Ensure all electrical connections, especially battery terminals, are tight and free from corrosion.
  • Verify that the ventilation openings are not blocked to allow for proper heat dissipation.
  • The inverter supports multiple battery types including GEL, AGM, SLA, FLD, and Lithium (LI). Ensure your battery settings are correctly configured if applicable.

6. Laasigbotitusita

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes or persistent problems, contact Renogy customer support.

  • Ko si Ijade agbara: Check battery connections for tightness and correct polarity. Verify battery voltage is within the inverter's operating range. Ensure the inverter is powered on.
  • Low AC Output Voltage: Ṣayẹwo DC input voltage from the battery. Ensure the load is not exceeding the inverter's continuous power rating.
  • Itọkasi apọju: Reduce the number of connected AC appliances. Disconnect high-power inductive loads that may cause surge spikes.
  • Igbóná púpọ̀: Ensure the inverter is in a well-ventilated area. Clear any obstructions from the cooling fans. Reduce the load if operating in high ambient temperatures.

7. Awọn pato

Ẹya ara ẹrọSipesifikesonu
Orukọ awoṣe3000W Pure Sine Wave Inverter Pro
Nọmba Awoṣe NkanRIV1230P2-126
Tesiwaju Power wu3000W
Ijade agbara ti o ga julọ6000W
DC Input Voltage12V
AC wu Voltage110V/120V
Imudara IyipadaTiti di 90%
Ni kikun-fifuye ṣiṣeExceeding 87%
Idle Power Consumption (EcoSleep Mode)<10W
Lapapọ Idarudapọ ti irẹpọ (THD)<2%
Awọn Socket AC2
AC ebute Block1
Remote Controller Cable Length16.4 ft
Awọn iwọn Ọja (L x W x H)19.5 x 9.2 x 4.2 inches
Iwọn Nkan16.6 iwon
Awọn iwe-ẹriUL 458, CSA C22.2 No. 107.1, FCC, ETL
Diagram showing the dimensions of the Renogy 3000W Pure Sine Wave Inverter Pro

Figure 10: Inverter dimensions.

Comparison table of Renogy P2 PRO Series vs. Renogy P2 Series inverters

Figure 11: Feature comparison between Renogy P2 PRO Series and P2 Series inverters.

8. Atilẹyin ọja ati Support

8.1 atilẹyin ọja

The Renogy 3000W 12V Pro Pure Sine Wave Inverter comes with a 3-year warranty. For any issues encountered within this period, please contact Renogy customer support.

8.2 Onibara Support

Renogy is committed to providing excellent customer service. Support includes:

  • 24-hour prompt response to inquiries.
  • Access to local warehouses in the US for efficient service.
  • Professional technical guidance to assist with installation, operation, and troubleshooting.
Icons representing Renogy customer support features: 24-hour response, local warehouses, professional technical guidance, and 15 years of experience

Figure 12: Renogy customer support services.

Awọn iwe aṣẹ ti o jọmọ - RIV1230P2-126

Ṣaajuview Renogy RIV1230P2-126 Pro 3000W 12V Pure Sine Wave Inverter User Manual
Comprehensive user manual for the Renogy RIV1230P2-126 Pro 3000W 12V Pure Sine Wave Inverter with EcoSleep Mode, covering features, specifications, installation, operation, and safety guidelines.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Renogy 3000W 12V Pro Pure Sine Wave Inverter
Ìwé ìtọ́ni tó péye fún Renogy 3000W 12V Pro Pure Sine Wave Inverter, àlàyé nípa fífi sori ẹrọ, iṣẹ́, àwọn ìlànà ààbò, àwọn ìlànà pàtó, àti ìṣòro. Ó ní ipò EcoSleep fún agbára ṣíṣe.
Ṣaajuview Ilana olumulo Renogy 12V 3000W Pro Pure Sine Wave Inverter
Itọsọna olumulo fun Renogy 12V 3000W Pro Pure Sine Wave Inverter, pese iṣẹ pataki, itọju, ati alaye ailewu. Kọ ẹkọ nipa awọn ẹya ara ẹrọ ọja, awọn idasile, ati awọn aami-iṣowo.
Ṣaajuview Renogy 12V Pure Sine Wave Inverter pẹlu Itọsọna Olumulo Gbigbe Yipada
Ìwé ìtọ́ni yìí fún àwọn ìlànà tó péye fún Renogy 12V Pure Sine Wave Inverter pẹ̀lú Transfer Switch, tó wà ní àwọn àwòṣe 1000W, 2000W, àti 3000W. Ó ní àwọn ìlànà tó ń fi sori ẹ̀rọ, iṣẹ́, àwọn ìlànà ààbò, ìṣòro, àti àwọn ìlànà ìmọ̀ ẹ̀rọ fún àwọn ohun èlò tí kò ní ààrin ẹ̀rọ.
Ṣaajuview Renogy 12V Pure Sine Wave Inverter Core Series - Awọn pato Imọ-ẹrọ ati Awọn ẹya
Ṣawari Renogy 12V Pure Sine Wave Inverter Core Series, ti o nfihan iyipada agbara daradara, iṣẹ idakẹjẹ, ati awọn ẹya aabo ilọsiwaju. Apẹrẹ fun pipa-akoj awọn ọna šiše. Pẹlu awọn alaye imọ-ẹrọ fun RIV1210PU-126, RIV1220PU-126, ati awọn awoṣe RIV1230PU-126.
Ṣaajuview Renogy 12V Pure Sine Wave Inverter pẹlu Itọsọna Olumulo Gbigbe Yipada
Ìwé ìtọ́ni tó péye fún àwọn Inverters Renogy 12V Pure Sine Wave (1000W, 2000W, 3000W) pẹ̀lú Transfer Switch, tó bo ìfisílé, iṣẹ́, ààbò, ìṣòro, àti àwọn ìlànà pàtó.